Literature DB >> 18833768

3D morphological measurements of dental casts with occlusal relationship using microfocus X-ray CT.

Masayuki Kamegawa1, Masayuki Nakamura, Sadami Tsutsumi.   

Abstract

In the diagnosis of dental occlusion, it is necessary to quantitatively measure interocclusal contacts and transfer them to a computer model. In this aspect, three-dimensional computer models of upper and lower dental casts play a significant role. In this study, we proposed a new method to measure occlusal interaction by using a microfocus X-ray CT technique. Measurement accuracy was determined as +/-0.03 mm in comparison with a coordinate measuring machine. A superimposition procedure for two sets of three-dimensional dental cast models was also established. Using the same dental cast, the standard deviation between the two sets of models was +/-0.015 mm - which was defined as measurement precision. Between an optical laser scanner and the microfocus X-ray CT system, the standard deviation measured between the two models was +/-0.05 mm. Data were acquired when upper and lower dental casts mounted on the bite impression were scanned, and then occlusal interaction, contacts, and distance distribution between the casts were visualized by a colored map on the cast models. Within the limitations of the current study, it was successfully demonstrated that microfocus Xray CT was well poised for quantitative measurement of occlusal interaction.

Mesh:

Year:  2008        PMID: 18833768     DOI: 10.4012/dmj.27.549

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  3 in total

1.  Digital 3D image of bimaxillary casts connected by a vestibular scan.

Authors:  Susanne Wriedt; Irene Schmidtmann; Mareike Niemann; Heinrich Wehrbein
Journal:  J Orofac Orthop       Date:  2013-06-28       Impact factor: 1.938

2.  Pilot study on accuracy and dimensional stability of impression materials using industrial CT technology.

Authors:  Stefanie Steinhäuser-Andresen; Andreas Detterbeck; Christoph Funk; Michael Krumm; Stefan Kasperl; Alexandra Holst; Ursula Hirschfelder
Journal:  J Orofac Orthop       Date:  2011-03       Impact factor: 1.938

3.  Investigation of the effects of storage time on the dimensional accuracy of impression materials using cone beam computed tomography.

Authors:  Murat Alkurt; Zeynep Yeşıl Duymus; Numan Dedeoglu
Journal:  J Adv Prosthodont       Date:  2016-10-21       Impact factor: 1.904

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.