Literature DB >> 18416750

A new system for scanning, measuring and analyzing dental casts based on a 3D holographic sensor.

M Redlich1, T Weinstock, Y Abed, R Schneor, Y Holdstein, A Fischer.   

Abstract

OBJECTIVES: To evaluate the reliability of a new technique for measuring 3D-scanned orthodontic cast models with cross-section planes using teledent, a new software, developed at Technion - for the purpose of this research. EXPERIMENTAL VARIABLE: Thirty orthodontic plaster models were divided into three equal groups according to severity of teeth crowding. Measurements of mesio-distal tooth width and the arch length were performed manually on the casts using a conventional caliper. Thereafter, the models were scanned and processed into the software using a 3-D measuring scanner with a holographic sensor 'ConoProbe' (by Optimet, Jerusalem, Israel). teledent used two types of digital measurements; linear and cross-section planes to perform a space analysis on the scanned teeth. Significance was determined by the paired Wilcoxon rank sum test.
RESULTS: Results show that 3D measurements of tooth width and arch length obtained by cross-section planes were generally similar to manual caliper measurements, while linear measurements were statistically smaller. When comparing space analysis, both digital measurements were statistically smaller than the caliper (p < 0.05). The difference in space analysis between the caliper and the cross-section plane measurements was very small (0.38-0.74 mm) and can be considered clinically acceptable. However, a difference of 1.19-3 mm between the linear measurements and the caliper might have clinical implications especially in severely crowded dentition.
CONCLUSIONS: This study suggests that measurements performed by cross-section planes are as accurate as the manual caliper and can be employed clinically while the accuracy of linear measurements is sometimes questionable.

Entities:  

Mesh:

Year:  2008        PMID: 18416750     DOI: 10.1111/j.1601-6343.2007.00417.x

Source DB:  PubMed          Journal:  Orthod Craniofac Res        ISSN: 1601-6335            Impact factor:   1.826


  17 in total

1.  Multibracket appliance: impression defaults and their reduction by blocking-out  -  a three-dimensional study.

Authors:  Susanne Wriedt; Moritz Foersch; Jan Daniel Muhle; Irene Schmidtmann; Heinrich Wehrbein
Journal:  Clin Oral Investig       Date:  2015-06-24       Impact factor: 3.573

Review 2.  Accuracy and reproducibility of dental measurements on tomographic digital models: a systematic review and meta-analysis.

Authors:  Jamille B Ferreira; Ilana O Christovam; David S Alencar; Andréa F J da Motta; Claudia T Mattos; Adriana Cury-Saramago
Journal:  Dentomaxillofac Radiol       Date:  2017-04-26       Impact factor: 2.419

3.  Dose- and time-dependent effects of clodronate on orthodontic tooth movement.

Authors:  Enita Nakaš; Tomislav Lauc; Alisa Tiro; Vildana Džemidžić; Amila Zukanović; Miljenko Franić; Vladimir Ivković
Journal:  Bosn J Basic Med Sci       Date:  2017-02-21       Impact factor: 3.363

4.  [Fabrication and accuracy research on 3D printing dental model based on cone beam computed tomography digital modeling].

Authors:  Hui-Rong Zhang; Le-Feng Yin; Yan-Li Liu; Li-Yi Yan; Ning Wang; Gang Liu; Xiao-Li An; Bin Liu
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2018-04-01

5.  Comparison of orthodontic measurements on dental plaster casts and 3D scans.

Authors:  Johanna Radeke; Cynthia von der Wense; Bernd G Lapatki
Journal:  J Orofac Orthop       Date:  2014-07-06       Impact factor: 1.938

6.  Comparison of clinical bracket point registration with 3D laser scanner and coordinate measuring machine.

Authors:  Mahtab Nouri; Arash Farzan; Ali Reza Akbarzadeh Baghban; Reza Massudi
Journal:  Dental Press J Orthod       Date:  2015 Jan-Feb

7.  Dimensional accuracy of jaw scans performed on alginate impressions or stone models: A practice-oriented study.

Authors:  Annike B Vogel; Fatih Kilic; Falko Schmidt; Sebastian Rübel; Bernd G Lapatki
Journal:  J Orofac Orthop       Date:  2015-07       Impact factor: 1.938

8.  Pilot study on accuracy and dimensional stability of impression materials using industrial CT technology.

Authors:  Stefanie Steinhäuser-Andresen; Andreas Detterbeck; Christoph Funk; Michael Krumm; Stefan Kasperl; Alexandra Holst; Ursula Hirschfelder
Journal:  J Orofac Orthop       Date:  2011-03       Impact factor: 1.938

9.  Reliability of Bolton analysis evaluation in tridimensional virtual models.

Authors:  Marianna Mendonca Brandão; Marcio Costal Sobral; Carlos Jorge Vogel
Journal:  Dental Press J Orthod       Date:  2015-10

Review 10.  Linear measurements using virtual study models.

Authors:  Nghe S Luu; Liliya G Nikolcheva; Jean-Marc Retrouvey; Carlos Flores-Mir; Tarek El-Bialy; Jason P Carey; Paul W Major
Journal:  Angle Orthod       Date:  2012-04-24       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.