Literature DB >> 15678526

Measurement and correction of transmitter and receiver induced nonuniformities in vivo.

Jinghua Wang1, Maolin Qiu, Qing X Yang, Michael B Smith, R Todd Constable.   

Abstract

Signal intensity nonuniformities in high field MR imaging limit the ability of MRI to provide quantitative information and can negatively impact diagnostic scan quality. In this paper, a simple method is described for correcting these effects based on in vivo measurement of the transmission field B1+ and reception sensitivity maps. These maps can be obtained in vivo with either gradient echo (GE) or spin echo (SE) imaging sequences, but the SE approach exhibits an advantage over the GE approach for correcting images over a range of flip angles. In a uniform phantom, this approach reduced the ratio of the signal SD to its mean from around 30% before correction to approximately 6% for the SE approach and 9% for the GE approach after correction. The application of the SE approach for correcting intensity nonuniformities is demonstrated in vivo with human brain images obtained using a conventional spin echo sequence at 3.0 T. Furthermore, it is also shown that this in vivo B1+ and reception sensitivity mapping can be performed using segmented echo planar imaging sequences providing acquisition times of less than 2 min. Although the correction presented here is demonstrated with a simultaneous transmit and receive volume coil, it can be extended to the case of separate transmission and reception coils, including surface and phase array coils.

Entities:  

Mesh:

Year:  2005        PMID: 15678526     DOI: 10.1002/mrm.20354

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  26 in total

1.  Quantitative MR imaging of two-pool magnetization transfer model parameters in myelin mutant shaking pup.

Authors:  Alexey Samsonov; Andrew L Alexander; Pouria Mossahebi; Yu-Chien Wu; Ian D Duncan; Aaron S Field
Journal:  Neuroimage       Date:  2012-06-01       Impact factor: 6.556

Review 2.  Proton MR spectroscopy of the brain at 3 T: an update.

Authors:  Alfonso Di Costanzo; Francesca Trojsi; Michela Tosetti; Timo Schirmer; Silke M Lechner; Teresa Popolizio; Tommaso Scarabino
Journal:  Eur Radiol       Date:  2007-01-18       Impact factor: 5.315

3.  Reduction of transmitter B1 inhomogeneity with transmit SENSE slice-select pulses.

Authors:  Zhenghui Zhang; Chun-Yu Yip; William Grissom; Douglas C Noll; Fernando E Boada; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2007-05       Impact factor: 4.668

4.  Fast-kz three-dimensional tailored radiofrequency pulse for reduced B1 inhomogeneity.

Authors:  Suwit Saekho; Chun-yu Yip; Douglas C Noll; Fernando E Boada; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2006-04       Impact factor: 4.668

5.  Comparison of three commercially available radio frequency coils for human brain imaging at 3 Tesla.

Authors:  Ralf Mekle; Wietske van der Zwaag; Andreas Joosten; Rolf Gruetter
Journal:  MAGMA       Date:  2008-01-10       Impact factor: 2.310

6.  Restoration of MRI data for intensity non-uniformities using local high order intensity statistics.

Authors:  Stathis Hadjidemetriou; Colin Studholme; Susanne Mueller; Michael Weiner; Norbert Schuff
Journal:  Med Image Anal       Date:  2008-06-07       Impact factor: 8.545

7.  Pushing the limits of in vivo diffusion MRI for the Human Connectome Project.

Authors:  K Setsompop; R Kimmlingen; E Eberlein; T Witzel; J Cohen-Adad; J A McNab; B Keil; M D Tisdall; P Hoecht; P Dietz; S F Cauley; V Tountcheva; V Matschl; V H Lenz; K Heberlein; A Potthast; H Thein; J Van Horn; A Toga; F Schmitt; D Lehne; B R Rosen; V Wedeen; L L Wald
Journal:  Neuroimage       Date:  2013-05-24       Impact factor: 6.556

8.  Fast slice-selective radio-frequency excitation pulses for mitigating B+1 inhomogeneity in the human brain at 7 Tesla.

Authors:  Adam C Zelinski; Lawrence L Wald; Kawin Setsompop; Vijayanand Alagappan; Borjan A Gagoski; Vivek K Goyal; Elfar Adalsteinsson
Journal:  Magn Reson Med       Date:  2008-06       Impact factor: 4.668

Review 9.  Magnetic-resonance-based electrical properties tomography: a review.

Authors:  Xiaotong Zhang; Jiaen Liu; Bin He
Journal:  IEEE Rev Biomed Eng       Date:  2014

Review 10.  Evaluation of Head and Neck Tumors with Functional MR Imaging.

Authors:  Jacobus F A Jansen; Carlos Parra; Yonggang Lu; Amita Shukla-Dave
Journal:  Magn Reson Imaging Clin N Am       Date:  2016-02       Impact factor: 2.266

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.