Literature DB >> 17216911

Influence of impression material and time on the 3-dimensional accuracy of implant impressions.

Stefan Holst1, Markus B Blatz, Michael Bergler, Matthias Goellner, Manfred Wichmann.   

Abstract

OBJECTIVE: To investigate, in vitro, the effect of time on the 3-dimensional accuracy of open-tray implant impression copings made of polyvinyl siloxane and polyether impression materials. METHOD AND MATERIALS: Reference models with 4 internal connection implants were fabricated. Four sets of 71 direct impressions were made with square impression copings using an open-tray technique. One set of impressions was made with polyether material (material A) and each of 3 polyvinyl siloxane materials (materials B, C, and D). Three-dimensional changes in spatial orientation of the implant analogs were measured over 48 hours using an optical measurement device. Deviation values were summed over 4 points and averaged per impression. Global differences were tested with a nonparametric Kruskal-Wallis test followed by pairwise comparisons using the Mann-Whitney U test.
RESULTS: The mean dimensional accuracy of implant impressions significantly differed over time (P < .001). Materials A and B were found to produce comparable results, For materials C and D there was a significant increase in deviations, with a maximum increase at 2 hours. Deviations for material C were comparable to materials A and B at 48 hours. Baseline values were not maintained by any material.
CONCLUSIONS: Within the limits of this in vitro study, it can be concluded that time cannot be neglected as a factor affecting the accuracy of implant master casts.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17216911

Source DB:  PubMed          Journal:  Quintessence Int        ISSN: 0033-6572            Impact factor:   1.677


  9 in total

1.  Pilot study on accuracy and dimensional stability of impression materials using industrial CT technology.

Authors:  Stefanie Steinhäuser-Andresen; Andreas Detterbeck; Christoph Funk; Michael Krumm; Stefan Kasperl; Alexandra Holst; Ursula Hirschfelder
Journal:  J Orofac Orthop       Date:  2011-03       Impact factor: 1.938

2.  Comparison of the accuracy of intraoral digital impression system and conventional impression techniques for multiple implants in the full-arch edentulous mandible.

Authors:  Firas-Abdulameer Farhan; Ali-Jameel-Abdul Sahib; Abdalbseet-Ahmad Fatalla
Journal:  J Clin Exp Dent       Date:  2021-05-01

3.  Effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts.

Authors:  Behnaz Ebadian; Mansor Rismanchian; Badrosadat Dastgheib; Farshad Bajoghli
Journal:  Dent Res J (Isfahan)       Date:  2015 Mar-Apr

4.  Impact of design and length on the accuracy of closed tray transfer copings.

Authors:  Elena Roig; Natalia Álvarez-Maldonado; Luis-Carlos Garza; Marta Vallés; José Espona; Miguel Roig
Journal:  J Clin Exp Dent       Date:  2019-08-01

5.  Dimensional accuracy of stone casts obtained with multiple pours into the same mold.

Authors:  Valdimar da Silva Valente; Artêmio Luiz Zanetti; Pedro Paulo Feltrin; Ricardo Tatsuo Inoue; Carmem Dolores Vilarinho Soares de Moura; Luiz Evaldo de Moura Pádua
Journal:  ISRN Dent       Date:  2012-12-24

6.  Accuracy of different impression materials in parallel and nonparallel implants.

Authors:  Mahroo Vojdani; Kianoosh Torabi; Elham Ansarifard
Journal:  Dent Res J (Isfahan)       Date:  2015 Jul-Aug

7.  Comparison of Dimensional Accuracy between Open-Tray and Closed-Tray Implant Impression Technique in 15° Angled Implants.

Authors:  F Balouch; E Jalalian; M Nikkheslat; R Ghavamian; Sh Toopchi; F Jallalian; S Jalalian
Journal:  J Dent (Shiraz)       Date:  2013-09

8.  Cast accuracy obtained from different impression techniques at different implant angulations (in vitro study).

Authors:  Enas A Elshenawy; Ahmed M Alam-Eldein; Fadel A Abd Elfatah
Journal:  Int J Implant Dent       Date:  2018-03-20

9.  Impression material accuracy for palatal orthodontic miniscrews.

Authors:  Natalie Schenz; Vincent Schwarz; Romed Hörmann; Adriano G Crismani
Journal:  J Orofac Orthop       Date:  2020-09-08       Impact factor: 1.938

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.