The impact of anthropometric patient-phantom matching on organ dose: a hybrid phantom study for fluoroscopy guided interventions.

Perry B Johnson1, Amy Geyer, David Borrego, Kayla Ficarrotta, Kevin Johnson, Wesley E Bolch.   

Abstract

PURPOSE: To investigate the benefits and limitations of patient-phantom matching for determining organ dose during fluoroscopy guided interventions.
METHODS: In this study, 27 CT datasets representing patients of different sizes and genders were contoured and converted into patient-specific computational models. Each model was matched, based on height and weight, to computational phantoms selected from the UF hybrid patient-dependent series. In order to investigate the influence of phantom type on patient organ dose, Monte Carlo methods were used to simulate two cardiac projections (PA/left lateral) and two abdominal projections (RAO/LPO). Organ dose conversion coefficients were then calculated for each patient-specific and patient-dependent phantom and also for a reference stylized and reference hybrid phantom. The coefficients were subsequently analyzed for any correlation between patient-specificity and the accuracy of the dose estimate. Accuracy was quantified by calculating an absolute percent difference using the patient-specific dose conversion coefficients as the reference.
RESULTS: Patient-phantom matching was shown most beneficial for estimating the dose to heavy patients. In these cases, the improvement over using a reference stylized phantom ranged from approximately 50% to 120% for abdominal projections and for a reference hybrid phantom from 20% to 60% for all projections. For lighter individuals, patient-phantom matching was clearly superior to using a reference stylized phantom, but not significantly better than using a reference hybrid phantom for certain fields and projections.
CONCLUSIONS: The results indicate two sources of error when patients are matched with phantoms: Anatomical error, which is inherent due to differences in organ size and location, and error attributed to differences in the total soft tissue attenuation. For small patients, differences in soft tissue attenuation are minimal and are exceeded by inherent anatomical differences. For large patients, difference in soft tissue attenuation can be large. In these cases, patient-phantom matching proves most effective as differences in soft tissue attenuation are mitigated. With increasing obesity rates, overweight patients will continue to make up a growing fraction of all patients undergoing medical imaging. Thus, having phantoms that better represent this population represents a considerable improvement over previous methods. In response to this study, additional phantoms representing heavier weight percentiles will be added to the UFHADM and UFHADF patient-dependent series.

Entities:  

Mesh:

Year:  2011        PMID: 21452738      PMCID: PMC3045414          DOI: 10.1118/1.3544353

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Organ dose conversion coefficients for external photon irradiation of male and female voxel models.

Authors:  M Zanki; U Fill; N Petoussi-Henss; D Regulla
Journal:  Phys Med Biol       Date:  2002-07-21       Impact factor: 3.609

2.  Revisions to the ORNL series of adult and pediatric computational phantoms for use with the MIRD schema.

Authors:  Eun Young Han; Wesley E Bolch; Keith F Eckerman
Journal:  Health Phys       Date:  2006-04       Impact factor: 1.316

3.  The influence of patient size on dose conversion coefficients: a hybrid phantom study for adult cardiac catheterization.

Authors:  Perry Johnson; Choonsik Lee; Kevin Johnson; Daniel Siragusa; Wesley E Bolch
Journal:  Phys Med Biol       Date:  2009-05-21       Impact factor: 3.609

4.  Deformable adult human phantoms for radiation protection dosimetry: anthropometric data representing size distributions of adult worker populations and software algorithms.

Authors:  Yong Hum Na; Binquan Zhang; Juying Zhang; Peter F Caracappa; X George Xu
Journal:  Phys Med Biol       Date:  2010-06-15       Impact factor: 3.609

5.  FASH and MASH: female and male adult human phantoms based on polygon mesh surfaces: I. Development of the anatomy.

Authors:  V F Cassola; V J de Melo Lima; R Kramer; H J Khoury
Journal:  Phys Med Biol       Date:  2010-01-07       Impact factor: 3.609

6.  The UF family of reference hybrid phantoms for computational radiation dosimetry.

Authors:  Choonsik Lee; Daniel Lodwick; Jorge Hurtado; Deanna Pafundi; Jonathan L Williams; Wesley E Bolch
Journal:  Phys Med Biol       Date:  2009-12-17       Impact factor: 3.609

7.  RPI-AM and RPI-AF, a pair of mesh-based, size-adjustable adult male and female computational phantoms using ICRP-89 parameters and their calculations for organ doses from monoenergetic photon beams.

Authors:  Juying Zhang; Yong Hum Na; Peter F Caracappa; X George Xu
Journal:  Phys Med Biol       Date:  2009-09-17       Impact factor: 3.609

  7 in total
  5 in total

1.  Skin dose mapping for fluoroscopically guided interventions.

Authors:  Perry B Johnson; David Borrego; Stephen Balter; Kevin Johnson; Daniel Siragusa; Wesley E Bolch
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  Assessment of PCXMC for patients with different body size in chest and abdominal x ray examinations: a Monte Carlo simulation study.

Authors:  David Borrego; Erin M Lowe; Cari M Kitahara; Choonsik Lee
Journal:  Phys Med Biol       Date:  2018-03-21       Impact factor: 3.609

3.  Image Quality and Dose Comparison of 3 Mobile Intraoperative Three-Dimensional Imaging Systems in Spine Surgery.

Authors:  Norah Foster; Christopher Shaffrey; Avery Buchholz; Raymond Turner; Lexie Zidanyue Yang; Donna Niedzwiecki; Allen Goode
Journal:  World Neurosurg       Date:  2022-01-01       Impact factor: 2.210

4.  Individualized adjustments to reference phantom internal organ dosimetry-scaling factors given knowledge of patient internal anatomy.

Authors:  Michael B Wayson; Wesley E Bolch
Journal:  Phys Med Biol       Date:  2018-04-13       Impact factor: 3.609

5.  Organ doses in pediatric patients undergoing cardiac-centered fluoroscopically guided interventions: Comparison of three methods for computational phantom alignment.

Authors:  Emily L Marshall; David Borrego; James C Fudge; Dhanashree Rajderkar; Wesley E Bolch
Journal:  Med Phys       Date:  2018-06-13       Impact factor: 4.071

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.