Literature DB >> 21246391

Comparative study of application accuracy of two frameless neuronavigation systems: experimental error assessment quantifying registration methods and clinically influencing factors.

Dimitrios Paraskevopoulos1, Andreas Unterberg, Roland Metzner, Jens Dreyhaupt, Georg Eggers, Christian Rainer Wirtz.   

Abstract

This study aimed at comparing the accuracy of two commercial neuronavigation systems. Error assessment and quantification of clinical factors and surface registration, often resulting in decreased accuracy, were intended. Active (Stryker Navigation) and passive (VectorVision Sky, BrainLAB) neuronavigation systems were tested with an anthropomorphic phantom with a deformable layer, simulating skin and soft tissue. True coordinates measured by computer numerical control were compared with coordinates on image data and during navigation, to calculate software and system accuracy respectively. Comparison of image and navigation coordinates was used to evaluate navigation accuracy. Both systems achieved an overall accuracy of <1.5 mm. Stryker achieved better software accuracy, whereas BrainLAB better system and navigation accuracy. Factors with conspicuous influence (P<0.01) were imaging, instrument replacement, sterile cover drape and geometry of instruments. Precision data indicated by the systems did not reflect measured accuracy in general. Surface matching resulted in no improvement of accuracy, confirming former studies. Laser registration showed no differences compared to conventional pointers. Differences between the two systems were limited. Surface registration may improve inaccurate point-based registrations but does not in general affect overall accuracy. Accuracy feedback by the systems does not always match with true target accuracy and requires critical evaluation from the surgeon.

Mesh:

Year:  2011        PMID: 21246391     DOI: 10.1007/s10143-010-0302-5

Source DB:  PubMed          Journal:  Neurosurg Rev        ISSN: 0344-5607            Impact factor:   3.042


  44 in total

1.  Accuracy and clinical applicability of a passive marker based frameless neuronavigation system.

Authors:  A Muacevic; E Uhl; H J Steiger; H J Reulen
Journal:  J Clin Neurosci       Date:  2000-09       Impact factor: 1.961

Review 2.  [First steps in neuronavigation].

Authors:  J M Castilla; V Martín; O Fernández-Arconada; P Delgado; A Rodríguez-Salazar
Journal:  Neurocirugia (Astur)       Date:  2003-10       Impact factor: 0.553

3.  Frameless image guidance improves accuracy in three-dimensional interstitial brachytherapy needle placement.

Authors:  Robert Krempien; Stefan Hassfeld; Josef Kozak; Hans-Peter Tuemmler; Sascha Däuber; Martina Treiber; Juergen Debus; Wolfgang Harms
Journal:  Int J Radiat Oncol Biol Phys       Date:  2004-12-01       Impact factor: 7.038

4.  Template-based registration for image-guided maxillofacial surgery.

Authors:  Georg Eggers; Joachim Mühling; Rüdiger Marmulla
Journal:  J Oral Maxillofac Surg       Date:  2005-09       Impact factor: 1.895

5.  Accuracy of registration methods in frameless stereotaxis.

Authors:  P A Helm; T S Eckel
Journal:  Comput Aided Surg       Date:  1998

6.  In vivo accuracy testing and clinical experience with the ISG Viewing Wand.

Authors:  E P Sipos; S A Tebo; S J Zinreich; D M Long; H Brem
Journal:  Neurosurgery       Date:  1996-07       Impact factor: 4.654

7.  Clinical application of neuro-navigation in a series of single burr-hole procedures.

Authors:  W Tirakotai; T Riegel; U Sure; O Bozinov; D Hellwig; H Bertalanffy
Journal:  Zentralbl Neurochir       Date:  2004-05

8.  Fiducial versus nonfiducial neuronavigation registration assessment and considerations of accuracy.

Authors:  Wolfgang K Pfisterer; Stephen Papadopoulos; Denise A Drumm; Kris Smith; Mark C Preul
Journal:  Neurosurgery       Date:  2008-03       Impact factor: 4.654

9.  Application accuracy in frameless image-guided neurosurgery: a comparison study of three patient-to-image registration methods.

Authors:  Peter A Woerdeman; Peter W A Willems; Herke J Noordmans; Cornelis A F Tulleken; Jan Willem Berkelbach van der Sprenkel
Journal:  J Neurosurg       Date:  2007-06       Impact factor: 5.115

10.  Accuracy and clinical use of a novel aiming device for frameless stereotactic brain biopsy.

Authors:  G Widmann; W Eisner; P Kovacs; T Fiegele; M Ortler; T B Lang; R Stoffner; R Bale
Journal:  Minim Invasive Neurosurg       Date:  2008-12-05
View more
  11 in total

Review 1.  [The hybrid operating room. Home of high-end intraoperative imaging].

Authors:  F Gebhard; C Riepl; P Richter; A Liebold; H Gorki; R Wirtz; R König; F Wilde; A Schramm; M Kraus
Journal:  Unfallchirurg       Date:  2012-02       Impact factor: 1.000

Review 2.  [Intraoperative navigation, with focus on the skull base].

Authors:  C R Wirtz
Journal:  HNO       Date:  2016-09       Impact factor: 1.284

3.  Navigation Guidance During Free Flap Mandibular Reconstruction: A Cadaveric Trial.

Authors:  R Alex Harbison; Xiao-Feng Shan; Zachary Douglas; Scott Bevans; Yangming Li; Kris S Moe; Neal Futran; Jeffrey J Houlton
Journal:  JAMA Otolaryngol Head Neck Surg       Date:  2017-03-01       Impact factor: 6.223

4.  Analysis of intrafraction motion in CyberKnife-based stereotaxy using mask based immobilization and 6D-skull tracking.

Authors:  Tejinder Kataria; Kushal Narang; Deepak Gupta; Shyam S Bisht; Ashu Abhishek; Shikha Goyal; Trinanjan Basu; K P Karrthick
Journal:  J Radiosurg SBRT       Date:  2016

5.  Image-Based Navigation for Functional Endoscopic Sinus Surgery Using Structure From Motion.

Authors:  Simon Leonard; Austin Reiter; Ayushi Sinha; Masaru Ishii; Russel H Taylor; Gregory D Hager
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-21

6.  Autonomous neuro-registration for robot-based neurosurgery.

Authors:  Abhishek Kaushik; T A Dwarakanath; Gaurav Bhutani
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-07-20       Impact factor: 2.924

7.  Stereotactic co-axial projection imaging for augmented reality neuronavigation: a proof-of-concept study.

Authors:  Bingxuan Wu; Peng Liu; Chi Xiong; Chenmeng Li; Fan Zhang; Shuwei Shen; Pengfei Shao; Peng Yao; Chaoshi Niu; Ronald Xu
Journal:  Quant Imaging Med Surg       Date:  2022-07

8.  Regional-surface-based registration for image-guided neurosurgery: effects of scan modes on registration accuracy.

Authors:  Yuan Dong; Chenxi Zhang; Dafeng Ji; Manning Wang; Zhijian Song
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-05-04       Impact factor: 2.924

9.  Stereotactic Placement of Intratumoral Catheters for Continuous Infusion Delivery of Herpes Simplex Virus -1 G207 in Pediatric Malignant Supratentorial Brain Tumors.

Authors:  Joshua D Bernstock; Zachary Wright; Asim K Bag; Florian Gessler; George Yancey Gillespie; James M Markert; Gregory K Friedman; James M Johnston
Journal:  World Neurosurg       Date:  2018-11-24       Impact factor: 2.104

10.  Current accuracy of surface matching compared to adhesive markers in patient-to-image registration.

Authors:  Mireli A Mongen; Peter W A Willems
Journal:  Acta Neurochir (Wien)       Date:  2019-03-16       Impact factor: 2.216

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.