Automatic detection of motion artifacts in the ballistocardiogram measured on a modified bathroom scale.

Richard M Wiard1, Omer T Inan, Brian Argyres, Mozziyar Etemadi, Gregory T A Kovacs, Laurent Giovangrandi.   

Abstract

Ballistocardiography (BCG) is a non-invasive technique used to measure the ejection force of blood into the aorta which can be used to estimate cardiac output and contractility change. In this work, a noise sensor was embedded in a BCG measurement system to detect excessive motion from standing subjects. For nine healthy subjects, the cross-correlation of the motion signal to the BCG noise--estimated using a simultaneously acquired electrocardiogram and statistics of the BCG signal--was found to be 0.94 and 0.87, during periods of standing still and with induced motion artifacts, respectively. In a separate study, where 35 recordings were taken from seven subjects, a threshold-based algorithm was used to flag motion-corrupted segments of the BCG signal using only the auxiliary motion sensor. Removing these flagged segments enhanced the BCG signal-to-noise ratio (SNR) by an average of 14 dB (P < 0.001). This integrated motion-sensing technique addresses a gap in methods available to identify and remove noise in standing BCG recordings due to movement, in a practical manner that does not require user intervention or obtrusive sensing.

Mesh:

Year:  2010        PMID: 21153058     DOI: 10.1007/s11517-010-0722-y

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  15 in total

1.  Kinematic and kinetic validity of the inverted pendulum model in quiet standing.

Authors:  William H Gage; David A Winter; James S Frank; Allan L Adkin
Journal:  Gait Posture       Date:  2004-04       Impact factor: 2.840

2.  Unobtrusive approaches to monitoring vital signs at home.

Authors:  Masa Ishijima
Journal:  Med Biol Eng Comput       Date:  2007-09-26       Impact factor: 2.602

3.  Non-invasive cardiac output trending during exercise recovery on a bathroom-scale-based ballistocardiograph.

Authors:  O T Inan; M Etemadi; A Paloma; L Giovangrandi; G T A Kovacs
Journal:  Physiol Meas       Date:  2009-02-06       Impact factor: 2.833

4.  Robust ballistocardiogram acquisition for home monitoring.

Authors:  O T Inan; M Etemadi; R M Wiard; L Giovangrandi; G T A Kovacs
Journal:  Physiol Meas       Date:  2009-01-16       Impact factor: 2.833

5.  Novel methods for estimating the ballistocardiogram signal using a simultaneously acquired electrocardiogram.

Authors:  Omer T Inan; Mozziyar Etemadi; Richard M Wiard; Gregory T A Kovacs; Laurent Giovangrandi
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

6.  Patterns of weight change preceding hospitalization for heart failure.

Authors:  Sarwat I Chaudhry; Yongfei Wang; John Concato; Thomas M Gill; Harlan M Krumholz
Journal:  Circulation       Date:  2007-09-10       Impact factor: 29.690

7.  Stiffness control of balance in quiet standing.

Authors:  D A Winter; A E Patla; F Prince; M Ishac; K Gielo-Perczak
Journal:  J Neurophysiol       Date:  1998-09       Impact factor: 2.714

8.  A new method for long-term monitoring of the ballistocardiogram, heart rate, and respiration.

Authors:  J Alihanka; K Vaahtoranta; I Saarikivi
Journal:  Am J Physiol       Date:  1981-05

Review 9.  The burden of chronic congestive heart failure in older persons: magnitude and implications for policy and research.

Authors:  Frederick A Masoudi; Edward P Havranek; Harlan M Krumholz
Journal:  Heart Fail Rev       Date:  2002-01       Impact factor: 4.214

10.  Estimation of central aortic forces in the ballistocardiogram under rest and exercise conditions.

Authors:  Richard M Wiard; Hyun Jin Kim; C Figueroa; Gregory T A Kovacs; Charles A Taylor; Laurent Giovangrandi
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009
View more
  6 in total

1.  Simplified detection of myocardial ischemia by seismocardiography. Differentiation between causes of altered myocardial function.

Authors:  M Becker; A B Roehl; U Siekmann; A Koch; M de la Fuente; R Roissant; K Radermacher; N Marx; M Hein
Journal:  Herz       Date:  2013-06-23       Impact factor: 1.443

2.  Ballistocardiography--a method worth revisiting.

Authors:  Laurent Giovangrandi; Omer T Inan; Richard M Wiard; Mozziyar Etemadi; Gregory T A Kovacs
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

Review 3.  An Overview of the Sensors for Heart Rate Monitoring Used in Extramural Applications.

Authors:  Alessandra Galli; Roel J H Montree; Shuhao Que; Elisabetta Peri; Rik Vullings
Journal:  Sensors (Basel)       Date:  2022-05-26       Impact factor: 3.847

4.  Flexible capacitive electrodes for minimizing motion artifacts in ambulatory electrocardiograms.

Authors:  Jeong Su Lee; Jeong Heo; Won Kyu Lee; Yong Gyu Lim; Youn Ho Kim; Kwang Suk Park
Journal:  Sensors (Basel)       Date:  2014-08-12       Impact factor: 3.576

5.  Heart Rate Variability Monitoring during Sleep Based on Capacitively Coupled Textile Electrodes on a Bed.

Authors:  Hong Ji Lee; Su Hwan Hwang; Hee Nam Yoon; Won Kyu Lee; Kwang Suk Park
Journal:  Sensors (Basel)       Date:  2015-05-14       Impact factor: 3.576

6.  Motion Artifact Quantification and Sensor Fusion for Unobtrusive Health Monitoring.

Authors:  Christoph Hoog Antink; Florian Schulz; Steffen Leonhardt; Marian Walter
Journal:  Sensors (Basel)       Date:  2017-12-25       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.