Reliability and reproducibility of linear mandible measurements with the use of a cone-beam computed tomography and two object inclinations.

C Tomasi1, E Bressan, B Corazza, S Mazzoleni, E Stellini, A Lith.   

Abstract

OBJECTIVE: The aim of this study was to assess the influence of inclination of the object on the reliability and reproducibility of linear measurements of anatomic structures of the mandible on images obtained using cone-beam CT (CBCT).
METHODS: Ten linear dimensions between anatomical landmarks were measured in a dry mandible. The measurements were performed with a manual calliper three times by three observers. The mandible was scanned with Planmeca Promax 3D cone-beam CT (Planmeca Oy, Helsinki, Finland) with the base of the mandible parallel as well as tilted 45° to the horizontal plane. Computer measurements of the linear dimension were performed by three observers. The radiographic measurements were performed four times for each experimental setting. A total of 240 measurements were performed. Reproducibility was evaluated through comparison of standard deviation (SD) and estimation of intraclass correlation coefficient (ICC). The error was estimated as the absolute difference between the radiographic measurements and the mean manual calliper measurements.
RESULTS: The mean SD for the radiographic measurements was 0.36 mm for the horizontally positioned mandible and 0.48 mm for the inclined mandible. The ICC between examiners was 0.996 mm, between sessions was 0.990 mm and between CBCT measurements and calliper was 0.992 mm. The overall absolute mean measurement error was 0.40 mm (SD 0.39 mm). The percentage of errors that exceeded 1 mm was 6.7%.
CONCLUSION: The results revealed high reliability of measurements performed on CBCT images independently from object position, examiner's experience and high reproducibility in repeated measurements settings.

Mesh:

Year:  2011        PMID: 21493881      PMCID: PMC3520315          DOI: 10.1259/dmfr/17432330

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  29 in total

1.  Effect of mandibular positioning on preimplant site measurement of the mandible in reformatted CT.

Authors:  Kee-Deog Kim; Ho-Gul Jeong; Seong-Ho Choi; Eui-Hwan Hwang; Chang-Seo Park
Journal:  Int J Periodontics Restorative Dent       Date:  2003-04       Impact factor: 1.840

2.  Clinical indications for digital volume tomography in oral and maxillofacial surgery.

Authors:  C M Ziegler; R Woertche; J Brief; S Hassfeld
Journal:  Dentomaxillofac Radiol       Date:  2002-03       Impact factor: 2.419

3.  Implant imaging for the dentist.

Authors:  Muralidhar Mupparapu; Steven R Singer
Journal:  J Can Dent Assoc       Date:  2004-01       Impact factor: 1.316

4.  Study on the necessity for cross-section imaging of the posterior mandible for treatment planning of standard cases in implant dentistry.

Authors:  Christian Frei; Daniel Buser; Karl Dula
Journal:  Clin Oral Implants Res       Date:  2004-08       Impact factor: 5.977

5.  Measurement of mandibles with microfocus x-ray computerized tomography and compact computerized tomography for dental use.

Authors:  Munetaka Naitoh; Akitoshi Katsumata; Shogo Mitsuya; Hiromasa Kamemoto; Eiichiro Ariji
Journal:  Int J Oral Maxillofac Implants       Date:  2004 Mar-Apr       Impact factor: 2.804

6.  Accuracy in measurement of distance using limited cone-beam computerized tomography.

Authors:  Kaoru Kobayashi; Shinji Shimoda; Yoichi Nakagawa; Akira Yamamoto
Journal:  Int J Oral Maxillofac Implants       Date:  2004 Mar-Apr       Impact factor: 2.804

7.  Experimental flat-panel high-spatial-resolution volume CT of the temporal bone.

Authors:  Rajiv Gupta; Soenke H Bartling; Samit K Basu; William R Ross; Hartmut Becker; Armin Pfoh; Thomas Brady; Hugh D Curtin
Journal:  AJNR Am J Neuroradiol       Date:  2004-09       Impact factor: 3.825

8.  Accuracy and precision of linear measurements in cone beam computed tomography Accuitomo tomograms obtained with different reconstruction techniques.

Authors:  H Lund; K Gröndahl; H-G Gröndahl
Journal:  Dentomaxillofac Radiol       Date:  2009-09       Impact factor: 2.419

9.  Measurement error and correlation coefficients.

Authors:  J M Bland; D G Altman
Journal:  BMJ       Date:  1996-07-06

10.  Three-dimensional localization of maxillary canines with cone-beam computed tomography.

Authors:  Leah Walker; Reyes Enciso; James Mah
Journal:  Am J Orthod Dentofacial Orthop       Date:  2005-10       Impact factor: 2.650

View more
  18 in total

1.  Accuracy of 3D cephalometric measurements based on an automatic knowledge-based landmark detection algorithm.

Authors:  Abhishek Gupta; Om Prakash Kharbanda; Viren Sardana; Rajiv Balachandran; Harish Kumar Sardana
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-12-24       Impact factor: 2.924

2.  Classification of periodontal biotypes with the use of CBCT. A cross-sectional study.

Authors:  Maria Nikiforidou; Lazaros Tsalikis; Christos Angelopoulos; Georgios Menexes; Ioannis Vouros; Antonios Konstantinides
Journal:  Clin Oral Investig       Date:  2015-12-22       Impact factor: 3.573

3.  The use of cone beam computed tomography to predetermine root canal lengths in molar teeth: a comparison between two-dimensional and three-dimensional measurements.

Authors:  J P Tchorz; P J Poxleitner; S Stampf; S B M Patzelt; D Rottke; E Hellwig; M J Altenburger
Journal:  Clin Oral Investig       Date:  2013-07-30       Impact factor: 3.573

4.  The effect of scan parameters on cone beam CT trabecular bone microstructural measurements of the human mandible.

Authors:  N Ibrahim; A Parsa; B Hassan; P van der Stelt; I H A Aartman; D Wismeijer
Journal:  Dentomaxillofac Radiol       Date:  2013-10-16       Impact factor: 2.419

5.  Accuracy of linear measurement using cone-beam computed tomography at different reconstruction angles.

Authors:  Sima Nikneshan; Shadi Hamidi Aval; Neema Bakhshalian; Shahriyar Shahab; Mahdis Mohammadpour; Soodeh Sarikhani
Journal:  Imaging Sci Dent       Date:  2014-11-25

6.  Reproducibility of CBCT image analysis: a clinical study on intrapersonal and interpersonal errors in bone structure determination.

Authors:  Sigmar Schnutenhaus; Michael Graf; Isabel Doering; Ralph G Luthardt; Heike Rudolph
Journal:  Oral Radiol       Date:  2018-07-27       Impact factor: 1.852

7.  Accuracy of peri-implant bone thickness and validity of assessing bone augmentation material using cone beam computed tomography.

Authors:  Dongyun Wang; Andreas Künzel; Vladimir Golubovic; Ilya Mihatovic; Gordon John; Zhuofan Chen; Jürgen Becker; Frank Schwarz
Journal:  Clin Oral Investig       Date:  2012-10-12       Impact factor: 3.573

8.  Three-dimensional localization of impacted canines and root resorption assessment using cone beam computed tomography.

Authors:  Eyad Almuhtaseb; Jing Mao; Derek Mahony; Rawan Bader; Zhi-Xing Zhang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2014-06-18

9.  Donor age-related biological properties of human dental pulp stem cells change in nanostructured scaffolds.

Authors:  Eriberto Bressan; Letizia Ferroni; Chiara Gardin; Paolo Pinton; Edoardo Stellini; Daniele Botticelli; Stefano Sivolella; Barbara Zavan
Journal:  PLoS One       Date:  2012-11-28       Impact factor: 3.240

Review 10.  Nanostructured surfaces of dental implants.

Authors:  Eriberto Bressan; Luca Sbricoli; Riccardo Guazzo; Ilaria Tocco; Marco Roman; Vincenzo Vindigni; Edoardo Stellini; Chiara Gardin; Letizia Ferroni; Stefano Sivolella; Barbara Zavan
Journal:  Int J Mol Sci       Date:  2013-01-17       Impact factor: 5.923

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.