Literature DB >> 15723411

Rapid fat-suppressed isotropic steady-state free precession imaging using true 3D multiple-half-echo projection reconstruction.

Aiming Lu1, Ethan Brodsky, Thomas M Grist, Walter F Block.   

Abstract

Three-dimensional projection reconstruction (3D PR)-based techniques are advantageous for steady-state free precession (SSFP) imaging for several reasons, including the capability to achieve short repetition times (TRs). In this paper, a multi-half-echo technique is presented that dramatically improves the data-sampling efficiency of 3D PR sequences while it retains this short-TR capability. The k-space trajectory deviations are measured quickly and corrected on a per-sample point basis. A two-pass RF cycling technique is then applied to the dual-half-echo implementation to generate fat/water-separated images. The resultant improvement in the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) was demonstrated in volunteer studies. Volumetric images with excellent spatial resolution, coverage, and contrast were obtained with high speed. The non-contrast-enhanced SSFP studies show that this technique has promising potential for MR angiography (MRA). (c) 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2005        PMID: 15723411     DOI: 10.1002/mrm.20389

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  21 in total

1.  The usefulness of the three-dimensional enhanced T1 high-resolution isotropic volume excitation MR in the evaluation of shoulder pathology: comparison with two-dimensional enhanced T1 fat saturation MR.

Authors:  Hee J Park; So Y Lee; Myung H Rho; Heon J Kwon; Mi S Kim; Eun C Chung
Journal:  Br J Radiol       Date:  2015-08-05       Impact factor: 3.039

2.  Abdominal fat-water separation with SSFP at 3 Tesla.

Authors:  Janaka P Wansapura
Journal:  Pediatr Radiol       Date:  2006-11-07

3.  3D hyperpolarized He-3 MRI of ventilation using a multi-echo projection acquisition.

Authors:  James H Holmes; Rafael L O'Halloran; Ethan K Brodsky; Youngkyoo Jung; Walter F Block; Sean B Fain
Journal:  Magn Reson Med       Date:  2008-05       Impact factor: 4.668

4.  Characterizing and correcting gradient errors in non-cartesian imaging: Are gradient errors linear time-invariant (LTI)?

Authors:  Ethan K Brodsky; Alexey A Samsonov; Walter F Block
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

5.  Self-calibrated multiple-echo acquisition with radial trajectories using the conjugate gradient method (SMART-CG).

Authors:  Youngkyoo Jung; Alexey A Samsonov; Mark Bydder; Walter F Block
Journal:  J Magn Reson Imaging       Date:  2011-04       Impact factor: 4.813

6.  Interest of HYPR flow dynamic MRA for characterization of cerebral arteriovenous malformations: comparison with TRICKS MRA and catheter DSA.

Authors:  Raphaël Dautry; Myriam Edjlali; Pauline Roca; Cécile Rabrait; Yijing Wu; Kevin Johnson; Olivier Wieben; Denis Trystram; Christine Rodriguez-Régent; Fawaz Alshareef; Patrick Turski; Jean-François Meder; Olivier Naggara; Catherine Oppenheim
Journal:  Eur Radiol       Date:  2015-04-28       Impact factor: 5.315

7.  Rapid time-resolved magnetic resonance angiography via a multiecho radial trajectory and GraDeS reconstruction.

Authors:  Gregory R Lee; Nicole Seiberlich; Jeffrey L Sunshine; Timothy J Carroll; Mark A Griswold
Journal:  Magn Reson Med       Date:  2012-04-03       Impact factor: 4.668

8.  Respiratory and cardiac self-gated free-breathing cardiac CINE imaging with multiecho 3D hybrid radial SSFP acquisition.

Authors:  Jing Liu; Pascal Spincemaille; Noel C F Codella; Thanh D Nguyen; Martin R Prince; Yi Wang
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

9.  Self-calibrated trajectory estimation and signal correction method for robust radial imaging using GRAPPA operator gridding.

Authors:  Anagha Deshmane; Martin Blaimer; Felix Breuer; Peter Jakob; Jeffrey Duerk; Nicole Seiberlich; Mark Griswold
Journal:  Magn Reson Med       Date:  2015-03-11       Impact factor: 4.668

10.  Improved slice selection for R2* mapping during cryoablation with eddy current compensation.

Authors:  Aiming Lu; Bruce L Daniel; John M Pauly; Kim Butts Pauly
Journal:  J Magn Reson Imaging       Date:  2008-07       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.