The effect of intrinsic attenuation correction methods on the stationarity of the 3-D modulation transfer function of SPECT.

S J Glick1, W G Hawkins, M A King, B C Penney, E J Soares, C L Byrne.   

Abstract

The application of stationary restoration techniques to SPECT images assumes that the modulation transfer function (MTF) of the imaging system is shift invariant. It was hypothesized that using intrinsic attenuation correction (i.e., methods which explicitly invert the exponential radon transform) would yield a three-dimensional (3-D) MTF which varies less with position within the transverse slices than the combined conjugate view two-dimensional (2-D) MTF varies with depth. Thus the assumption of shift invariance would become less of an approximation for 3-D post- than for 2-D pre-reconstruction restoration filtering. SPECT acquisitions were obtained from point sources located at various positions in three differently shaped, water-filled phantoms. The data were reconstructed with intrinsic attenuation correction, and 3-D MTFs were calculated. Four different intrinsic attenuation correction methods were compared: (1) exponentially weighted backprojection, (2) a modified exponentially weighted backprojection as described by Tanaka et al. [Phys. Med. Biol. 29, 1489-1500 (1984)], (3) a Fourier domain technique as described by Bellini et al. [IEEE Trans. ASSP 27, 213-218 (1979)], and (4) the circular harmonic transform (CHT) method as described by Hawkins et al. [IEEE Trans. Med. Imag. 7, 135-148 (1988)]. The dependence of the 3-D MTF obtained with these methods, on point source location within an attenuator, and on shape of the attenuator, was studied. These 3-D MTFs were compared to: (1) those MTFs obtained with no attenuation correction, and (2) the depth dependence of the arithmetic mean combined conjugate view 2-D MTFs.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1992        PMID: 1518474     DOI: 10.1118/1.596773

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Correction of partial volume effects in myocardial SPECT.

Authors:  B F Hutton; A Osiecki
Journal:  J Nucl Cardiol       Date:  1998 Jul-Aug       Impact factor: 5.952

2.  A Monte Carlo investigation of artifacts caused by liver uptake in single-photon emission computed tomography perfusion imaging with technetium 99m-labeled agents.

Authors:  M A King; W Xia; D J deVries; T S Pan; B J Villegas; S Dahlberg; B M Tsui; M H Ljungberg; H T Morgan
Journal:  J Nucl Cardiol       Date:  1996 Jan-Feb       Impact factor: 5.952

3.  Characterizing the MTF in 3D for a Quantized SPECT Camera Having Arbitrary Trajectories.

Authors:  Priti Madhav; James E Bowsher; Spencer J Cutler; Martin P Tornai
Journal:  IEEE Trans Nucl Sci       Date:  2009-06-01       Impact factor: 1.679

4.  Influence of the assessment of defect severity and intravenous nitrate administration during tracer injection on the detection of viable hibernating myocardium with data-based quantitative technetium 99m-labeled sestamibi single-photon emission computed tomography.

Authors:  R Sciagrà; G Bisi; G M Santoro; M Agnolucci; O Zoccarato; P F Fazzini
Journal:  J Nucl Cardiol       Date:  1996 May-Jun       Impact factor: 5.952

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.