Literature DB >> 21089174

Evaluation of BD Vacutainer SST™ II Plus tubes for common tumor marker tests by Roche Diagnostics Modular E 170 analyzer.

Zhiyan Li1, Zhenru Feng, Cunling Yan, Rong Yan.   

Abstract

Serum separator tubes were introduced 35 years ago and were widely used in the clinical laboratory in China for routine collection of blood because of providing a closed system that allowed for collection, transport, processing, sampling, and storage of specimens. This type of tubes facilitated rapid separation of serum from cellular constituents of blood and also prevented hemolysis upon prolonged storage. However, there were some limitations associated with gel tubes (i.e., gel and analyte stability). In order to circumvent these problems, BD released a new serum separator tube containing a new gel (BD SST(™) II Plus). We investigated the performance of BD SST(™) II Plus tubes for tumor marker tests using BD Serum Glass tubes as controls. Equivalence between the BD SST(™) II Plus and BD Serum Glass tubes was demonstrated for all analytes at initial time. Also, all analytes remained stable when stored in BD SST(™) II Plus tubes up to 72  hr. Concentration of neuron-specific enolase tended to increase with preservation time up to 72  hr in BD Serum Glass tubes. We conclude that BD SST(™) II Plus was suitable for collection of blood and storage of serum for tumor marker tests.
© 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21089174      PMCID: PMC6647588          DOI: 10.1002/jcla.20422

Source DB:  PubMed          Journal:  J Clin Lab Anal        ISSN: 0887-8013            Impact factor:   2.352


  10 in total

1.  Effect of serum volume and time of exposure to gel barrier tubes on results for progesterone by Roche Diagnostics Elecsys 2010.

Authors:  J D Ferry; S Collins; E Sykes
Journal:  Clin Chem       Date:  1999-09       Impact factor: 8.327

2.  Time-dependent absorption of therapeutic drugs by the gel of the Greiner Vacuette blood collection tube.

Authors:  A Dasgupta; M A Yared; A Wells
Journal:  Ther Drug Monit       Date:  2000-08       Impact factor: 3.681

3.  Potential interferences from blood collection tubes in mass spectrometric analyses of serum polypeptides.

Authors:  Steven K Drake; Raffick A R Bowen; Alan T Remaley; Glen L Hortin
Journal:  Clin Chem       Date:  2004-12       Impact factor: 8.327

4.  Comparison of plastic vs. glass evacuated serum-separator (SST) blood-drawing tubes for common clinical chemistry determinations.

Authors:  B M Hill; R H Laessig; D D Koch; D J Hassemer
Journal:  Clin Chem       Date:  1992-08       Impact factor: 8.327

5.  Assessment of a serum separator device for obtaining serum specimens suitable for clinical analyses.

Authors:  R H Laessig; J O Westgard; R N Carey; D J Hassemer; T H Schwartz; D H Feldbruegge
Journal:  Clin Chem       Date:  1976-02       Impact factor: 8.327

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  Absorption of therapeutic drugs by barrier gels in serum separator blood collection tubes. Volume- and time-dependent reduction in total and free drug concentrations.

Authors:  A Dasgupta; R Dean; S Saldana; G Kinnaman; R W McLawhon
Journal:  Am J Clin Pathol       Date:  1994-04       Impact factor: 2.493

8.  Evaluation of evacuated blood-collection tubes: effects of three types of polymeric separators on therapeutic drug-monitoring specimens.

Authors:  M Landt; C H Smith; G L Hortin
Journal:  Clin Chem       Date:  1993-08       Impact factor: 8.327

9.  Effects of hemolysis and storage condition on neuron-specific enolase (NSE) in cerebrospinal fluid and serum: implications in clinical practice.

Authors:  Laurent Ramont; Henri Thoannes; Ariel Volondat; François Chastang; Marie-Christine Millet; François-Xavier Maquart
Journal:  Clin Chem Lab Med       Date:  2005       Impact factor: 3.694

10.  Interference caused by the contents of serum separator tubes in the Vitros CRP assay.

Authors:  Chia-Yu Chang; Jin-Ying Lu; Tzu-I Chien; Jau-Tsuen Kao; Mei-Chun Lin; Pei-Chun Shih; Shiao-Ni Yan
Journal:  Ann Clin Biochem       Date:  2003-05       Impact factor: 2.057

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.