Literature DB >> 23169066

Hematocrit and oxygenation dependence of blood (1)H(2)O T(1) at 7 Tesla.

Ksenija Grgac1, Peter C M van Zijl, Qin Qin.   

Abstract

Knowledge of blood (1)H2O T1 is critical for perfusion-based quantification experiments such as arterial spin labeling and cerebral blood volume-weighted MRI using vascular space occupancy. The dependence of blood (1)H2O T1 on hematocrit fraction (Hct) and oxygen saturation fraction (Y) was determined at 7 T using in vitro bovine blood in a circulating system under physiological conditions. Blood (1)H2O R1 values for different conditions could be readily fitted using a two-compartment (erythrocyte and plasma) model, which are described by a monoexponential longitudinal relaxation rate constant dependence. It was found that T1 = 2171 ± 39 ms for Y = 1 (arterial blood) and 2010 ± 41 ms for Y = 0.6 (venous blood), for a typical Hct of 0.42. The blood (1)H2O T1 values in the normal physiological range (Hct from 0.35 to 0.45, and Y from 0.6 to 1.0) were determined to range from 1900 to 2300 ms. The influence of oxygen partial pressure (pO2) and the effect of plasma osmolality for different anticoagulants were also investigated. It is discussed why blood (1)H2O T1 values measured in vivo for human blood may be about 10-20% larger than found in vitro for bovine blood at the same field strength.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Keywords:  7 T; hematocrit; in vitro blood; longitudinal relaxation; mean corpuscular hemoglobin concentration; oxygen partial pressure; oxygen saturation fraction; plasma osmolality

Mesh:

Substances:

Year:  2012        PMID: 23169066      PMCID: PMC3580119          DOI: 10.1002/mrm.24547

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  32 in total

1.  Imaging brain function in humans at 7 Tesla.

Authors:  E Yacoub; A Shmuel; J Pfeuffer; P F Van De Moortele; G Adriany; P Andersen; J T Vaughan; H Merkle; K Ugurbil; X Hu
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

2.  Blood longitudinal (T1) and transverse (T2) relaxation time constants at 11.7 Tesla.

Authors:  Ai-Ling Lin; Qin Qin; Xia Zhao; Timothy Q Duong
Journal:  MAGMA       Date:  2011-11-10       Impact factor: 2.310

3.  Functional magnetic resonance imaging based on changes in vascular space occupancy.

Authors:  Hanzhang Lu; Xavier Golay; James J Pekar; Peter C M Van Zijl
Journal:  Magn Reson Med       Date:  2003-08       Impact factor: 4.668

4.  Human whole-blood relaxometry at 1.5 T: Assessment of diffusion and exchange models.

Authors:  Bojana Stefanovic; G Bruce Pike
Journal:  Magn Reson Med       Date:  2004-10       Impact factor: 4.668

5.  Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla.

Authors:  Hanzhang Lu; Chekesha Clingman; Xavier Golay; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2004-09       Impact factor: 4.668

6.  Magnetic resonance imaging of stationary blood: a review.

Authors:  R A Brooks; G Di Chiro
Journal:  Med Phys       Date:  1987 Nov-Dec       Impact factor: 4.071

7.  Methemoglobin formation and reduction in man and various animal species.

Authors:  J E Smith; E Beutler
Journal:  Am J Physiol       Date:  1966-02

8.  NMR relaxation times of blood: dependence on field strength, oxidation state, and cell integrity.

Authors:  J M Gomori; R I Grossman; C Yu-Ip; T Asakura
Journal:  J Comput Assist Tomogr       Date:  1987 Jul-Aug       Impact factor: 1.826

9.  Variation of the relaxographic "shutter-speed" for transcytolemmal water exchange affects the CR bolus-tracking curve shape.

Authors:  Thomas E Yankeelov; William D Rooney; Xin Li; Charles S Springer
Journal:  Magn Reson Med       Date:  2003-12       Impact factor: 4.668

10.  Permeability studies on red cell membranes of dog, cat, and beef.

Authors:  G T Rich; R I Sha'afi; T C Barton; A K Solomon
Journal:  J Gen Physiol       Date:  1967-11       Impact factor: 4.086

View more
  24 in total

1.  A general model to calculate the spin-lattice (T1) relaxation time of blood, accounting for haematocrit, oxygen saturation and magnetic field strength.

Authors:  Patrick W Hales; Fenella J Kirkham; Christopher A Clark
Journal:  J Cereb Blood Flow Metab       Date:  2015-09-30       Impact factor: 6.200

2.  Fast measurement of blood T1 in the human carotid artery at 3T: Accuracy, precision, and reproducibility.

Authors:  Wenbo Li; Peiying Liu; Hanzhang Lu; John J Strouse; Peter C M van Zijl; Qin Qin
Journal:  Magn Reson Med       Date:  2016-07-20       Impact factor: 4.668

3.  Quantitative theory for the transverse relaxation time of blood water.

Authors:  Wenbo Li; Peter C M van Zijl
Journal:  NMR Biomed       Date:  2020-02-05       Impact factor: 4.044

4.  Relaxation properties of human umbilical cord blood at 1.5 Tesla.

Authors:  Sharon Portnoy; Mark Osmond; Meng Yuan Zhu; Mike Seed; John G Sled; Christopher K Macgowan
Journal:  Magn Reson Med       Date:  2016-04-05       Impact factor: 4.668

5.  Susceptibility-based analysis of dynamic gadolinium bolus perfusion MRI.

Authors:  David Bonekamp; Peter B Barker; Richard Leigh; Peter C M van Zijl; Xu Li
Journal:  Magn Reson Med       Date:  2014-02-25       Impact factor: 4.668

6.  Whole-brain three-dimensional T2-weighted BOLD functional magnetic resonance imaging at 7 Tesla.

Authors:  Jun Hua; Qin Qin; Peter C M van Zijl; James J Pekar; Craig K Jones
Journal:  Magn Reson Med       Date:  2013-12-12       Impact factor: 4.668

7.  Quantitative measurement of cerebral blood volume using velocity-selective pulse trains.

Authors:  Dexiang Liu; Feng Xu; Doris D Lin; Peter C M van Zijl; Qin Qin
Journal:  Magn Reson Med       Date:  2016-10-31       Impact factor: 4.668

8.  Measurement of parenchymal extravascular R2* and tissue oxygen extraction fraction using multi-echo vascular space occupancy MRI at 7 T.

Authors:  Ying Cheng; Peter C M van Zijl; Jun Hua
Journal:  NMR Biomed       Date:  2014-12-17       Impact factor: 4.044

9.  Reduced fetal cerebral oxygen consumption is associated with smaller brain size in fetuses with congenital heart disease.

Authors:  Liqun Sun; Christopher K Macgowan; John G Sled; Shi-Joon Yoo; Cedric Manlhiot; Prashob Porayette; Lars Grosse-Wortmann; Edgar Jaeggi; Brian W McCrindle; John Kingdom; Edward Hickey; Steven Miller; Mike Seed
Journal:  Circulation       Date:  2015-03-11       Impact factor: 29.690

10.  Quantitative theory for the longitudinal relaxation time of blood water.

Authors:  Wenbo Li; Ksenija Grgac; Alan Huang; Nirbhay Yadav; Qin Qin; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2015-08-18       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.