Literature DB >> 23355392

Noninvasive functional imaging of cerebral blood volume with vascular-space-occupancy (VASO) MRI.

Hanzhang Lu1, Jun Hua, Peter C M van Zijl.   

Abstract

Functional MRI (fMRI) based on changes in cerebral blood volume (CBV) can probe directly vasodilatation and vasoconstriction during brain activation or physiologic challenges, and can provide important insights into the mechanism of blood oxygenation level-dependent (BOLD) signal changes. At present, the most widely used CBV fMRI technique in humans is called vascular-space-occupancy (VASO) MRI, and this article provides a technical review of this method. VASO MRI utilizes T1 differences between blood and tissue to distinguish between these two compartments within a voxel, and employs a blood-nulling inversion recovery sequence to yield an MR signal proportional to 1 - CBV. As such, vasodilatation will result in a VASO signal decrease and vasoconstriction will have the reverse effect. The VASO technique can be performed dynamically with a temporal resolution comparable with several other fMRI methods, such as BOLD or arterial spin labeling (ASL), and is particularly powerful when conducted in conjunction with these complementary techniques. The pulse sequence and imaging parameters of VASO can be optimized such that the signal change is predominantly of CBV origin, but careful considerations should be taken to minimize other contributions, such as those from the BOLD effect, cerebral blood flow (CBF) and cerebrospinal fluid (CSF). The sensitivity of the VASO technique is the primary disadvantage when compared with BOLD, but this technique is increasingly demonstrating its utility in neuroscientific and clinical applications.
Copyright © 2013 John Wiley & Sons, Ltd.

Entities:  

Keywords:  blood oxygenation level-dependent; breath-hold; cerebral blood volume; functional MRI; hypercapnia; vascular space occupancy; vasoconstriction; vasodilatation

Mesh:

Substances:

Year:  2013        PMID: 23355392      PMCID: PMC3659207          DOI: 10.1002/nbm.2905

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  122 in total

1.  Blood longitudinal (T1) and transverse (T2) relaxation time constants at 11.7 Tesla.

Authors:  Ai-Ling Lin; Qin Qin; Xia Zhao; Timothy Q Duong
Journal:  MAGMA       Date:  2011-11-10       Impact factor: 2.310

2.  Dynamic MR imaging of human brain oxygenation during rest and photic stimulation.

Authors:  J Frahm; H Bruhn; K D Merboldt; W Hänicke
Journal:  J Magn Reson Imaging       Date:  1992 Sep-Oct       Impact factor: 4.813

3.  Endogenous functional CBV contrast revealed by diffusion weighting.

Authors:  Todd B Harshbarger; Allen W Song
Journal:  NMR Biomed       Date:  2006-12       Impact factor: 4.044

4.  Theoretical and experimental investigation of the VASO contrast mechanism.

Authors:  Manus J Donahue; Hanzhang Lu; Craig K Jones; Richard A E Edden; James J Pekar; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2006-12       Impact factor: 4.668

5.  Evidence for the exchange of arterial spin-labeled water with tissue water in rat brain from diffusion-sensitized measurements of perfusion.

Authors:  A C Silva; D S Williams; A P Koretsky
Journal:  Magn Reson Med       Date:  1997-08       Impact factor: 4.668

6.  Perfusion imaging by un-inverted flow-sensitive alternating inversion recovery (UNFAIR).

Authors:  J A Helpern; C A Branch; M N Yongbi; N C Huang
Journal:  Magn Reson Imaging       Date:  1997       Impact factor: 2.546

Review 7.  The BOLD post-stimulus undershoot, one of the most debated issues in fMRI.

Authors:  Peter C M van Zijl; Jun Hua; Hanzhang Lu
Journal:  Neuroimage       Date:  2012-01-09       Impact factor: 6.556

8.  New insights into central roles of cerebral oxygen metabolism in the resting and stimulus-evoked brain.

Authors:  Xiao-Hong Zhu; Nanyin Zhang; Yi Zhang; Kâmil Uğurbil; Wei Chen
Journal:  J Cereb Blood Flow Metab       Date:  2008-09-10       Impact factor: 6.200

9.  Implementation of vascular-space-occupancy MRI at 7T.

Authors:  Jun Hua; Craig K Jones; Qin Qin; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2012-05-14       Impact factor: 4.668

10.  Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging.

Authors:  David A Feinberg; Steen Moeller; Stephen M Smith; Edward Auerbach; Sudhir Ramanna; Matthias Gunther; Matt F Glasser; Karla L Miller; Kamil Ugurbil; Essa Yacoub
Journal:  PLoS One       Date:  2010-12-20       Impact factor: 3.240

View more
  18 in total

1.  Fast measurement of blood T1 in the human carotid artery at 3T: Accuracy, precision, and reproducibility.

Authors:  Wenbo Li; Peiying Liu; Hanzhang Lu; John J Strouse; Peter C M van Zijl; Qin Qin
Journal:  Magn Reson Med       Date:  2016-07-20       Impact factor: 4.668

2.  Three-dimensional acquisition of cerebral blood volume and flow responses during functional stimulation in a single scan.

Authors:  Ying Cheng; Peter C M van Zijl; James J Pekar; Jun Hua
Journal:  Neuroimage       Date:  2014-08-23       Impact factor: 6.556

Review 3.  Imaging the physiological evolution of the ischemic penumbra in acute ischemic stroke.

Authors:  Richard Leigh; Linda Knutsson; Jinyuan Zhou; Peter Cm van Zijl
Journal:  J Cereb Blood Flow Metab       Date:  2017-03-27       Impact factor: 6.200

4.  Comparison of BOLD and CBV using 3D EPI and 3D GRASE for cortical layer functional MRI at 7 T.

Authors:  Alexander J S Beckett; Tetiana Dadakova; Jennifer Townsend; Laurentius Huber; Suhyung Park; David A Feinberg
Journal:  Magn Reson Med       Date:  2020-06-18       Impact factor: 4.668

Review 5.  Pulse sequences and parallel imaging for high spatiotemporal resolution MRI at ultra-high field.

Authors:  Benedikt A Poser; Kawin Setsompop
Journal:  Neuroimage       Date:  2017-04-06       Impact factor: 6.556

6.  Quantitative theory for the longitudinal relaxation time of blood water.

Authors:  Wenbo Li; Ksenija Grgac; Alan Huang; Nirbhay Yadav; Qin Qin; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2015-08-18       Impact factor: 4.668

Review 7.  MRI techniques to measure arterial and venous cerebral blood volume.

Authors:  Jun Hua; Peiying Liu; Tae Kim; Manus Donahue; Swati Rane; J Jean Chen; Qin Qin; Seong-Gi Kim
Journal:  Neuroimage       Date:  2018-02-16       Impact factor: 6.556

8.  Impaired response of cerebral oxygen metabolism to visual stimulation in Huntington's disease.

Authors:  Peter Klinkmueller; Martin Kronenbuerger; Xinyuan Miao; Jee Bang; Kia E Ultz; Adrian Paez; Xiaoyu Zhang; Wenzhen Duan; Russell L Margolis; Peter Cm van Zijl; Christopher A Ross; Jun Hua
Journal:  J Cereb Blood Flow Metab       Date:  2020-08-17       Impact factor: 6.200

9.  Magnetic Resonance Imaging in Aneurysmal Subarachnoid Hemorrhage: Current Evidence and Future Directions.

Authors:  Sarah E Nelson; Haris I Sair; Robert D Stevens
Journal:  Neurocrit Care       Date:  2018-10       Impact factor: 3.210

10.  Impaired cerebral vascular and metabolic responses to parametric N-back tasks in subjective cognitive decline.

Authors:  Yaoyu Zhang; Wenying Du; Yayan Yin; Huanjie Li; Zhaowei Liu; Yang Yang; Ying Han; Jia-Hong Gao
Journal:  J Cereb Blood Flow Metab       Date:  2021-05-05       Impact factor: 6.200

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.