Literature DB >> 9784952

Accuracy of registration methods in frameless stereotaxis.

P A Helm1, T S Eckel.   

Abstract

The accuracy of image to patient registration is a critical issue in the intraoperative use of frameless stereotaxic instruments for surgical guidance. This study was performed to assess the accuracy of image to head phantom registration using several standard registration techniques and a clinical frameless stereotaxic instrument. Two types of radioopaque fiducial markers were fixed to a plastic head phantom, and a computed tomography scan of the phantom was performed in the routine fashion. Image to phantom registration was carried out using fiducial markers, fiducial markers plus surface fit, anatomic landmarks, and anatomic landmarks plus surface fit. After each registration, linear inaccuracy measurements were performed for each of 32 markers. Each registration was performed 10 times, and the overall mean error measurements and anterior and posterior error were computed and compared. The overall mean error was smallest for the fiducial registration alone (2.07 mm). The magnitude of error increased significantly for posterior locations for all other registration techniques, but it was not significantly increased for the fiducial registration method. For this hardware configuration, registration with surface-applied fiducial markers is measurably more accurate than registration with surface anatomic landmarks. The addition of surface points to the fiducial registration does not increase the registration accuracy but, in fact, increases the degree of error.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9784952     DOI: 10.1002/(SICI)1097-0150(1998)3:2<51::AID-IGS1>3.0.CO;2-J

Source DB:  PubMed          Journal:  Comput Aided Surg        ISSN: 1092-9088


  14 in total

Review 1.  Computer-aided navigation in neurosurgery.

Authors:  P Grunert; K Darabi; J Espinosa; R Filippi
Journal:  Neurosurg Rev       Date:  2003-05       Impact factor: 3.042

2.  Marker-free registration for the accurate integration of CT images and the subject's anatomy during navigation surgery of the maxillary sinus.

Authors:  S-H Kang; M-K Kim; J-H Kim; H-K Park; W Park
Journal:  Dentomaxillofac Radiol       Date:  2012-04-12       Impact factor: 2.419

3.  Comparative study of application accuracy of two frameless neuronavigation systems: experimental error assessment quantifying registration methods and clinically influencing factors.

Authors:  Dimitrios Paraskevopoulos; Andreas Unterberg; Roland Metzner; Jens Dreyhaupt; Georg Eggers; Christian Rainer Wirtz
Journal:  Neurosurg Rev       Date:  2011-01-19       Impact factor: 3.042

4.  Image Updating for Brain Shift Compensation During Resection.

Authors:  Xiaoyao Fan; David W Roberts; Jonathan D Olson; Songbai Ji; Timothy J Schaewe; David A Simon; Keith D Paulsen
Journal:  Oper Neurosurg (Hagerstown)       Date:  2018-04-01       Impact factor: 2.703

5.  Intraoperative fiducial-less patient registration using volumetric 3D ultrasound: a prospective series of 32 neurosurgical cases.

Authors:  Xiaoyao Fan; David W Roberts; Songbai Ji; Alex Hartov; Keith D Paulsen
Journal:  J Neurosurg       Date:  2015-07-03       Impact factor: 5.115

6.  Intraoperative patient registration using volumetric true 3D ultrasound without fiducials.

Authors:  Songbai Ji; David W Roberts; Alex Hartov; Keith D Paulsen
Journal:  Med Phys       Date:  2012-12       Impact factor: 4.071

7.  Comparison of registration accuracy of skin- and bone-implanted fiducials for frameless stereotaxis of the brain: a prospective study.

Authors:  Mario Ammirati; Jeffrey D Gross; Giuseppe Ammirati; Sharon Dugan
Journal:  Skull Base       Date:  2002-08

8.  Intraoperative image updating for brain shift following dural opening.

Authors:  Xiaoyao Fan; David W Roberts; Timothy J Schaewe; Songbai Ji; Leslie H Holton; David A Simon; Keith D Paulsen
Journal:  J Neurosurg       Date:  2016-09-09       Impact factor: 5.115

9.  Data assimilation using a gradient descent method for estimation of intraoperative brain deformation.

Authors:  Songbai Ji; Alex Hartov; David Roberts; Keith Paulsen
Journal:  Med Image Anal       Date:  2009-07-09       Impact factor: 8.545

Review 10.  Frame-based stereotaxy in a frameless era: current capabilities, relative role, and the positive- and negative predictive values of blood through the needle.

Authors:  Christopher M Owen; Mark E Linskey
Journal:  J Neurooncol       Date:  2009-05-09       Impact factor: 4.130

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.