Evaluation of evacuated blood-collection tubes: effects of three types of polymeric separators on therapeutic drug-monitoring specimens.

M Landt1, C H Smith, G L Hortin.   

Abstract

The potential of three types of separator materials found in conventional blood-collection tubes for interference in therapeutic drug measurements was assessed. None of the separators (based on acrylic, silicone, or polyester polymers) had any significant effect on the concentrations of seven drugs (theophylline, digoxin, phenytoin, phenobarbital, gentamicin, ethanol, and cyclosporine) in blood specimens that were processed and analyzed promptly. Storage of specimens for 24 h resulted in an average 2.4% increase in theophylline values in specimens collected in tubes with the acrylic separator (P = 0.024); an average 8.1% decrease in phenytoin in specimens collected in tubes with the polyester-based separator (P < 0.001); and an average 4.2% decrease in phenobarbital in specimens collected in tubes with the polyester-based separator (P = 0.02). All other drug concentrations were not significantly affected. A small decrease in phenytoin (7.9%; P < 0.01) was seen when the specimen volume in 7-mL tubes containing polyester-based separator was reduced to 1.0 mL; all other drug concentrations were unaffected by partial filling of tubes. Paired blood specimens from pediatric patients, when collected in plain tubes and tubes containing acrylic separator, yielded no significant differences for theophylline, digoxin, tobramycin, phenytoin, or phenobarbital concentrations. The three commercially available separators had only small effects on therapeutic drug concentrations, and a newly developed separator based on an acrylic resin was suitably inert.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8353961

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  3 in total

1.  Evaluation of BD Vacutainer SST™ II Plus tubes for common tumor marker tests by Roche Diagnostics Modular E 170 analyzer.

Authors:  Zhiyan Li; Zhenru Feng; Cunling Yan; Rong Yan
Journal:  J Clin Lab Anal       Date:  2010       Impact factor: 2.352

2.  Comparison of the effect of gel used in two different serum separator tubes for thyroid function tests.

Authors:  Müjgan Ercan; Esra Fırat Oğuz; Emiş Deniz Akbulut; Mustafa Yilmaz; Turan Turhan
Journal:  J Clin Lab Anal       Date:  2018-03-07       Impact factor: 2.352

3.  Blood collection tube-related alterations in analyte concentrations in quality control material and serum specimens.

Authors:  Raffick A R Bowen; Annie Sattayapiwat; Verena Gounden; Alan T Remaley
Journal:  Clin Biochem       Date:  2013-11-14       Impact factor: 3.281

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.