Fast, 3D radio-frequency transmit field (B1) mapping is important for parallel transmission, spatially selective pulse design and quantitative MRI applications. It has been shown that actual flip angle imaging--two interleaved spoiled gradient recalled echo images acquired in steady state with two very short time delays (TR1, TR2)--is an attractive method of B1 mapping. Herein, we describe the TROMBONE method that efficiently integrates actual flip angle imaging with EPI imaging, alleviates very short TR requirement of actual flip angle imaging and through their synergy yields up to 16 times higher precision in B1 estimation in the same experimental time. High precision of TROMBONE can be traded for faster scans. The map of B1 reconstructed from the ratio of intensities of two images is insensitive to longitudinal relaxation time (T1) in the physiologically relevant range. A table of the optimal acquisition protocol parameters for various target experimental conditions is provided.
Copyright © 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21394765      PMCID: PMC3130840          DOI: 10.1002/mrm.22804

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  28 in total

1.  Parallel excitation with an array of transmit coils.

Authors:  Yudong Zhu
Journal:  Magn Reson Med       Date:  2004-04       Impact factor: 4.668

2.  A k-space analysis of small-tip-angle excitation. 1989.

Authors:  John Pauly; Dwight Nishimura; Albert Macovski
Journal:  J Magn Reson       Date:  2011-12       Impact factor: 2.229

3.  T1 corrected B1 mapping using multi-TR gradient echo sequences.

Authors:  Tobias Voigt; Kay Nehrke; Olaf Doessel; Ulrich Katscher
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

4.  Measurement and correction of transmitter and receiver induced nonuniformities in vivo.

Authors:  Jinghua Wang; Maolin Qiu; Qing X Yang; Michael B Smith; R Todd Constable
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

5.  Actual flip-angle imaging in the pulsed steady state: a method for rapid three-dimensional mapping of the transmitted radiofrequency field.

Authors:  Vasily L Yarnykh
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

6.  Optimized and combined T1 and B1 mapping technique for fast and accurate T1 quantification in contrast-enhanced abdominal MRI.

Authors:  Reto Treier; Andreas Steingoetter; Michael Fried; Werner Schwizer; Peter Boesiger
Journal:  Magn Reson Med       Date:  2007-03       Impact factor: 4.668

7.  TriTone: a radiofrequency field (B1)-insensitive T1 estimator for MRI at high magnetic fields.

Authors:  Roman Fleysher; Lazar Fleysher; Songtao Liu; Oded Gonen
Journal:  Magn Reson Imaging       Date:  2008-05-22       Impact factor: 2.546

8.  Imaging of the active B1 field in vivo.

Authors:  R Stollberger; P Wach
Journal:  Magn Reson Med       Date:  1996-02       Impact factor: 4.668

9.  Curved slice imaging.

Authors:  P Börnert; T Schäffter
Journal:  Magn Reson Med       Date:  1996-12       Impact factor: 4.668

Review 10.  Assessment of renal function with dynamic contrast-enhanced MR imaging.

Authors:  Louisa Bokacheva; Henry Rusinek; Jeff L Zhang; Vivian S Lee
Journal:  Magn Reson Imaging Clin N Am       Date:  2008-11       Impact factor: 2.266

View more
  2 in total

1.  TROMBONE: T1-relaxation-oblivious mapping of transmit radio-frequency field (B1) for MRI at high magnetic fields.

Authors:  Roman Fleysher; Lazar Fleysher; Matilde Inglese; Daniel Sodickson
Journal:  Magn Reson Med       Date:  2011-03-09       Impact factor: 4.668

2.  Use of a radio frequency shield during 1.5 and 3.0 Tesla magnetic resonance imaging: experimental evaluation.

Authors:  Christopher P Favazza; Deirdre M King; Heidi A Edmonson; Joel P Felmlee; Phillip J Rossman; Nicholas J Hangiandreou; Robert E Watson; Krzysztof R Gorny
Journal:  Med Devices (Auckl)       Date:  2014-10-29
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.