Literature DB >> 21500258

Fast measurement of blood T1 in the human jugular vein at 3 Tesla.

Qin Qin1, John J Strouse, Peter C M van Zijl.   

Abstract

Current T(1) values for blood at 3T largely came from in vitro studies on animal blood or freshly drawn human blood. Measurement of blood T(1) in vivo could provide more specific information, e.g., for individuals with abnormal blood composition. Here, blood T(1) at 3T was measured rapidly (<1 min) in the internal jugular vein using a fast inversion-recovery technique in which multiple inversion time can be acquired rapidly due to constant refreshing of blood. Multishot EPI acquisition with flow compensation yielded high resolution images with minimum partial volume effect. Results showed T(1) = 1852 ± 104 msec among 24 healthy adults, a value higher than for bovine blood phantoms (1584 msec at Hct of 42%). A second finding was that of a significant difference (P < 0.01) between men and women, namely T(1) = 1780 ± 89 msec (n = 12) and T(1) = 1924 ± 58 msec (n = 12), respectively. This difference in normal subjects is tentatively explained by the difference in Hct between genders. Interestingly, however, studies done on sickle cell anemia patients with much lower Hct (23 ± 3%, n = 10) revealed similar venous blood T(1) = 1924 ± 82 msec, indicating other possible physical influences affecting blood T(1).
Copyright © 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21500258      PMCID: PMC3112465          DOI: 10.1002/mrm.22723

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  29 in total

1.  Improved accuracy and consistency in T1 measurement of flowing blood by using inversion recovery GE-EPI.

Authors:  Jun-Yu Guo; Seong-Eun Kim; D L Parker; E K Jeong; Ling Zhang; R B Roemer
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

2.  T1, T2 relaxation and magnetization transfer in tissue at 3T.

Authors:  Greg J Stanisz; Ewa E Odrobina; Joseph Pun; Michael Escaravage; Simon J Graham; Michael J Bronskill; R Mark Henkelman
Journal:  Magn Reson Med       Date:  2005-09       Impact factor: 4.668

3.  Inverse correlation between cerebral blood flow measured by continuous arterial spin-labeling (CASL) MRI and neurocognitive function in children with sickle cell anemia (SCA).

Authors:  John J Strouse; Christiane S Cox; Elias R Melhem; Hanzhang Lu; Michael A Kraut; Alexander Razumovsky; Kaleb Yohay; Peter C van Zijl; James F Casella
Journal:  Blood       Date:  2006-03-14       Impact factor: 22.113

4.  Oxygenation and hematocrit dependence of transverse relaxation rates of blood at 3T.

Authors:  Jason M Zhao; Chekesha S Clingman; M Johanna Närväinen; Risto A Kauppinen; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2007-09       Impact factor: 4.668

5.  Anatomical variation of cerebral venous drainage: the theoretical effect on jugular bulb blood samples.

Authors:  S C Beards; S Yule; A Kassner; A Jackson
Journal:  Anaesthesia       Date:  1998-07       Impact factor: 6.955

6.  A general kinetic model for quantitative perfusion imaging with arterial spin labeling.

Authors:  R B Buxton; L R Frank; E C Wong; B Siewert; S Warach; R R Edelman
Journal:  Magn Reson Med       Date:  1998-09       Impact factor: 4.668

7.  Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivo.

Authors:  William D Rooney; Glyn Johnson; Xin Li; Eric R Cohen; Seong-Gi Kim; Kamil Ugurbil; Charles S Springer
Journal:  Magn Reson Med       Date:  2007-02       Impact factor: 4.668

8.  Inhaled nitric oxide augments nitric oxide transport on sickle cell hemoglobin without affecting oxygen affinity.

Authors:  M T Gladwin; A N Schechter; J H Shelhamer; L K Pannell; D A Conway; B W Hrinczenko; J S Nichols; M E Pease-Fye; C T Noguchi; G P Rodgers; F P Ognibene
Journal:  J Clin Invest       Date:  1999-10       Impact factor: 14.808

9.  Methaemoglobin production in normal adults inhaling low concentrations of nitric oxide.

Authors:  J D Young; O Dyar; L Xiong; S Howell
Journal:  Intensive Care Med       Date:  1994-11       Impact factor: 17.440

Review 10.  Diffusional water permeability of mammalian red blood cells.

Authors:  G Benga; T Borza
Journal:  Comp Biochem Physiol B Biochem Mol Biol       Date:  1995-12       Impact factor: 2.231

View more
  25 in total

1.  Accuracy of Parenchymal Cerebral Blood Flow Measurements Using Pseudocontinuous Arterial Spin-Labeling in Healthy Volunteers.

Authors:  K Ambarki; A Wåhlin; L Zarrinkoob; R Wirestam; J Petr; J Malm; A Eklund
Journal:  AJNR Am J Neuroradiol       Date:  2015-08-06       Impact factor: 3.825

2.  Fast measurement of blood T1 in the human carotid artery at 3T: Accuracy, precision, and reproducibility.

Authors:  Wenbo Li; Peiying Liu; Hanzhang Lu; John J Strouse; Peter C M van Zijl; Qin Qin
Journal:  Magn Reson Med       Date:  2016-07-20       Impact factor: 4.668

3.  Cerebral blood volume mapping using Fourier-transform-based velocity-selective saturation pulse trains.

Authors:  Qin Qin; Yaoming Qu; Wenbo Li; Dapeng Liu; Taehoon Shin; Yansong Zhao; Doris D Lin; Peter C M van Zijl; Zhibo Wen
Journal:  Magn Reson Med       Date:  2019-02-08       Impact factor: 4.668

4.  Non-contrast-enhanced abdominal MRA at 3 T using velocity-selective pulse trains.

Authors:  Dan Zhu; Wenbo Li; Dapeng Liu; Guanshu Liu; Yigang Pei; Taehoon Shin; Farzad Sedaghat; Qin Qin
Journal:  Magn Reson Med       Date:  2020-02-04       Impact factor: 4.668

5.  Quantitative measurement of cerebral blood volume using velocity-selective pulse trains.

Authors:  Dexiang Liu; Feng Xu; Doris D Lin; Peter C M van Zijl; Qin Qin
Journal:  Magn Reson Med       Date:  2016-10-31       Impact factor: 4.668

6.  Improved velocity-selective-inversion arterial spin labeling for cerebral blood flow mapping with 3D acquisition.

Authors:  Dapeng Liu; Feng Xu; Wenbo Li; Peter C van Zijl; Doris D Lin; Qin Qin
Journal:  Magn Reson Med       Date:  2020-05-13       Impact factor: 4.668

7.  Hematocrit and oxygenation dependence of blood (1)H(2)O T(1) at 7 Tesla.

Authors:  Ksenija Grgac; Peter C M van Zijl; Qin Qin
Journal:  Magn Reson Med       Date:  2012-11-20       Impact factor: 4.668

8.  Noninvasive Measurements of Cerebral Blood Flow, Oxygen Extraction Fraction, and Oxygen Metabolic Index in Human with Inhalation of Air and Carbogen using Magnetic Resonance Imaging.

Authors:  Hongyu An; Souvik Sen; Yasheng Chen; William J Powers; Weili Lin
Journal:  Transl Stroke Res       Date:  2011-12-28       Impact factor: 6.829

9.  Quantitative theory for the longitudinal relaxation time of blood water.

Authors:  Wenbo Li; Ksenija Grgac; Alan Huang; Nirbhay Yadav; Qin Qin; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2015-08-18       Impact factor: 4.668

Review 10.  Noninvasive functional imaging of cerebral blood volume with vascular-space-occupancy (VASO) MRI.

Authors:  Hanzhang Lu; Jun Hua; Peter C M van Zijl
Journal:  NMR Biomed       Date:  2013-01-28       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.