Literature DB >> 17183132

Respiratory motion correction for PET oncology applications using affine transformation of list mode data.

F Lamare1, T Cresson, J Savean, C Cheze Le Rest, A J Reader, D Visvikis.   

Abstract

Respiratory motion is a source of artefacts and reduced image quality in PET. Proposed methodology for correction of respiratory effects involves the use of gated frames, which are however of low signal-to-noise ratio. Therefore a method accounting for respiratory motion effects without affecting the statistical quality of the reconstructed images is necessary. We have implemented an affine transformation of list mode data for the correction of respiratory motion over the thorax. The study was performed using datasets of the NCAT phantom at different points throughout the respiratory cycle. List mode data based PET simulated frames were produced by combining the NCAT datasets with a Monte Carlo simulation. Transformation parameters accounting for respiratory motion were estimated according to an affine registration and were subsequently applied on the original list mode data. The corrected and uncorrected list mode datasets were subsequently reconstructed using the one-pass list mode EM (OPL-EM) algorithm. Comparison of corrected and uncorrected respiratory motion average frames suggests that an affine transformation in the list mode data prior to reconstruction can produce significant improvements in accounting for respiratory motion artefacts in the lungs and heart. However, the application of a common set of transformation parameters across the imaging field of view does not significantly correct the respiratory effects on organs such as the stomach, liver or spleen.

Mesh:

Year:  2006        PMID: 17183132     DOI: 10.1088/0031-9155/52/1/009

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  22 in total

Review 1.  PET/MRI hybrid imaging: devices and initial results.

Authors:  Bernd J Pichler; Martin S Judenhofer; Hans F Wehrl
Journal:  Eur Radiol       Date:  2008-03-21       Impact factor: 5.315

2.  Local motion correction for lung tumours in PET/CT--first results.

Authors:  Ralph A Bundschuh; Axel Martínez-Möller; Markus Essler; Stephan G Nekolla; Sibylle I Ziegler; Markus Schwaiger
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-08-06       Impact factor: 9.236

3.  Respiratory-induced errors in tumor quantification and delineation in CT attenuation-corrected PET images: effects of tumor size, tumor location, and respiratory trace: a simulation study using the 4D XCAT phantom.

Authors:  Parham Geramifar; Mojtaba Shamsaie Zafarghandi; Pardis Ghafarian; Arman Rahmim; Mohammad Reza Ay
Journal:  Mol Imaging Biol       Date:  2013-12       Impact factor: 3.488

4.  Nonrigid PET motion compensation in the lower abdomen using simultaneous tagged-MRI and PET imaging.

Authors:  B Guérin; S Cho; S Y Chun; X Zhu; N M Alpert; G El Fakhri; T Reese; C Catana
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

5.  Quantitative simultaneous positron emission tomography and magnetic resonance imaging.

Authors:  Jinsong Ouyang; Yoann Petibon; Chuan Huang; Timothy G Reese; Aleksandra L Kolnick; Georges El Fakhri
Journal:  J Med Imaging (Bellingham)       Date:  2014-11-03

6.  Attenuation correction in 4D-PET using a single-phase attenuation map and rigidity-adaptive deformable registration.

Authors:  Faraz Kalantari; Jing Wang
Journal:  Med Phys       Date:  2017-02-03       Impact factor: 4.071

7.  A simple regularizer for B-spline nonrigid image registration that encourages local invertibility.

Authors:  Se Young Chun; Jeffrey A Fessler
Journal:  IEEE J Sel Top Signal Process       Date:  2009-02-01       Impact factor: 6.856

8.  Pulmonary imaging using respiratory motion compensated simultaneous PET/MR.

Authors:  Joyita Dutta; Chuan Huang; Quanzheng Li; Georges El Fakhri
Journal:  Med Phys       Date:  2015-07       Impact factor: 4.071

9.  Implementation of an automated respiratory amplitude gating technique for PET/CT: clinical evaluation.

Authors:  Guoping Chang; Tingting Chang; Tinsu Pan; John W Clark; Osama R Mawlawi
Journal:  J Nucl Med       Date:  2009-12-15       Impact factor: 10.057

10.  LROC Investigation of Three Strategies for Reducing the Impact of Respiratory Motion on the Detection of Solitary Pulmonary Nodules in SPECT.

Authors:  Mark S Smyczynski; Howard C Gifford; Joyoni Dey; Andre Lehovich; Joseph E McNamara; W Paul Segars; Michael A King
Journal:  IEEE Trans Nucl Sci       Date:  2016-02-15       Impact factor: 1.679

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.