Literature DB >> 22576897

Analysis of intra-aneurysmal flow for cerebral aneurysms with cerebral angiography.

L-D Jou1, M E Mawad.   

Abstract

BACKGROUND AND
PURPOSE: Hemodynamics is an important factor in the development and rupture of cerebral aneurysms. Current techniques for measuring blood flow in cerebral aneurysms suffer from various limitations and have not been able to address our clinical needs. A new technique has been developed for effective evaluation of intra-aneurysmal flow based on high-frame-rate cerebral angiography, especially for flow-diverters.
MATERIALS AND METHODS: Six patients with 7 unruptured ICA aneurysms were imaged with a specially designed DSA protocol (a 3D DSA and a 2D DSA acquired at 30 frames/s, with a 2-mL/s contrast injection rate). Images of these cases were analyzed to determine the intra-aneurysmal flow based on the newly developed technique. Patient-specific aneurysm models were used for CFD calculation, and intra-aneurysmal flow rates were computed numerically. The intra-aneurysmal flow rates from the 2 methods were then compared.
RESULTS: There is a linear relationship between intra-aneurysmal flow ratios obtained from high-frame-rate cerebral angiography and CFD calculation (R = 0.99). A high frame rate (30 frames/s) provides a better estimate of intra-aneurysmal flow than low frame rates (7.5 frames/s and 15 frames/s).
CONCLUSIONS: The CFD calculation validates the estimate of intra-aneurysmal hemodynamics from cerebral angiography. The linear relationship obtained by using these 2 techniques can be used for real-time assessment of intra-aneurysmal hemodynamics for cerebral aneurysms.

Entities:  

Mesh:

Year:  2012        PMID: 22576897      PMCID: PMC7964748          DOI: 10.3174/ajnr.A3057

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  17 in total

Review 1.  X-ray videodensitometric methods for blood flow and velocity measurement: a critical review of literature.

Authors:  S D Shpilfoygel; R A Close; D J Valentino; G R Duckwiler
Journal:  Med Phys       Date:  2000-09       Impact factor: 4.071

2.  X-ray velocimetry and haemodynamic forces within a stenosed femoral model at physiological flow rates.

Authors:  R Aidan Jamison; Stephen Dubsky; Karen K W Siu; Kerry Hourigan; Andreas Fouras
Journal:  Ann Biomed Eng       Date:  2011-02-04       Impact factor: 3.934

3.  Physical factors in the initiation, growth, and rupture of human intracranial saccular aneurysms.

Authors:  G G Ferguson
Journal:  J Neurosurg       Date:  1972-12       Impact factor: 5.115

4.  Quantitative characterization of the hemodynamic environment in ruptured and unruptured brain aneurysms.

Authors:  J R Cebral; F Mut; J Weir; C Putman
Journal:  AJNR Am J Neuroradiol       Date:  2010-12-02       Impact factor: 3.825

5.  Determination of relative blood flow in single arteries: new video dilution technique.

Authors:  B M Lantz; J M Foerster; D P Link; J W Holcroft
Journal:  AJR Am J Roentgenol       Date:  1980-06       Impact factor: 3.959

6.  Hemodynamic-morphologic discriminants for intracranial aneurysm rupture.

Authors:  Jianping Xiang; Sabareesh K Natarajan; Markus Tremmel; Ding Ma; J Mocco; L Nelson Hopkins; Adnan H Siddiqui; Elad I Levy; Hui Meng
Journal:  Stroke       Date:  2010-11-24       Impact factor: 7.914

7.  Evaluation of intraaneurysmal blood velocity by time-density curve analysis and digital subtraction angiography.

Authors:  H Tenjin; F Asakura; Y Nakahara; K Matsumoto; T Matsuo; F Urano; S Ueda
Journal:  AJNR Am J Neuroradiol       Date:  1998-08       Impact factor: 3.825

8.  Stability of pulsatile blood flow at the ostium of cerebral aneurysms.

Authors:  Aishwarya R Mantha; Goetz Benndorf; Andres Hernandez; Ralph W Metcalfe
Journal:  J Biomech       Date:  2009-04-23       Impact factor: 2.712

9.  Image-based computational simulation of flow dynamics in a giant intracranial aneurysm.

Authors:  David A Steinman; Jaques S Milner; Chris J Norley; Stephen P Lownie; David W Holdsworth
Journal:  AJNR Am J Neuroradiol       Date:  2003-04       Impact factor: 3.825

10.  Angiographic assessment of the performance of flow divertors to treat cerebral aneurysms.

Authors:  Chander Sadasivan; Baruch B Lieber; Liliana Cesar; Laszlo Miskolczi; Jaehoon Seong; Ajay K Wakhloo
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006
View more
  2 in total

1.  In vitro digital subtraction angiographic evaluation of flow diverters in a patient-specific aneurysm.

Authors:  Liang-Der Jou
Journal:  Interv Neuroradiol       Date:  2017-01-01       Impact factor: 1.610

2.  In vitro investigation of contrast flow jet timing in patient-specific intracranial aneurysms.

Authors:  Liang-der Jou; Virendra R Desai; Garvin W Britz
Journal:  Quant Imaging Med Surg       Date:  2016-04
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.