Literature DB >> 19147897

Robust ballistocardiogram acquisition for home monitoring.

O T Inan1, M Etemadi, R M Wiard, L Giovangrandi, G T A Kovacs.   

Abstract

The ballistocardiogram (BCG) measures the reaction of the body to cardiac ejection forces, and is an effective, non-invasive means of evaluating cardiovascular function. A simple, robust method is presented for acquiring high-quality, repeatable BCG signals from a modified, commercially available scale. The measured BCG waveforms for all subjects qualitatively matched values in the existing literature and physiologic expectations in terms of timing and IJ amplitude. Additionally, the BCG IJ amplitude was shown to be correlated with diastolic filling time for a subject with premature atrial contractions, demonstrating the sensitivity of the apparatus to beat-by-beat hemodynamic changes. The signal-to-noise ratio (SNR) of the BCG was estimated using two methods, and the average SNR over all subjects was greater than 12 for both estimates. The BCG measurement was shown to be repeatable over 50 recordings taken from the same subject over a three week period. This approach could allow patients at home to monitor trends in cardiovascular health.

Entities:  

Mesh:

Year:  2009        PMID: 19147897     DOI: 10.1088/0967-3334/30/2/005

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  45 in total

1.  Automatic detection of motion artifacts in the ballistocardiogram measured on a modified bathroom scale.

Authors:  Richard M Wiard; Omer T Inan; Brian Argyres; Mozziyar Etemadi; Gregory T A Kovacs; Laurent Giovangrandi
Journal:  Med Biol Eng Comput       Date:  2010-12-09       Impact factor: 2.602

2.  Mitigation of Instrument-Dependent Variability in Ballistocardiogram Morphology: Case Study on Force Plate and Customized Weighing Scale.

Authors:  Yang Yao; Zahra Ghasemi; Md Mobashir Hasan Shandhi; Hazar Ashouri; Lisheng Xu; Ramakrishna Mukkamala; Omer T Inan; Jin-Oh Hahn
Journal:  IEEE J Biomed Health Inform       Date:  2019-02-25       Impact factor: 5.772

3.  Automatic Detection of Seismocardiogram Sensor Misplacement for Robust Pre-Ejection Period Estimation in Unsupervised Settings.

Authors:  Hazar Ashouri; Omer T Inan
Journal:  IEEE Sens J       Date:  2017-05-04       Impact factor: 3.301

4.  A Ballistographic Approach for Continuous and Non-Obtrusive Monitoring of Movement in Neonates.

Authors:  Rohan Joshi; Bart L Bierling; Xi Long; Janna Weijers; Loe Feijs; Carola Van Pul; Peter Andriessen
Journal:  IEEE J Transl Eng Health Med       Date:  2018-10-12       Impact factor: 3.316

5.  Classification of Decompensated Heart Failure From Clinical and Home Ballistocardiography.

Authors:  Varol Burak Aydemir; Supriya Nagesh; Md Mobashir Hasan Shandhi; Joanna Fan; Liviu Klein; Mozziyar Etemadi; James Alex Heller; Omer T Inan; James M Rehg
Journal:  IEEE Trans Biomed Eng       Date:  2019-08-15       Impact factor: 4.538

6.  A novel system identification technique for improved wearable hemodynamics assessment.

Authors:  Andrew D Wiens; Omer T Inan
Journal:  IEEE Trans Biomed Eng       Date:  2015-01-01       Impact factor: 4.538

7.  Ballistocardiogram as Proximal Timing Reference for Pulse Transit Time Measurement: Potential for Cuffless Blood Pressure Monitoring.

Authors:  Chang-Sei Kim; Andrew M Carek; Ramakrishna Mukkamala; Omer T Inan; Jin-Oh Hahn
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-02       Impact factor: 4.538

8.  Performance Analysis of Gyroscope and Accelerometer Sensors for Seismocardiography-Based Wearable Pre-Ejection Period Estimation.

Authors:  Md Mobashir Hasan Shandhi; Beren Semiz; Sinan Hersek; Nazli Goller; Farrokh Ayazi; Omer T Inan
Journal:  IEEE J Biomed Health Inform       Date:  2019-01-28       Impact factor: 5.772

9.  Estimation of central aortic forces in the ballistocardiogram under rest and exercise conditions.

Authors:  Richard M Wiard; Hyun Jin Kim; C Figueroa; Gregory T A Kovacs; Charles A Taylor; Laurent Giovangrandi
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

10.  Simultaneous Monitoring of Ballistocardiogram and Photoplethysmogram Using a Camera.

Authors:  Dangdang Shao; Francis Tsow; Chenbin Liu; Yuting Yang; Nongjian Tao
Journal:  IEEE Trans Biomed Eng       Date:  2016-06-29       Impact factor: 4.538

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.