Pilot study on accuracy and dimensional stability of impression materials using industrial CT technology.

Stefanie Steinhäuser-Andresen1, Andreas Detterbeck, Christoph Funk, Michael Krumm, Stefan Kasperl, Alexandra Holst, Ursula Hirschfelder.   

Abstract

OBJECTIVE: Using computed tomography, scan impressions can be saved and edited as virtual data. The aim of this study was to evaluate the parameters influencing different impression materials and impression trays and their relevance with regard to accuracy and dimensional stability.
MATERIALS AND METHODS: Two alginate impressions (Zhermack Hydrogum®5 and Kaniedenta Tetrachrom®) and a polyether impression (3MEspe Impregum™) were each combined with two acrylic trays (3M Espe Position Tray™ and Profimed Opti-Tray) and CT scanned immediately after impression at the Fraunhofer Institute Development Center for X-ray Technology (EZRT) in Fürth, Germany. Each impression was digitized 10 times on the same day, 3 times after 2 days and twice after 6 days, thus determining the dimensional stability of the various materials. An acrylic model was digitized with a high-resolution µCT research scanner to be used as a reference for assessing the accuracy of the impression materials. For graphic and statistical analysis, VGStudio Max® was used.
RESULTS: Both alginate impressions were less dimensionally stable than the polyether impression material. The Zhermack Hydrogum®5 alginate impression resulted in more deviation (151 µm) after 6 days than the Kaniedenta Tetrachrom® impression. The polyether scans showed a mean deviation of 73 µm. The accuracy of both alginates was similarly precise (mean value: Hydrogum®5 0.129 ± 0.021 mm, Tetrachrom® 0.137 ± 0.002 mm). The type of tray had limited influence on the results of the alginate impressions, while the accuracy of the Impregum™ impression depended on the tray combination chosen.
CONCLUSION: The accuracy of the alginate impressions is sufficient for clinical use in orthodontics and produced, with correct storage, acceptable results even after 2 days. Hydrogum®5 impressions proved to be slightly more accurate than the reference material but less dimensionally stable than the Tetrachrom® impressions. The 3M Espe Position Tray™ seemed to be more practical due to a better retentive effect compared to the Opti-Tray made by Profimed.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21503851     DOI: 10.1007/s00056-011-0015-6

Source DB:  PubMed          Journal:  J Orofac Orthop        ISSN: 1434-5293            Impact factor:   1.938


  25 in total

1.  Validity, reliability, and reproducibility of plaster vs digital study models: comparison of peer assessment rating and Bolton analysis and their constituent measurements.

Authors:  Daron R Stevens; Carlos Flores-Mir; Brian Nebbe; Donald W Raboud; Giseon Heo; Paul W Major
Journal:  Am J Orthod Dentofacial Orthop       Date:  2006-06       Impact factor: 2.650

2.  Influence of impression material and time on the 3-dimensional accuracy of implant impressions.

Authors:  Stefan Holst; Markus B Blatz; Michael Bergler; Matthias Goellner; Manfred Wichmann
Journal:  Quintessence Int       Date:  2007-01       Impact factor: 1.677

3.  Comparison of the spatial landmark scatter of various 3D digitalization methods.

Authors:  Florian Boldt; Christian Weinzierl; Klaus Hertrich; Ursula Hirschfelder
Journal:  J Orofac Orthop       Date:  2009-05-31       Impact factor: 1.938

4.  3D morphological measurements of dental casts with occlusal relationship using microfocus X-ray CT.

Authors:  Masayuki Kamegawa; Masayuki Nakamura; Sadami Tsutsumi
Journal:  Dent Mater J       Date:  2008-07       Impact factor: 2.102

5.  A new system for scanning, measuring and analyzing dental casts based on a 3D holographic sensor.

Authors:  M Redlich; T Weinstock; Y Abed; R Schneor; Y Holdstein; A Fischer
Journal:  Orthod Craniofac Res       Date:  2008-05       Impact factor: 1.826

6.  Evaluation of impacted canines by means of computerized tomography.

Authors:  J N Elefteriadis; A E Athanasiou
Journal:  Int J Adult Orthodon Orthognath Surg       Date:  1996

7.  Dimensional accuracy of a new polyether impression material.

Authors:  Tatsuo Endo; Werner J Finger
Journal:  Quintessence Int       Date:  2006-01       Impact factor: 1.677

8.  Effect of storage time on the accuracy of casts made from different irreversible hydrocolloids.

Authors:  Maurizio Sedda; Andrea Casarotto; Aune Raustia; Andrea Borracchini
Journal:  J Contemp Dent Pract       Date:  2008-05-01

9.  The relationship between digital model accuracy and time-dependent deformation of alginate impressions.

Authors:  Toros Alcan; Cenk Ceylanoğlu; Bekir Baysal
Journal:  Angle Orthod       Date:  2009-01       Impact factor: 2.079

10.  Technique comparison for efficient orthodontic tooth measurements using digital models.

Authors:  Heather M I Horton; James R Miller; Philippe R Gaillard; Brent E Larson
Journal:  Angle Orthod       Date:  2010-03       Impact factor: 2.079

View more
  10 in total

1.  Optical 3D scans for orthodontic diagnostics performed on full-arch impressions. Completeness of surface structure representation.

Authors:  Annike B Vogel; Fatih Kilic; Falko Schmidt; Sebastian Rübel; Bernd G Lapatki
Journal:  J Orofac Orthop       Date:  2015-11       Impact factor: 1.938

2.  Digital 3D image of bimaxillary casts connected by a vestibular scan.

Authors:  Susanne Wriedt; Irene Schmidtmann; Mareike Niemann; Heinrich Wehrbein
Journal:  J Orofac Orthop       Date:  2013-06-28       Impact factor: 1.938

3.  Accuracy of digital models obtained by direct and indirect data capturing.

Authors:  Jan-Frederik Güth; Christine Keul; Michael Stimmelmayr; Florian Beuer; Daniel Edelhoff
Journal:  Clin Oral Investig       Date:  2012-07-31       Impact factor: 3.573

4.  Dimensional accuracy of jaw scans performed on alginate impressions or stone models: A practice-oriented study.

Authors:  Annike B Vogel; Fatih Kilic; Falko Schmidt; Sebastian Rübel; Bernd G Lapatki
Journal:  J Orofac Orthop       Date:  2015-07       Impact factor: 1.938

5.  Dimensional accuracy of cone beam CT with varying angulation of the jaw to the X-ray beam.

Authors:  George K Koch; Adam Hamilton; Kelly Wang; Laura Herschdorfer; Kyu Ha Lee; German O Gallucci; Bernard Friedland
Journal:  Dentomaxillofac Radiol       Date:  2018-11-08       Impact factor: 2.419

6.  Accuracy of Digital Impressions and Fitness of Single Crowns Based on Digital Impressions.

Authors:  Xin Yang; Pin Lv; Yihong Liu; Wenjie Si; Hailan Feng
Journal:  Materials (Basel)       Date:  2015-06-29       Impact factor: 3.623

7.  Clinical Evaluation of Time Efficiency and Fit Accuracy of Lithium Disilicate Single Crowns between Conventional and Digital Impression.

Authors:  Ji-Su Park; Young-Jun Lim; Bongju Kim; Myung-Joo Kim; Ho-Beom Kwon
Journal:  Materials (Basel)       Date:  2020-11-30       Impact factor: 3.623

8.  Effect of posterior span length on the trueness and precision of 3 intraoral digital scanners: A comparative 3-dimensional in vitro study.

Authors:  Mohamed Fattouh; Laila Mohamed Mohamed Kenawi; Hesham Fattouh
Journal:  Imaging Sci Dent       Date:  2021-08-11

9.  Comparison and evaluation of the morphology of crowns generated by biogeneric design technique with CEREC chairside system.

Authors:  Fang Wang; Qingqing Tang; Shuang Xi; Ruirui Liu; Lin Niu
Journal:  PLoS One       Date:  2020-01-16       Impact factor: 3.240

10.  Impression material accuracy for palatal orthodontic miniscrews.

Authors:  Natalie Schenz; Vincent Schwarz; Romed Hörmann; Adriano G Crismani
Journal:  J Orofac Orthop       Date:  2020-09-08       Impact factor: 1.938

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.