Literature DB >> 23793836

Simplified detection of myocardial ischemia by seismocardiography. Differentiation between causes of altered myocardial function.

M Becker1, A B Roehl, U Siekmann, A Koch, M de la Fuente, R Roissant, K Radermacher, N Marx, M Hein.   

Abstract

Seismocardiography (SCG) is a noninvasive technique for recording cardiac vibrations. Changes in these waves have been correlated with chronic and acute alterations in myocardial function. This analysis is complex and clinical integration limited. The current study aimed to simplify the utilization of SCG by fast Fourier transformation for a reliable discrimination between different intra- and postoperative causes of hypotension (i.e., myocardial ischemia or hypovolemia). We operated on nine pigs and recorded SCG at baseline, at hypovolemia (occlusion of the inferior vena cava), and at ischemia (occlusion of the right coronary artery). In conclusion, SCG enables detection and differentiation of ischemia and hypovolemia as important causes of altered myocardial function during and after surgery. Thus, this simple and noninvasive diagnostic tool may be used intra- and postoperatively to identify patients at risk.

Entities:  

Mesh:

Year:  2013        PMID: 23793836     DOI: 10.1007/s00059-013-3851-x

Source DB:  PubMed          Journal:  Herz        ISSN: 0340-9937            Impact factor:   1.443


  24 in total

1.  Automatic sleep staging based on ballistocardiographic signals recorded through bed sensors.

Authors:  Matteo Migliorini; Anna M Bianchi; Domenico Nisticò; Juha Kortelainen; Edgar Arce-Santana; Sergio Cerutti; Martin O Mendez
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2010

2.  Novel methods for estimating the ballistocardiogram signal using a simultaneously acquired electrocardiogram.

Authors:  Omer T Inan; Mozziyar Etemadi; Richard M Wiard; Gregory T A Kovacs; Laurent Giovangrandi
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

3.  Short and longer term repeatability of ballistocardiography in a sitting position with EMFi sensor.

Authors:  Jarmo Alametsä; Ari Palomäki; Jari Viik
Journal:  Med Biol Eng Comput       Date:  2011-02-19       Impact factor: 2.602

4.  Three dimensional ballisto- and seismo-cardiography: HIJ wave amplitudes are poorly correlated to maximal systolic force vector.

Authors:  P-F Migeotte; S De Ridder; J Tank; N Pattyn; I Funtova; R Baevsky; X Neyt; G K Prisk
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2012

5.  Multi-channel optical sensor-array for measuring ballistocardiograms and respiratory activity in bed.

Authors:  Christoph Brüser; Anna Kerekes; Stefan Winter; Steffen Leonhardt
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2012

6.  An implantable intracardiac accelerometer for monitoring myocardial contractility. The Multicenter PEA Study Group.

Authors:  A F Rickards; T Bombardini; G Corbucci; G Plicchi
Journal:  Pacing Clin Electrophysiol       Date:  1996-12       Impact factor: 1.976

7.  Sternal acceleration ballistocardiography and arterial pressure wave analysis to determine stroke volume.

Authors:  W P McKay; P H Gregson; B W McKay; J Militzer
Journal:  Clin Invest Med       Date:  1999-02       Impact factor: 0.825

8.  Assessment of magnetic resonance velocity mapping of global ventricular function during dobutamine infusion in coronary artery disease.

Authors:  D J Pennell; D N Firmin; P Burger; G Z Yang; C C Manzara; P J Ell; R H Swanton; J M Walker; S R Underwood; D B Longmore
Journal:  Br Heart J       Date:  1995-08

9.  Diagnostic accuracy of seismocardiography compared with electrocardiography for the anatomic and physiologic diagnosis of coronary artery disease during exercise testing.

Authors:  R A Wilson; V S Bamrah; J Lindsay; M Schwaiger; J Morganroth
Journal:  Am J Cardiol       Date:  1993-03-01       Impact factor: 2.778

10.  Detection of acute myocardial ischemia during percutaneous transluminal coronary angioplasty by endocardial acceleration.

Authors:  Heinz P Theres; Daniel R Kaiser; Shannon D Nelson; Martin Glos; Thomas Leuthold; Gert Baumann; Sameh Sowelam; Todd J Sheldon; Lee Stylos
Journal:  Pacing Clin Electrophysiol       Date:  2004-05       Impact factor: 1.976

View more
  9 in total

1.  Coronary Artery Disease Detected by Low Frequency Heart Sounds.

Authors:  Samuel Emil Schmidt; Lene Helleskov Madsen; John Hansen; Henrik Zimmermann; Henning Kelbæk; Simon Winter; Dorte Hammershøi; Egon Toft; Johannes Jan Struijk; Peter Clemmensen
Journal:  Cardiovasc Eng Technol       Date:  2022-05-11       Impact factor: 2.495

2.  Detecting Aortic Valve-Induced Abnormal Flow with Seismocardiography and Cardiac MRI.

Authors:  Ethan M I Johnson; J Alex Heller; Florencia Garcia Vicente; Roberto Sarnari; Daniel Gordon; Patrick M McCarthy; Alex J Barker; Mozziyar Etemadi; Michael Markl
Journal:  Ann Biomed Eng       Date:  2020-03-16       Impact factor: 3.934

3.  Accelerometer-Based Method for Extracting Respiratory and Cardiac Gating Information for Dual Gating during Nuclear Medicine Imaging.

Authors:  Mojtaba Jafari Tadi; Tero Koivisto; Mikko Pänkäälä; Ari Paasio
Journal:  Int J Biomed Imaging       Date:  2014-07-10

4.  Unified frame of reference improves inter-subject variability of seismocardiograms.

Authors:  Mikko Paukkunen; Petteri Parkkila; Raimo Kettunen; Raimo Sepponen
Journal:  Biomed Eng Online       Date:  2015-02-26       Impact factor: 2.819

5.  Automatic Identification of Systolic Time Intervals in Seismocardiogram.

Authors:  Ghufran Shafiq; Sivanagaraja Tatinati; Wei Tech Ang; Kalyana C Veluvolu
Journal:  Sci Rep       Date:  2016-11-22       Impact factor: 4.379

6.  Gyrocardiography: A New Non-invasive Monitoring Method for the Assessment of Cardiac Mechanics and the Estimation of Hemodynamic Variables.

Authors:  Mojtaba Jafari Tadi; Eero Lehtonen; Antti Saraste; Jarno Tuominen; Juho Koskinen; Mika Teräs; Juhani Airaksinen; Mikko Pänkäälä; Tero Koivisto
Journal:  Sci Rep       Date:  2017-07-28       Impact factor: 4.379

7.  SeisMote: A Multi-Sensor Wireless Platform for Cardiovascular Monitoring in Laboratory, Daily Life, and Telemedicine.

Authors:  Marco Di Rienzo; Giovannibattista Rizzo; Zeynep Melike Işılay; Prospero Lombardi
Journal:  Sensors (Basel)       Date:  2020-01-26       Impact factor: 3.576

8.  Can Seismocardiogram Fiducial Points Be Used for the Routine Estimation of Cardiac Time Intervals in Cardiac Patients?

Authors:  Zeynep Melike Işilay Zeybek; Vittorio Racca; Antonio Pezzano; Monica Tavanelli; Marco Di Rienzo
Journal:  Front Physiol       Date:  2022-03-18       Impact factor: 4.566

9.  Mechanocardiography in the Detection of Acute ST Elevation Myocardial Infarction: The MECHANO-STEMI Study.

Authors:  Tero Koivisto; Olli Lahdenoja; Tero Hurnanen; Tuija Vasankari; Samuli Jaakkola; Tuomas Kiviniemi; K E Juhani Airaksinen
Journal:  Sensors (Basel)       Date:  2022-06-09       Impact factor: 3.847

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.