Literature DB >> 21305601

Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3 T with radial EPI.

Himanshu Bhat1, Qi Yang, Sven Zuehlsdorff, Kuncheng Li, Debiao Li.   

Abstract

Whole-heart coronary magnetic resonance angiography is a promising method for detecting coronary artery disease. However, the imaging time is relatively long (typically 10-15 min). The goal of this study was to implement a radial echo planar imaging sequence for contrast-enhanced whole-heart coronary magnetic resonance angiography, with the aim of combining the scan efficiency of echo planar imaging with the motion insensitivity of radial k-space sampling. A self-calibrating phase correction technique was used to correct for off-resonance effects, trajectory measurement was used to correct for k-space trajectory errors, and variable density sampling was used in the partition direction to reduce streaking artifacts. Seven healthy volunteers and two patients were scanned with the proposed radial echo planar imaging sequence, and the images were compared with a traditional gradient echo and X-ray angiography techniques, respectively. Whole-heart images with the radial EPI technique were acquired with a resolution of 1.0 × 1.0 × 2.0 mm(3) in a scan time of 5 min. In healthy volunteers, the average image quality scores and visualized vessel lengths of the RCA and LAD were similar for the radial EPI and gradient echo techniques (P value > 0.05 for all). Anecdotal patient studies showed excellent agreement of the radial EPI technique with X-ray angiography.
Copyright © 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21305601      PMCID: PMC3120915          DOI: 10.1002/mrm.22781

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  30 in total

1.  Undersampled projection-reconstruction imaging for time-resolved contrast-enhanced imaging.

Authors:  K K Vigen; D C Peters; T M Grist; W F Block; C A Mistretta
Journal:  Magn Reson Med       Date:  2000-02       Impact factor: 4.668

2.  Free-breathing, three-dimensional coronary artery magnetic resonance angiography: comparison of sequences.

Authors:  Oliver M Weber; Sandra Pujadas; Alastair J Martin; Charles B Higgins
Journal:  J Magn Reson Imaging       Date:  2004-09       Impact factor: 4.813

3.  Rapid fat-suppressed isotropic steady-state free precession imaging using true 3D multiple-half-echo projection reconstruction.

Authors:  Aiming Lu; Ethan Brodsky; Thomas M Grist; Walter F Block
Journal:  Magn Reson Med       Date:  2005-03       Impact factor: 4.668

Review 4.  Coronary magnetic resonance angiography.

Authors:  Matthias Stuber; Robert G Weiss
Journal:  J Magn Reson Imaging       Date:  2007-08       Impact factor: 4.813

5.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application].

Authors:  J I Jackson; C H Meyer; D G Nishimura; A Macovski
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

6.  Theoretical aspects of motion sensitivity and compensation in echo-planar imaging.

Authors:  J L Duerk; O P Simonetti
Journal:  J Magn Reson Imaging       Date:  1991 Nov-Dec       Impact factor: 4.813

7.  Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3 T using interleaved echo planar imaging.

Authors:  Himanshu Bhat; Qi Yang; Sven Zuehlsdorff; Kuncheng Li; Debiao Li
Journal:  Invest Radiol       Date:  2010-08       Impact factor: 6.016

8.  Ultrafast interleaved gradient-echo-planar imaging on a standard scanner.

Authors:  G C McKinnon
Journal:  Magn Reson Med       Date:  1993-11       Impact factor: 4.668

9.  Whole-heart contrast-enhanced coronary magnetic resonance angiography using gradient echo interleaved EPI.

Authors:  Himanshu Bhat; Sven Zuehlsdorff; Xiaoming Bi; Debiao Li
Journal:  Magn Reson Med       Date:  2009-06       Impact factor: 4.668

10.  Whole-heart coronary magnetic resonance angiography at 3 Tesla in 5 minutes with slow infusion of Gd-BOPTA, a high-relaxivity clinical contrast agent.

Authors:  Xiaoming Bi; James C Carr; Debiao Li
Journal:  Magn Reson Med       Date:  2007-07       Impact factor: 3.737

View more
  5 in total

1.  Compressed sensing reconstruction for whole-heart imaging with 3D radial trajectories: a graphics processing unit implementation.

Authors:  Seunghoon Nam; Mehmet Akçakaya; Tamer Basha; Christian Stehning; Warren J Manning; Vahid Tarokh; Reza Nezafat
Journal:  Magn Reson Med       Date:  2012-03-05       Impact factor: 4.668

2.  Accelerated contrast-enhanced whole-heart coronary MRI using low-dimensional-structure self-learning and thresholding.

Authors:  Mehmet Akçakaya; Tamer A Basha; Raymond H Chan; Hussein Rayatzadeh; Kraig V Kissinger; Beth Goddu; Lois A Goepfert; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2012-03-05       Impact factor: 4.668

3.  Accelerated isotropic sub-millimeter whole-heart coronary MRI: compressed sensing versus parallel imaging.

Authors:  Mehmet Akçakaya; Tamer A Basha; Raymond H Chan; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

4.  ACCELERATED CORONARY MRI USING 3D SPIRIT-RAKI WITH SPARSITY REGULARIZATION.

Authors:  Seyed Amir Hossein Hosseini; Steen Moeller; Sebastian Weingärtner; Kȃmil Uǧurbil; Mehmet Akçakaya
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2019-07-11

5.  Accelerated, free-breathing, noncontrast, electrocardiograph-triggered, thoracic MR angiography with stack-of-stars k-space sampling and GRASP reconstruction.

Authors:  Hassan Haji-Valizadeh; Jeremy D Collins; Pascale J Aouad; Ali M Serhal; Marc D Lindley; Jianing Pang; Nivedita K Naresh; James C Carr; Daniel Kim
Journal:  Magn Reson Med       Date:  2018-09-05       Impact factor: 4.668

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.