Literature DB >> 7235054

A new method for long-term monitoring of the ballistocardiogram, heart rate, and respiration.

J Alihanka, K Vaahtoranta, I Saarikivi.   

Abstract

The principle of the static charge-sensitive-bed (SCSB) method is described. The method is simple and inexpensive. From the SCSB recording the ballistocardiogram (BCG) and respiratory movement can be simultaneously recorded by selective filtering of the original signal. The SCSB recording thus enables continuous long-term monitoring of the BCG, heart rate, respiratory rate, respiratory amplitude, and body movements. There are no electrodes or cables connected to the subject. The SCSB-BCG signal was studied by comparing the SCSB method with the conventional ultralow-frequency (ULF) acceleration BCG. The wave forms at rest and the amplitude responses to physical exercise were studied by both methods. Multiple recordings of the BCG, heart rate, respiratory movement, respiratory rate, and body movements after exercise and during sleep using the SCSB method are presented. The SCSB method opens new approaches to long-term studies of the regulation of myocardial performance, heart rate, and respiration. Applications of the SCSB method for clinical sleep studies, patient monitoring and cardiovascular screening examinations are discussed.

Entities:  

Mesh:

Year:  1981        PMID: 7235054     DOI: 10.1152/ajpregu.1981.240.5.R384

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  25 in total

1.  Automatic detection of motion artifacts in the ballistocardiogram measured on a modified bathroom scale.

Authors:  Richard M Wiard; Omer T Inan; Brian Argyres; Mozziyar Etemadi; Gregory T A Kovacs; Laurent Giovangrandi
Journal:  Med Biol Eng Comput       Date:  2010-12-09       Impact factor: 2.602

2.  Unconstrained cardiorespiratory and body movement monitoring system for home care.

Authors:  K Niizeki; I Nishidate; K Uchida; M Kuwahara
Journal:  Med Biol Eng Comput       Date:  2005-11       Impact factor: 2.602

3.  Cardiopulmonary monitoring by textile electrodes without subject-awareness of being monitored.

Authors:  M Ishijima
Journal:  Med Biol Eng Comput       Date:  1997-11       Impact factor: 2.602

4.  New noninvasive piezoelectric transducer for recording of respiration, heart rate and body movements.

Authors:  J Siivola
Journal:  Med Biol Eng Comput       Date:  1989-07       Impact factor: 2.602

5.  A novel system identification technique for improved wearable hemodynamics assessment.

Authors:  Andrew D Wiens; Omer T Inan
Journal:  IEEE Trans Biomed Eng       Date:  2015-01-01       Impact factor: 4.538

6.  Early postnatal treatment with propranolol affects development of brain amines and behavior.

Authors:  L A Hilakivi; T Taira; I Hilakivi; E MacDonald; L Tuomisto; K Hellevuo
Journal:  Psychopharmacology (Berl)       Date:  1988       Impact factor: 4.530

7.  Sleep Parameter Assessment Accuracy of a Consumer Home Sleep Monitoring Ballistocardiograph Beddit Sleep Tracker: A Validation Study.

Authors:  Jarno Tuominen; Karoliina Peltola; Tarja Saaresranta; Katja Valli
Journal:  J Clin Sleep Med       Date:  2019-03-15       Impact factor: 4.062

8.  Validity of sheet-type portable monitoring device for screening obstructive sleep apnea syndrome.

Authors:  Mina Kobayashi; Kazuyoshi Namba; Satoru Tsuiki; Masaki Nakamura; Masamichi Hayashi; Yuuki Mieno; Hiromi Imizu; Shiho Fujita; Atsushi Yoshikawa; Hiroki Sakakibara; Yuichi Inoue
Journal:  Sleep Breath       Date:  2012-06-16       Impact factor: 2.816

9.  CPAP adherence and partial upper airway obstruction during sleep.

Authors:  Ulla Anttalainen; Tarja Saaresranta; Nea Kalleinen; Jenni Aittokallio; Tero Vahlberg; Olli Polo
Journal:  Sleep Breath       Date:  2007-09       Impact factor: 2.816

10.  The effects of transdermal scopolamine on autonomic nervous activity during sleep.

Authors:  J Alihanka; A Lahdenperä; T Kaila
Journal:  Eur J Clin Pharmacol       Date:  1994       Impact factor: 2.953

View more