Literature DB >> 20224159

Observer detection limits for a dedicated SPECT breast imaging system.

S J Cutler1, K L Perez, H X Barnhart, M P Tornai.   

Abstract

An observer-based contrast-detail study is performed in an effort to evaluate the limits of object detectability using a dedicated CZT-based breast SPECT imaging system under various imaging conditions. A custom geometric contrast-resolution phantom was developed that can be used for both positive ('hot') and negative contrasts ('cold'). The 3 cm long fillable tubes are arranged in six sectors having equal inner diameters ranging from 1 mm to 6 mm with plastic wall thicknesses of <0.25 mm, on a pitch of twice their inner diameters. Scans of the activity filled tubes using simple circular trajectories are obtained in a 215 mL uniform water filled cylinder, varying the rod:background concentration ratios from 10:1 to 1:10 simulating a large range of biological uptake ratios. The rod phantom is then placed inside a non-uniformly shaped 500 mL breast phantom and scans are again acquired using both simple and complex 3D trajectories for similarly varying contrasts. Summed slice and contiguous multi-slice images are evaluated by five independent readers, identifying the smallest distinguishable rod for each concentration and experimental setup. Linear and quadratic regression is used to compare the resulting contrast-detail curves. Results indicate that in a moderately low-noise 500 mL background, using the SPECT camera having 2.5 mm intrinsic pixels, the mean detectable rod was approximately 3.4 mm at a 10:1 ratio, degrading to approximately 5.2 mm with the 2.5:1 concentration ratio. The smallest object detail was observed using a 45 degrees tilted trajectory acquisition. The complex 3D projected sine wave acquisition, however, had the most consistent combined intra- and inter-observer results, making it potentially the best imaging approach for consistent results.

Entities:  

Mesh:

Year:  2010        PMID: 20224159      PMCID: PMC3261230          DOI: 10.1088/0031-9155/55/7/008

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  17 in total

1.  Performance of dedicated emission mammotomography for various breast shapes and sizes.

Authors:  C N Brzymialkiewicz; M P Tornai; R L McKinley; S J Cutler; J E Bowsher
Journal:  Phys Med Biol       Date:  2006-09-19       Impact factor: 3.609

2.  Contrast-detail assessment of computed tomography scanners.

Authors:  K Faulkner; B M Moores
Journal:  Phys Med Biol       Date:  1986-09       Impact factor: 3.609

3.  (99m)Tc sestamibi breast imaging for the examination of patients with dense and fatty breasts: multicenter study.

Authors:  Iraj Khalkhali; Janet K Baum; Javier Villanueva-Meyer; Steven L Edell; Laurence G Hanelin; Carlos E Lugo; Raymond Taillefer; Leonard M Freeman; Charles E Neal; Alice M Scheff; James L Connolly; Stuart J Schnitt; Mary J Houlihan; John S Sampalis; Stephen B Haber
Journal:  Radiology       Date:  2002-01       Impact factor: 11.105

4.  99Tcm-MIBI scintimammography in 300 consecutive patients: factors that may affect accuracy.

Authors:  A Tofani; R Sciuto; A Semprebene; A Festa; R Pasqualoni; S Giunta; M Mottolese; M Benevolo; C Botti; C L Maini
Journal:  Nucl Med Commun       Date:  1999-12       Impact factor: 1.690

Review 5.  The role of (99m)Tc methoxyisobutylisonitrile in imaging breast cancer.

Authors:  A D Waxman
Journal:  Semin Nucl Med       Date:  1997-01       Impact factor: 4.446

Review 6.  The role of 99mTc-sestamibi and other conventional radiopharmaceuticals in breast cancer diagnosis.

Authors:  R Taillefer
Journal:  Semin Nucl Med       Date:  1999-01       Impact factor: 4.446

7.  Scintimammography with dedicated breast camera detects and localizes occult carcinoma.

Authors:  Leonard R Coover; Gina Caravaglia; Phyllis Kuhn
Journal:  J Nucl Med       Date:  2004-04       Impact factor: 10.057

8.  Technetium-99m-sestamibi uptake in breast tumor and associated lymph nodes.

Authors:  J Maublant; M de Latour; D Mestas; A Clemenson; S Charrier; V Feillel; G Le Bouedec; P Kaufmann; J Dauplat; A Veyre
Journal:  J Nucl Med       Date:  1996-06       Impact factor: 10.057

9.  Scintimammography with dedicated breast camera in unifocal and multifocal/multicentric primary breast cancer detection: a comparative study with SPECT.

Authors:  Angela Spanu; Pierina Cottu; Alessandra Manca; Francesca Chessa; Daniela Sanna; Giuseppe Madeddu
Journal:  Int J Oncol       Date:  2007-08       Impact factor: 5.650

10.  Technetium-99m hexakis 2-methoxyisobutyl isonitrile: human biodistribution, dosimetry, safety, and preliminary comparison to thallium-201 for myocardial perfusion imaging.

Authors:  F J Wackers; D S Berman; J Maddahi; D D Watson; G A Beller; H W Strauss; C A Boucher; M Picard; B L Holman; R Fridrich
Journal:  J Nucl Med       Date:  1989-03       Impact factor: 10.057

View more
  5 in total

1.  Characterizing the contribution of cardiac and hepatic uptake in dedicated breast SPECT using tilted trajectories.

Authors:  K L Perez; S J Cutler; P Madhav; M P Tornai
Journal:  Phys Med Biol       Date:  2010-07-30       Impact factor: 3.609

Review 2.  Radionuclide methods and instrumentation for breast cancer detection and diagnosis.

Authors:  Suleman Surti
Journal:  Semin Nucl Med       Date:  2013-07       Impact factor: 4.446

3.  Personalized estimates of radiation dose from dedicated breast CT in a diagnostic population and comparison with diagnostic mammography.

Authors:  Srinivasan Vedantham; Linxi Shi; Andrew Karellas; Avice M O'Connell; David L Conover
Journal:  Phys Med Biol       Date:  2013-10-29       Impact factor: 3.609

4.  Initial In Vivo Quantification of Tc-99m Sestamibi Uptake as a Function of Tissue Type in Healthy Breasts Using Dedicated Breast SPECT-CT.

Authors:  Steve D Mann; Kristy L Perez; Emily K E McCracken; Jainil P Shah; Terence Z Wong; Martin P Tornai
Journal:  J Oncol       Date:  2012-08-16       Impact factor: 4.375

5.  Evaluation of Cadmium-Zinc-Telluride Detector-based Single-Photon Emission Computed Tomography for Nuclear Cardiology: a Comparison with Conventional Anger Single-Photon Emission Computed Tomography.

Authors:  Takanaga Niimi; Mamoru Nanasato; Mitsuo Sugimoto; Hisatoshi Maeda
Journal:  Nucl Med Mol Imaging       Date:  2017-03-03
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.