Literature DB >> 19319898

Whole-heart contrast-enhanced coronary magnetic resonance angiography using gradient echo interleaved EPI.

Himanshu Bhat1, Sven Zuehlsdorff, Xiaoming Bi, Debiao Li.   

Abstract

Whole-heart coronary MR angiography (MRA) is a promising method for detecting coronary artery disease. However, the imaging time is relatively long (on the order of 10-15 min). Such a long imaging time may result in patient discomfort and compromise the robustness of whole-heart coronary MRA due to increased respiratory and cardiac motion artifacts. The goal of this study was to optimize a gradient echo interleaved echo planar imaging (GRE-EPI) acquisition scheme for reducing the imaging time of contrast-enhanced whole-heart coronary MRA. Numerical simulations and phantom studies were used to optimize the GRE-EPI sequence parameters. Healthy volunteers were scanned with both the proposed GRE-EPI sequence and a 3D TrueFISP sequence for comparison purposes. Slow infusion (0.5 cc/sec) of Gd-DTPA was used to enhance the signal-to-noise ratio (SNR) of the GRE-EPI acquisition. Whole-heart images with the GRE-EPI technique were acquired with a true resolution of 1.0 x 1.1 x 2.0 mm(3) in an average scan time of 4.7 +/- 0.7 min with an average navigator efficiency of 44 +/- 6%. The GRE-EPI acquisition showed excellent delineation of all the major coronary arteries with scan time reduced by a factor of 2 compared with the TrueFISP acquisition.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19319898      PMCID: PMC2705116          DOI: 10.1002/mrm.21963

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  32 in total

1.  Coronary arteries: magnetization-prepared contrast-enhanced three-dimensional volume-targeted breath-hold MR angiography.

Authors:  D Li; J C Carr; S M Shea; J Zheng; V S Deshpande; P A Wielopolski; J P Finn
Journal:  Radiology       Date:  2001-04       Impact factor: 11.105

2.  Retrospective adaptive motion correction for navigator-gated 3D coronary MR angiography.

Authors:  Y Wang; R L Ehman
Journal:  J Magn Reson Imaging       Date:  2000-02       Impact factor: 4.813

3.  Volume coronary angiography using targeted scans (VCATS): a new strategy in MR coronary angiography.

Authors:  R J van Geuns; P A Wielopolski; A J Wardeh; H G de Bruin; M Oudkerk; P J de Feyter
Journal:  Int J Cardiovasc Imaging       Date:  2001-10       Impact factor: 2.357

4.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

5.  Clinical multishot DW-EPI through parallel imaging with considerations of susceptibility, motion, and noise.

Authors:  Stefan Skare; Rexford D Newbould; David B Clayton; Gregory W Albers; Scott Nagle; Roland Bammer
Journal:  Magn Reson Med       Date:  2007-05       Impact factor: 4.668

Review 6.  Coronary magnetic resonance angiography.

Authors:  Matthias Stuber; Robert G Weiss
Journal:  J Magn Reson Imaging       Date:  2007-08       Impact factor: 4.813

7.  Theoretical aspects of motion sensitivity and compensation in echo-planar imaging.

Authors:  J L Duerk; O P Simonetti
Journal:  J Magn Reson Imaging       Date:  1991 Nov-Dec       Impact factor: 4.813

8.  Breath-hold coronary MR angiography with volume-targeted imaging.

Authors:  P A Wielopolski; R J van Geuns; P J de Feyter; M Oudkerk
Journal:  Radiology       Date:  1998-10       Impact factor: 11.105

9.  Preliminary report on in vivo coronary MRA at 3 Tesla in humans.

Authors:  Matthias Stuber; René M Botnar; Stefan E Fischer; Rolf Lamerichs; Jouke Smink; Paul Harvey; Warren J Manning
Journal:  Magn Reson Med       Date:  2002-09       Impact factor: 4.668

10.  Whole-heart coronary magnetic resonance angiography at 3 Tesla in 5 minutes with slow infusion of Gd-BOPTA, a high-relaxivity clinical contrast agent.

Authors:  Xiaoming Bi; James C Carr; Debiao Li
Journal:  Magn Reson Med       Date:  2007-07       Impact factor: 3.737

View more
  4 in total

1.  Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3 T using interleaved echo planar imaging.

Authors:  Himanshu Bhat; Qi Yang; Sven Zuehlsdorff; Kuncheng Li; Debiao Li
Journal:  Invest Radiol       Date:  2010-08       Impact factor: 6.016

2.  Subject-specific estimation of respiratory navigator tracking factor for free-breathing cardiovascular MR.

Authors:  Mehdi H Moghari; Peng Hu; Kraig V Kissinger; Beth Goddu; Lois Goepfert; Long Ngo; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2011-08-29       Impact factor: 4.668

3.  Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3 T with radial EPI.

Authors:  Himanshu Bhat; Qi Yang; Sven Zuehlsdorff; Kuncheng Li; Debiao Li
Journal:  Magn Reson Med       Date:  2011-02-08       Impact factor: 4.668

4.  Efficient correction of inhomogeneous static magnetic field-induced distortion in Echo Planar Imaging.

Authors:  Dominic Holland; Joshua M Kuperman; Anders M Dale
Journal:  Neuroimage       Date:  2009-11-26       Impact factor: 6.556

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.