Potential benefits from deeply inserted cochlear implant electrodes.

Paul J Boyd1.   

Abstract

OBJECTIVES: This review examines evidence for potential benefits of using cochlear implant electrodes that extend into the apical regions of the cochlea. Most cochlear implant systems use electrode arrays that extend 1 to 1.5 turns from the basal cochleostomy, but one manufacturer (MED-EL GmbH) uses an electrode array that is considerably longer. The fundamental rationale for using electrodes extending toward the apex of the cochlea is to provide additional low-pitched auditory percepts and thereby increase the spectral information available to the user. Several experimental long arrays have also been produced by other manufacturers to assess potential benefits of this approach.
DESIGN: In addition to assessing the effects of deeply inserted electrodes on performance, this review examines several underlying and associated issues, including cochlear anatomy, electrode design, surgical considerations (including insertion trauma), and pitch scaling trials. Where possible, the aim is to draw conclusions regarding the potential from apical electrodes in general, rather than relating to the performance of specific and current devices.
RESULTS: Imaging studies indicate that currently available electrode arrays rarely extend more than two turns into the cochlea, the mean insertion angle for full insertions of the MED-EL electrodes being about 630°. This is considerably shorter than the total length of the cochlea and more closely approximates the length of the spiral ganglion. Anatomical considerations, and some modelling studies, suggest that fabrication of even longer electrodes is unlikely to provide additional spectral information. The issue of potential benefit from the most apical electrodes, therefore, is whether they are able to selectively stimulate discrete and tonotopically ordered neural populations near the apex of the spiral ganglion, where the ganglion cells are closely grouped. Pitch scaling studies, using the MED-EL and experimental long arrays, suggest that this is achieved in many cases, but that a significant number of individuals show evidence of pitch confusions or reversals among the most apical electrodes, presumably reducing potential performance benefit and presenting challenges for processor programming.
CONCLUSIONS: Benefits in terms of speech recognition and other performance measures are less clear. Several studies have indicated that deactivation of apical electrodes results in poorer speech recognition performance, but these have been mostly acute studies where the subjects have been accustomed to the full complement of electrodes, thus making interpretation difficult. Some chronic studies have suggested that apical electrodes do provide additional performance benefit, but others have shown performance improvement after deactivating some of the apical electrodes. Whether or not deeply inserted electrodes can offer performance benefits, there is evidence that currently available designs tend to produce more intracochlear trauma than shorter arrays, in terms of loss of residual acoustic hearing and reduction of the neural substrate. This may have important long-term consequences for the user. Furthermore, as it is possible that subjects with better low-frequency residual hearing are more likely to benefit from the inclusion of apical electrodes, there may be a potential clinical dilemma as the same subjects are those most likely to benefit from bimodal electroacoustic stimulation, requiring a relatively shallow insertion.

Entities:  

Mesh:

Year:  2011        PMID: 21248642     DOI: 10.1097/AUD.0b013e3182064bda

Source DB:  PubMed          Journal:  Ear Hear        ISSN: 0196-0202            Impact factor:   3.570


  11 in total

1.  CT-scan contouring technique allows for direct and reliable measurements of the cochlear duct length: implication in cochlear implantation with straight electrode-arrays.

Authors:  Thi Hau Vu; Chiara Perazzini; Mathilde Puechmaille; Aurélie Bachy; Aurélien Mulliez; Louis Boyer; Thierry Mom; Jean Gabrillargues
Journal:  Eur Arch Otorhinolaryngol       Date:  2019-04-22       Impact factor: 2.503

2.  Perceptual changes in place of stimulation with long cochlear implant electrode arrays.

Authors:  David M Landsberger; Griet Mertens; Andrea Kleine Punte; Paul Van De Heyning
Journal:  J Acoust Soc Am       Date:  2014-02       Impact factor: 1.840

3.  Cochlear implantation with the nucleus slim modiolar electrode (CI532): a preliminary experience.

Authors:  Domenico Cuda; Alessandra Murri
Journal:  Eur Arch Otorhinolaryngol       Date:  2017-10-14       Impact factor: 2.503

4.  The Relationship Between Insertion Angles, Default Frequency Allocations, and Spiral Ganglion Place Pitch in Cochlear Implants.

Authors:  David M Landsberger; Maja Svrakic; J Thomas Roland; Mario Svirsky
Journal:  Ear Hear       Date:  2015 Sep-Oct       Impact factor: 3.570

5.  Computational Models for Predicting Outcomes of Neuroprosthesis Implantation: the Case of Cochlear Implants.

Authors:  Mario Ceresa; Nerea Mangado; Russell J Andrews; Miguel A Gonzalez Ballester
Journal:  Mol Neurobiol       Date:  2015-06-18       Impact factor: 5.590

6.  Random walks with shape prior for cochlea segmentation in ex vivo μCT.

Authors:  Esmeralda Ruiz Pujadas; Hans Martin Kjer; Gemma Piella; Mario Ceresa; Miguel Angel González Ballester
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-03-19       Impact factor: 2.924

7.  A novel perfusion-based method for cochlear implant electrode insertion.

Authors:  Sushrut Kale; Vanessa M Cervantes; Mailing R Wu; Dominic V Pisano; Nakul Sheth; Elizabeth S Olson
Journal:  Hear Res       Date:  2014-05-29       Impact factor: 3.208

8.  Incidence of Complete Insertion in Cochlear Implant Recipients of Long Lateral Wall Arrays.

Authors:  Michael W Canfarotta; Margaret T Dillon; Kevin D Brown; Harold C Pillsbury; Matthew M Dedmon; Brendan P O'Connell
Journal:  Otolaryngol Head Neck Surg       Date:  2021-02-16       Impact factor: 5.591

Review 9.  Electroacoustic stimulation: now and into the future.

Authors:  S Irving; L Gillespie; R Richardson; D Rowe; J B Fallon; A K Wise
Journal:  Biomed Res Int       Date:  2014-09-04       Impact factor: 3.411

10.  The Effect of Cochlear Size on Cochlear Implantation Outcomes.

Authors:  Jafri Kuthubutheen; Amandeep Grewal; Sean Symons; Julian Nedzelski; David Shipp; Vincent Lin; Joseph Chen
Journal:  Biomed Res Int       Date:  2019-06-04       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.