Clinical results of a pilot study on stereovision-guided stereotactic radiotherapy and intensity modulated radiotherapy.

Shidong Li1, Lawrence R Kleinberg, Daniele Rigamonti, Moody D Wharam, Abdul Rashid, Juan Jackson, David Djajaputra, Shenjen He, Tunisia Creasey, Theodore L DeWeese.   

Abstract

Real-time stereovision-guidance has been introduced for efficient and convenient fractionated stereotactic radiotherapy (FSR) and image-guided intensity-modulated radiation therapy (IMRT). This first pilot study is to clinically evaluate its accuracy and precision as well as impact on treatment doses. Sixty-one FSR patients wearing stereotactic masks (SMs) and nine IMRT patients wearing flexible masks (FMs), were accrued. Daily target reposition was initially based-on biplane-radiographs and then adjusted in six degrees of freedom under real-time stereovision guidance. Mean and standard deviation of the head displacements measured the accuracy and precision. Head positions during beam-on times were measured with real-time stereovisions and used for determination of delivered doses. Accuracy ± ± precision in direction with the largest errors shows improvement from 0.4 ± 2.3 mm to 0.0 ± 1.0 mm in the inferior-to-superior direction for patients wearing SM or from 0.8 ± 4.3 mm to 0.4 ± 1.7 mm in the posterior-to-anterior direction for patients wearing FM. The image-guidance increases target volume coverage by >30% for small lesions. Over half of head position errors could be removed from the stereovision-guidance. Importantly, the technique allows us to check head position during beam-on time and makes it possible for having frameless head refixation without tight masks.

Entities:  

Mesh:

Year:  2010        PMID: 21070083      PMCID: PMC3113483          DOI: 10.1177/153303461000900609

Source DB:  PubMed          Journal:  Technol Cancer Res Treat        ISSN: 1533-0338


  38 in total

1.  Quality assurance in stereotactic space. A system test for verifying the accuracy of aim in radiosurgery.

Authors:  A Mack; Heinz Czempiel; Hans-Jürg Kreiner; Gerhard Dürr; Berndt Wowra
Journal:  Med Phys       Date:  2002-04       Impact factor: 4.071

2.  A phantom study on the positioning accuracy of the Novalis Body system.

Authors:  Hui Yan; Fang-Fang Yin; Jae Ho Kim
Journal:  Med Phys       Date:  2003-12       Impact factor: 4.071

3.  An analysis of the accuracy of the CyberKnife: a robotic frameless stereotactic radiosurgical system.

Authors:  Steven D Chang; William Main; David P Martin; Iris C Gibbs; M Peter Heilbrun
Journal:  Neurosurgery       Date:  2003-01       Impact factor: 4.654

4.  Real-time 3D surface-image-guided beam setup in radiotherapy of breast cancer.

Authors:  David Djajaputra; Shidong Li
Journal:  Med Phys       Date:  2005-01       Impact factor: 4.071

5.  The TALON removable head frame system for stereotactic radiosurgery/radiotherapy: measurement of the repositioning accuracy.

Authors:  B J Salter; M Fuss; D G Vollmer; A Sadeghi; C A Bogaev; D A Cheek; T S Herman; J M Hevezi
Journal:  Int J Radiat Oncol Biol Phys       Date:  2001-10-01       Impact factor: 7.038

6.  Image localization for frameless stereotactic radiotherapy.

Authors:  S L Meeks; F J Bova; T H Wagner; J M Buatti; W A Friedman; K D Foote
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-03-15       Impact factor: 7.038

7.  Accuracy of a relocatable stereotactic radiotherapy head frame evaluated by use of a depth helmet.

Authors:  K E Burton; S J Thomas; D Whitney; D S Routsis; R J Benson; N G Burnet
Journal:  Clin Oncol (R Coll Radiol)       Date:  2002-02       Impact factor: 4.126

8.  [Improved patient repositioning accuracy by integrating an additional jaw fixation into a high precision face mask system in stereotactic radiotherapy of the head].

Authors:  Eric Lopatta; Susie-Maria Liesenfeld; Priska Bank; Reinhard Wurm; Robert Günther; Tilo Wiezorek; Thomas G Wendt
Journal:  Strahlenther Onkol       Date:  2003-08       Impact factor: 3.621

Review 9.  Frameless stereotactic radiosurgery with mobile CT, mask immobilization and micro-multileaf collimators.

Authors:  H Takeuchi; M Yoshida; T Kubota; H Ishii; K Sato; Y Handa; H Itoh
Journal:  Minim Invasive Neurosurg       Date:  2003-04

10.  A modified relocatable stereotactic frame for irradiation of eye melanoma: design and evaluation of treatment accuracy.

Authors:  Karin Muller; Peter J C M Nowak; Grégorius P M Luyten; Johannes P Marijnissen; Connie de Pan; Peter Levendag
Journal:  Int J Radiat Oncol Biol Phys       Date:  2004-01-01       Impact factor: 7.038

View more
  1 in total

1.  Initial validation and clinical experience with 3D optical-surface-guided whole breast irradiation of breast cancer.

Authors:  S Li; T DeWeese; B Movsas; Dezhi Liu; Deborah Frassica; Jinkoo Kim; Qing Chen; Eleanor Walker
Journal:  Technol Cancer Res Treat       Date:  2012-02
  1 in total