Characterizing the MTF in 3D for a Quantized SPECT Camera Having Arbitrary Trajectories.

Priti Madhav1, James E Bowsher, Spencer J Cutler, Martin P Tornai.   

Abstract

The emergence of application-specific 3D tomographic small animal and dedicated breast imaging systems has stimulated the development of simple methods to quantify the spatial resolution or Modulation Transfer Function (MTF) of the system in three dimensions. Locally determined MTFs, obtained from line source measurements at specific locations, can characterize spatial variations in the system resolution and can help correct for such variations. In this study, a method is described to measure the MTF in 3D for a compact SPECT system that uses a 16 × 20 cm(2) CZT-based compact gamma camera and 3D positioning gantry capable of moving in different trajectories. Image data are acquired for a novel phantom consisting of three radioactivity-filled capillary tubes, positioned nearly orthogonally to each other. These images provide simultaneous measurements of the local MTF along three dimensions of the reconstructed imaged volume. The usefulness of this approach is shown by characterizing the MTF at different locations in the reconstructed imaged 3D volume using various (1) energy windows; (2) iterative reconstruction parameters including number of iterations, voxel size, and number of projection views; (3) simple and complex 3D orbital trajectories including simple vertical axis of rotation, simple tilt, complex circle-plus-arc, and complex sinusoids projected onto a hemisphere; and (4) object shapes in the camera's field of view. Results indicate that the method using the novel phantom can provide information on spatial resolution effects caused by system design, sampling, energy windows, reconstruction parameters, novel 3D orbital trajectories, and object shapes. Based on these measurements that are useful for dedicated tomographic breast imaging, it was shown that there were small variations in the MTF in 3D for various energy windows and reconstruction parameters. However, complex trajectories that uniformly sample the breast volume of interest were quantitatively shown to have slightly better spatial resolution performance than more simple orbits.

Entities:  

Year:  2009        PMID: 21331301      PMCID: PMC3039453          DOI: 10.1109/TNS.2009.2013464

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  9 in total

1.  The effect of intrinsic attenuation correction methods on the stationarity of the 3-D modulation transfer function of SPECT.

Authors:  S J Glick; W G Hawkins; M A King; B C Penney; E J Soares; C L Byrne
Journal:  Med Phys       Date:  1992 Jul-Aug       Impact factor: 4.071

2.  FastSPECT II: A Second-Generation High-Resolution Dynamic SPECT Imager.

Authors:  Lars R Furenlid; Donald W Wilson; Yi-Chun Chen; Hyunki Kim; Philip J Pietraski; Michael J Crawford; Harrison H Barrett
Journal:  IEEE Trans Nucl Sci       Date:  2004-06       Impact factor: 1.679

3.  Performance of dedicated emission mammotomography for various breast shapes and sizes.

Authors:  C N Brzymialkiewicz; M P Tornai; R L McKinley; S J Cutler; J E Bowsher
Journal:  Phys Med Biol       Date:  2006-09-19       Impact factor: 3.609

4.  Simplified method for determining the modulation transfer function for the scintillation camera.

Authors:  M L Nusynowitz; A R Benedetto
Journal:  J Nucl Med       Date:  1975-12       Impact factor: 10.057

5.  A simple method for determining the modulation transfer function in digital radiography.

Authors:  H Fujita; D Y Tsai; T Itoh; K Doi; J Morishita; K Ueda; A Ohtsuka
Journal:  IEEE Trans Med Imaging       Date:  1992       Impact factor: 10.048

6.  A method for measuring the presampled MTF of digital radiographic systems using an edge test device.

Authors:  E Samei; M J Flynn; D A Reimann
Journal:  Med Phys       Date:  1998-01       Impact factor: 4.071

7.  Evaluation of fully 3-D emission mammotomography with a compact cadmium zinc telluride detector.

Authors:  Caryl N Brzymialkiewicz; Martin P Tornai; Randolph L McKinley; James E Bowsher
Journal:  IEEE Trans Med Imaging       Date:  2005-07       Impact factor: 10.048

8.  Methods for measuring the modulation transfer function of gamma camera systems.

Authors:  T Väyrynen; U Pitkänen; K Kiviniitty
Journal:  Eur J Nucl Med       Date:  1980

9.  Characterizing the MTF in 3D for a Quantized SPECT Camera Having Arbitrary Trajectories.

Authors:  Priti Madhav; James E Bowsher; Spencer J Cutler; Martin P Tornai
Journal:  IEEE Trans Nucl Sci       Date:  2009-06-01       Impact factor: 1.679

  9 in total
  2 in total

1.  Observer detection limits for a dedicated SPECT breast imaging system.

Authors:  S J Cutler; K L Perez; H X Barnhart; M P Tornai
Journal:  Phys Med Biol       Date:  2010-03-12       Impact factor: 3.609

2.  Characterizing the MTF in 3D for a Quantized SPECT Camera Having Arbitrary Trajectories.

Authors:  Priti Madhav; James E Bowsher; Spencer J Cutler; Martin P Tornai
Journal:  IEEE Trans Nucl Sci       Date:  2009-06-01       Impact factor: 1.679