Literature DB >> 19061150

Accuracy and clinical use of a novel aiming device for frameless stereotactic brain biopsy.

G Widmann1, W Eisner, P Kovacs, T Fiegele, M Ortler, T B Lang, R Stoffner, R Bale.   

Abstract

Aiming devices enable the use of neuronavigation systems for rigid instrument guidance mimicking the possibilities of a frame-based system without having a stereotactic frame affixed to the skull. The aim of the presented work was to investigate the phantom targeting accuracy of the Vertek aiming device (Medtronic Inc., Louisville, USA) and whether it can be safely and accurately applied in a concept of minimally invasive brain biopsy in which multi-modal image fusion, image-to-patient registration and head immobilization were based on a non-invasive vacuum mouthpiece. A plastic model of a head with 20 target beads broadly distributed around the head volume was used for determination of CT-based targeting accuracy. Every target was punctured 5 times totaling 100 needle positionings. Accuracy was evaluated on postoperative CT scans with the needles in place. The mean normal deviation (n = 100) was 1.5 +/- 0.8 mm and the mean angle of deviation was 1.1 +/- 0.7 degrees. In a preliminary clinical series in ten patients diagnostic biopsy sampling of intracranial lesions with a median diameter of 28 mm (range: 12-90 mm) could be achieved in all patients and no biopsy related complications were recorded. The experimental results showed a similar accuracy to frame-based stereotaxy. The device facilitates trajectory alignment via two pivot joints and the actual depth and location of the biopsy needle can be monitored. Within the limitations of a preliminary study, brain biopsy may be accurately and safely performed for lesions > or = 12 mm.

Entities:  

Mesh:

Year:  2008        PMID: 19061150     DOI: 10.1055/s-0028-1085424

Source DB:  PubMed          Journal:  Minim Invasive Neurosurg        ISSN: 0946-7211


  6 in total

1.  Laser-assisted flat-detector CT-guided intracranial access.

Authors:  Daniel L Cooke; Michael R Levitt; Louis J Kim; Danial K Hallam; Laligam N Sekhar; Basavaraj V Ghodke
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-08-05       Impact factor: 2.924

2.  Integration of the Image-Guided Surgery Toolkit (IGSTK) into the Medical Imaging Interaction Toolkit (MITK).

Authors:  Tong Lu; Ping Liang; Wen-Bo Wu; Jin Xue; Cheng-Long Lei; Yin-Yan Li; Yun-Na Sun; Fang-Yi Liu
Journal:  J Digit Imaging       Date:  2012-12       Impact factor: 4.056

3.  Comparative study of application accuracy of two frameless neuronavigation systems: experimental error assessment quantifying registration methods and clinically influencing factors.

Authors:  Dimitrios Paraskevopoulos; Andreas Unterberg; Roland Metzner; Jens Dreyhaupt; Georg Eggers; Christian Rainer Wirtz
Journal:  Neurosurg Rev       Date:  2011-01-19       Impact factor: 3.042

4.  Accuracy of flat panel detector CT with integrated navigational software with and without MR fusion for single-pass needle placement.

Authors:  Marc C Mabray; Sanjit Datta; Prasheel V Lillaney; Teri Moore; Sonja Gehrisch; Jason F Talbott; Michael R Levitt; Basavaraj V Ghodke; Paul S Larson; Daniel L Cooke
Journal:  J Neurointerv Surg       Date:  2015-06-05       Impact factor: 5.836

5.  Accuracy of a magnetic resonance imaging-based 3D printed stereotactic brain biopsy device in dogs.

Authors:  Sarah Gutmann; Dirk Winkler; Marcel Müller; Robert Möbius; Jean-Pierre Fischer; Peter Böttcher; Ingmar Kiefer; Ronny Grunert; Thomas Flegel
Journal:  J Vet Intern Med       Date:  2020-02-24       Impact factor: 3.333

6.  Stereotactic Neuro-Navigation Phantom Designs: A Systematic Review.

Authors:  Marko Švaco; Ivan Stiperski; Domagoj Dlaka; Filip Šuligoj; Bojan Jerbić; Darko Chudy; Marina Raguž
Journal:  Front Neurorobot       Date:  2020-10-23       Impact factor: 2.650

  6 in total