Literature DB >> 27797101

Quantitative measurement of cerebral blood volume using velocity-selective pulse trains.

Dexiang Liu1,2, Feng Xu2,3, Doris D Lin2, Peter C M van Zijl2,3, Qin Qin2,3.   

Abstract

PURPOSE: To develop a non-contrast-enhanced MRI method for cerebral blood volume (CBV) mapping using velocity-selective (VS) pulse trains.
METHODS: The new pulse sequence applied velocity-sensitive gradient waveforms in the VS label modules and velocity-compensated ones in the control scans. Sensitivities to the gradient imperfections (e.g., eddy currents) were evaluated through phantom studies. CBV quantification procedures based on simulated labeling efficiencies for arteriolar, capillary, and venular blood as a function of cutoff velocity (Vc) are presented. Experiments were conducted on healthy volunteers at 3T to examine the effects of unbalanced diffusion weighting, cerebrospinal (CSF) contamination and variation of Vc.
RESULTS: Phantom results of the used VS pulse trains demonstrated robustness to eddy currents. The mean CBV values of gray matter and white matter for the experiments using Vc = 3.5 mm/s and velocity-compensated control with CSF-nulling were 5.1 ± 0.6 mL/100 g and 2.4 ± 0.2 mL/100 g, respectively, which were 23% and 32% lower than results from the experiment with velocity-insensitive control, corresponding to 29% and 25% lower in averaged temporal signal-to-noise ratio values.
CONCLUSION: A novel technique using VS pulse trains was demonstrated for CBV mapping. The results were both qualitatively and quantitatively close to those from existing methods. Magn Reson Med 77:92-101, 2017.
© 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  arterial spin labeling; cerebral blood volume; eddy current; velocity-selective pulse train

Mesh:

Year:  2016        PMID: 27797101      PMCID: PMC5191941          DOI: 10.1002/mrm.26515

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  75 in total

1.  Fast measurement of blood T1 in the human carotid artery at 3T: Accuracy, precision, and reproducibility.

Authors:  Wenbo Li; Peiying Liu; Hanzhang Lu; John J Strouse; Peter C M van Zijl; Qin Qin
Journal:  Magn Reson Med       Date:  2016-07-20       Impact factor: 4.668

2.  An optimized velocity selective arterial spin labeling module with reduced eddy current sensitivity for improved perfusion quantification.

Authors:  James A Meakin; Peter Jezzard
Journal:  Magn Reson Med       Date:  2012-05-03       Impact factor: 4.668

3.  Modelling vascular reactivity to investigate the basis of the relationship between cerebral blood volume and flow under CO2 manipulation.

Authors:  Stefan K Piechnik; Peter A Chiarelli; Peter Jezzard
Journal:  Neuroimage       Date:  2007-08-25       Impact factor: 6.556

4.  High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis.

Authors:  L Ostergaard; R M Weisskoff; D A Chesler; C Gyldensted; B R Rosen
Journal:  Magn Reson Med       Date:  1996-11       Impact factor: 4.668

5.  Magnetic resonance imaging of perfusion.

Authors:  D Le Bihan
Journal:  Magn Reson Med       Date:  1990-05       Impact factor: 4.668

6.  An optimized design to reduce eddy current sensitivity in velocity-selective arterial spin labeling using symmetric BIR-8 pulses.

Authors:  Jia Guo; James A Meakin; Peter Jezzard; Eric C Wong
Journal:  Magn Reson Med       Date:  2014-04-07       Impact factor: 4.668

7.  Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.

Authors:  D Le Bihan; E Breton; D Lallemand; M L Aubin; J Vignaud; M Laval-Jeantet
Journal:  Radiology       Date:  1988-08       Impact factor: 11.105

8.  Bolus delay and dispersion in perfusion MRI: implications for tissue predictor models in stroke.

Authors:  Fernando Calamante; Lisa Willats; David G Gadian; Alan Connelly
Journal:  Magn Reson Med       Date:  2006-05       Impact factor: 4.668

9.  Variability of cerebral blood volume and oxygen extraction: stages of cerebral haemodynamic impairment revisited.

Authors:  Colin P Derdeyn; Tom O Videen; Kent D Yundt; Susanne M Fritsch; David A Carpenter; Robert L Grubb; William J Powers
Journal:  Brain       Date:  2002-03       Impact factor: 13.501

10.  Cerebral oxygen extraction fraction and cerebral venous blood volume measurements using MRI: effects of magnetic field variation.

Authors:  Hongyu An; Weili Lin
Journal:  Magn Reson Med       Date:  2002-05       Impact factor: 4.668

View more
  12 in total

1.  Cerebral blood volume mapping using Fourier-transform-based velocity-selective saturation pulse trains.

Authors:  Qin Qin; Yaoming Qu; Wenbo Li; Dapeng Liu; Taehoon Shin; Yansong Zhao; Doris D Lin; Peter C M van Zijl; Zhibo Wen
Journal:  Magn Reson Med       Date:  2019-02-08       Impact factor: 4.668

Review 2.  MRI techniques to measure arterial and venous cerebral blood volume.

Authors:  Jun Hua; Peiying Liu; Tae Kim; Manus Donahue; Swati Rane; J Jean Chen; Qin Qin; Seong-Gi Kim
Journal:  Neuroimage       Date:  2018-02-16       Impact factor: 6.556

3.  Three-dimensional whole-brain mapping of cerebral blood volume and venous cerebral blood volume using Fourier transform-based velocity-selective pulse trains.

Authors:  Wenbo Li; Dapeng Liu; Peter C M van Zijl; Qin Qin
Journal:  Magn Reson Med       Date:  2021-05-06       Impact factor: 4.668

4.  Ensuring both velocity and spatial responses robust to B 0 / B 1 + field inhomogeneities for velocity-selective arterial spin labeling through dynamic phase-cycling.

Authors:  Dapeng Liu; Wenbo Li; Feng Xu; Dan Zhu; Taehoon Shin; Qin Qin
Journal:  Magn Reson Med       Date:  2020-12-08       Impact factor: 4.668

5.  Perfusion measurement in brain gliomas using velocity-selective arterial spin labeling: comparison with pseudo-continuous arterial spin labeling and dynamic susceptibility contrast MRI.

Authors:  Yaoming Qu; Dexia Kong; Haitao Wen; Xiaochan Ou; Qihong Rui; Xianlong Wang; Doris D Lin; Qin Qin; Zhibo Wen
Journal:  Eur Radiol       Date:  2022-01-23       Impact factor: 5.315

6.  Spatial dependency and the role of local susceptibility for velocity selective arterial spin labeling (VS-ASL) relative tagging efficiency using accelerated 3D radial sampling with a BIR-8 preparation.

Authors:  James H Holmes; Mu-Lan Jen; Laura B Eisenmenger; Tilman Schubert; Patrick A Turski; Kevin M Johnson
Journal:  Magn Reson Med       Date:  2021-02-21       Impact factor: 3.737

7.  Robust estimation of quantitative perfusion from multi-phase pseudo-continuous arterial spin labeling.

Authors:  Y Msayib; M Craig; M A Simard; J R Larkin; D D Shin; T T Liu; N R Sibson; T W Okell; M A Chappell
Journal:  Magn Reson Med       Date:  2019-08-20       Impact factor: 4.668

8.  Venous contribution to sodium MRI in the human brain.

Authors:  Ian D Driver; Robert W Stobbe; Richard G Wise; Christian Beaulieu
Journal:  Magn Reson Med       Date:  2019-09-25       Impact factor: 4.668

9.  Magnetic resonance angiography and perfusion mapping by arterial spin labeling using Fourier transform-based velocity-selective pulse trains: Examination on a commercial perfusion phantom.

Authors:  Feng Xu; Dan Zhu; Hongli Fan; Hanzhang Lu; Dapeng Liu; Wenbo Li; Qin Qin
Journal:  Magn Reson Med       Date:  2021-05-02       Impact factor: 4.668

10.  T2-Weighted Whole-Brain Intracranial Vessel Wall Imaging at 3 Tesla With Cerebrospinal Fluid Suppression.

Authors:  Lei Zhang; Yanjie Zhu; Yulong Qi; Liwen Wan; Lijie Ren; Yi Zhu; Na Zhang; Dong Liang; Ye Li; Hairong Zheng; Xin Liu
Journal:  Front Neurosci       Date:  2021-06-25       Impact factor: 4.677

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.