Literature DB >> 18473028

Effect of storage time on the accuracy of casts made from different irreversible hydrocolloids.

Maurizio Sedda1, Andrea Casarotto, Aune Raustia, Andrea Borracchini.   

Abstract

AIM: Several new irreversible hydrocolloid formulations have recently become available with claims of an improved dimensional stability by the manufacturers. The aim of this study was to evaluate the accuracy of casts made from alginate impression materials poured immediately and after specific storage periods. METHODS AND MATERIALS: Five alginates were tested: CA 37 (Cavex); Jeltrate (Dentsply Caulk); Jeltrate Plus (Dentsply Latin America); Hydrogum 5 (Zhermack); and Alginoplast (Heraeus Kulzer). A master model was mounted on a special device and used to obtain the impressions. These impressions were stored at 23 degrees C and 100% relative humidity, then poured with gypsum immediately, and again after 24, 72 and 120 hours. The casts were measured and the data were analyzed by one way analysis of variance (ANOVA) and Tukey test at p<0.05.
RESULTS: The dimensional stability of the alginate impressions was both material and time dependent (p<0.05). After 24 hours of storage, only Alginoplast and Hydrogum 5 comply with the master model (p>0.05). After 72 and 120 hours, only Hydrogum 5 was dimensionally stable (p>0.05).
CONCLUSION: The dimensional stability of the alginate impressions is influenced by the selected material and the storage time. CLINICAL SIGNIFICANCE: Alginate impressions should generally be poured immediately. However, some new types of alginate may have the pouring delayed.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18473028

Source DB:  PubMed          Journal:  J Contemp Dent Pract        ISSN: 1526-3711


  13 in total

1.  Dimensional Changes of Alginate Dental Impression Materials-An Invitro Study.

Authors:  Manisha M Kulkarni; Ram U Thombare
Journal:  J Clin Diagn Res       Date:  2015-08-01

2.  Pilot study on accuracy and dimensional stability of impression materials using industrial CT technology.

Authors:  Stefanie Steinhäuser-Andresen; Andreas Detterbeck; Christoph Funk; Michael Krumm; Stefan Kasperl; Alexandra Holst; Ursula Hirschfelder
Journal:  J Orofac Orthop       Date:  2011-03       Impact factor: 1.938

3.  Dimensional change over time of extended-storage alginate impression materials.

Authors:  Mary P Walker; Jason Burckhard; David A Mitts; Karen B Williams
Journal:  Angle Orthod       Date:  2010-11       Impact factor: 2.079

4.  The accuracy of gypsum casts obtained from the disinfected extended-pour alginate impressions through prolonged storage times.

Authors:  Rania A Sharif; Khalid M Abdelaziz; Najla M Alshahrani; Fatimah S Almutairi; Mohrah A Alaseri; Hoda L Abouzeid; Mohamed F A Elagib
Journal:  BMC Oral Health       Date:  2021-06-09       Impact factor: 2.757

5.  The effect of pouring time on the dimensional accuracy of casts made from different irreversible hydrocolloid impression materials.

Authors:  Supneet Singh Wadhwa; Richa Mehta; Nidhi Duggal; Kamlesh Vasudeva
Journal:  Contemp Clin Dent       Date:  2013-07

6.  Effect of storage time of extended-pour and conventional alginate impressions on dimensional accuracy of casts.

Authors:  Ahmad Rohanian; Ghasem Ommati Shabestari; Somayeh Zeighami; Mohammad Javad Samadi; Ahmad Reza Shamshiri
Journal:  J Dent (Tehran)       Date:  2014-11-30

7.  Effect of Storage Period on Dimensional Stability of Alginplus and Hydrogum 5.

Authors:  Shima Aalaei; Rohollah Ganj-Khanloo; Fatemeh Gholami
Journal:  J Dent (Tehran)       Date:  2017-01

8.  Characterization of morphology and composition of inorganic fillers in dental alginates.

Authors:  Ricardo Danil Guiraldo; Sandrine Bittencourt Berger; Rafael Leonardo Xediek Consani; Simonides Consani; Rodrigo Varella de Carvalho; Murilo Baena Lopes; Luciana Lira Meneghel; Fabiane Borges da Silva; Mário Alexandre Coelho Sinhoreti
Journal:  Biomed Res Int       Date:  2014-07-24       Impact factor: 3.411

9.  Investigation of the effects of storage time on the dimensional accuracy of impression materials using cone beam computed tomography.

Authors:  Murat Alkurt; Zeynep Yeşıl Duymus; Numan Dedeoglu
Journal:  J Adv Prosthodont       Date:  2016-10-21       Impact factor: 1.904

10.  Evaluation of dimensional accuracy for different complete edentulous impressions immersed in different disinfectant solutions.

Authors:  Hussein Abdelfattah Ismail; Hamada Z Mahross; Suaad Shikho
Journal:  Eur J Dent       Date:  2017 Apr-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.