Literature DB >> 20564577

T1 corrected B1 mapping using multi-TR gradient echo sequences.

Tobias Voigt1, Kay Nehrke, Olaf Doessel, Ulrich Katscher.   

Abstract

This work presents a new approach toward a fast, simultaneous amplitude of radiofrequency field (B(1)) and T(1) mapping technique. The new method is based on the "actual flip angle imaging" (AFI) sequence. However, the single pulse repetition time (TR) pair used in the standard AFI sequence is replaced by multiple pulse repetition time sets. The resulting method was called "multiple TR B(1)/T(1) mapping" (MTM). In this study, MTM was investigated and compared to standard AFI in simulations and experiments. Feasibility and reliability of MTM were proven in phantom and in vivo experiments. Error propagation theory was applied to identify optimal sequence parameters and to facilitate a systematic noise comparison to standard AFI. In terms of accuracy and signal-to-noise ratio, the presented method outperforms standard AFI B(1) mapping over a wide range of T(1). Finally, the capability of MTM to determine T(1) was analyzed qualitatively and quantitatively, yielding good agreement with reference measurements. 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20564577     DOI: 10.1002/mrm.22333

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  12 in total

1.  Dynamic contrast enhanced magnetic resonance imaging of an orthotopic pancreatic cancer mouse model.

Authors:  Hyunki Kim; Sharon Samuel; John W Totenhagen; Marie Warren; Jeffrey C Sellers; Donald J Buchsbaum
Journal:  J Vis Exp       Date:  2015-04-18       Impact factor: 1.355

2.  Fast and high-resolution quantitative mapping of tissue water content with full brain coverage for clinically-driven studies.

Authors:  Mohammad Sabati; Andrew A Maudsley
Journal:  Magn Reson Imaging       Date:  2013-09-17       Impact factor: 2.546

3.  Variability in Quantitative DCE-MRI: Sources and Solutions.

Authors:  Harrison Kim
Journal:  J Nat Sci       Date:  2018

4.  Simultaneous variable flip angle-actual flip angle imaging method for improved accuracy and precision of three-dimensional T1 and B1 measurements.

Authors:  Samuel A Hurley; Vasily L Yarnykh; Kevin M Johnson; Aaron S Field; Andrew L Alexander; Alexey A Samsonov
Journal:  Magn Reson Med       Date:  2011-12-02       Impact factor: 4.668

5.  Potential clinical impact of multiparametric quantitative MR spectroscopy in neurological disorders: A review and analysis.

Authors:  Ivan I Kirov; Assaf Tal
Journal:  Magn Reson Med       Date:  2019-08-08       Impact factor: 4.668

6.  Simultaneous measurement of T1 /B1 and pharmacokinetic model parameters using active contrast encoding (ACE)-MRI.

Authors:  Jin Zhang; Kerryanne Winters; Olivier Reynaud; Sungheon Gene Kim
Journal:  NMR Biomed       Date:  2017-05-22       Impact factor: 4.044

7.  TROMBONE: T1-relaxation-oblivious mapping of transmit radio-frequency field (B1) for MRI at high magnetic fields.

Authors:  Roman Fleysher; Lazar Fleysher; Matilde Inglese; Daniel Sodickson
Journal:  Magn Reson Med       Date:  2011-03-09       Impact factor: 4.668

8.  B1 and T1 mapping of the breast with a reference tissue method.

Authors:  Federico D Pineda; Milica Medved; Xiaobing Fan; Gregory S Karczmar
Journal:  Magn Reson Med       Date:  2015-05-27       Impact factor: 4.668

9.  Myelin water fraction estimation using small-tip fast recovery MRI.

Authors:  Steven T Whitaker; Gopal Nataraj; Jon-Fredrik Nielsen; Jeffrey A Fessler
Journal:  Magn Reson Med       Date:  2020-04-12       Impact factor: 4.668

Review 10.  Quantitative imaging biomarkers alliance (QIBA) recommendations for improved precision of DWI and DCE-MRI derived biomarkers in multicenter oncology trials.

Authors:  Amita Shukla-Dave; Nancy A Obuchowski; Thomas L Chenevert; Sachin Jambawalikar; Lawrence H Schwartz; Dariya Malyarenko; Wei Huang; Susan M Noworolski; Robert J Young; Mark S Shiroishi; Harrison Kim; Catherine Coolens; Hendrik Laue; Caroline Chung; Mark Rosen; Michael Boss; Edward F Jackson
Journal:  J Magn Reson Imaging       Date:  2018-11-19       Impact factor: 5.119

View more