A phantom study was conducted to investigate inherent positioning accuracy of an image-guided patient positioning system-the Novalis Body system for three-dimensional (3-D) conformal radiotherapy. This positioning system consists of two infrared (IR) cameras and one video camera and two kV x-ray imaging devices. The initial patient setup was guided by the IR camera system and the target localization was accomplished using the kV x-ray imaging system. In this study, the IR marker shift and phantom rotation were simulated and their effects on the positioning accuracy were examined by a Rando phantom. The effects of CT slice thickness and treatment sites on the positioning accuracy were tested. In addition, the internal target shift was simulated and its effect on the positioning accuracy was examined by a water tank. With the application of the Novalis Body system, the positioning error of the planned isocenter was significantly reduced. The experimental results with the simulated IR marker shifts indicated that the positioning errors of the planned isocenter were 0.6 +/- 0.3, 0.5 +/- 0.2, and 0.7 +/- 0.2 mm along the lateral, longitudinal, and vertical axes, respectively. The experimental results with the simulated phantom rotations indicated that the positioning errors of the planned isocenter were 0.6 +/- 0.3, 0.7 +/- 0.2, and 0.5 +/- 0.2 mm along the three axes, respectively. The experimental results with the simulated target shifts indicated that the positioning errors of the planned isocenter were 0.6 +/- 0.3, 0.7 +/- 0.2, and 0.5 +/- 0.2 mm along the three axes, respectively. On average, the positioning accuracy of 1 mm for the planned isocenter was achieved using the Novalis Body system.

Entities:  

Mesh:

Year:  2003        PMID: 14713071     DOI: 10.1118/1.1626122

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  29 in total

Review 1.  A review of image-guided radiotherapy.

Authors:  George T Y Chen; Gregory C Sharp; Shinichiro Mori
Journal:  Radiol Phys Technol       Date:  2008-12-16

2.  Development of a GPU-based multithreaded software application to calculate digitally reconstructed radiographs for radiotherapy.

Authors:  Shinichiro Mori; Masanao Kobayashi; Motoki Kumagai; Shinichi Minohara
Journal:  Radiol Phys Technol       Date:  2008-11-07

3.  Clinical results of a pilot study on stereovision-guided stereotactic radiotherapy and intensity modulated radiotherapy.

Authors:  Shidong Li; Lawrence R Kleinberg; Daniele Rigamonti; Moody D Wharam; Abdul Rashid; Juan Jackson; David Djajaputra; Shenjen He; Tunisia Creasey; Theodore L DeWeese
Journal:  Technol Cancer Res Treat       Date:  2010-12

Review 4.  Radiotherapy for renal cell carcinoma: renaissance of an overlooked approach.

Authors:  Shankar Siva; Gargi Kothari; Alexander Muacevic; Alexander V Louie; Ben J Slotman; Bin S Teh; Simon S Lo
Journal:  Nat Rev Urol       Date:  2017-06-20       Impact factor: 14.432

Review 5.  Radiosurgery for spinal malignant tumors.

Authors:  Berndt Wowra; Alexander Muacevic; Stefan Zausinger; Jörg-Christian Tonn
Journal:  Dtsch Arztebl Int       Date:  2009-02-13       Impact factor: 5.594

6.  An Accurate Recognition of Infrared Retro-Reflective Markers in Surgical Navigation.

Authors:  Han Wu; Qinyong Lin; Rongqian Yang; Yuan Zhou; Lingxiang Zheng; Yueshan Huang; Zhigang Wang; Yonghua Lao; Jinhua Huang
Journal:  J Med Syst       Date:  2019-04-24       Impact factor: 4.460

7.  Accuracy of positional correction for the floor-mounted kV X-ray IGRT system in angled couch positions.

Authors:  Satoshi Koubuchi; Toru Takakura; Mitsuhiro Nakamura; Takashi Mizowaki; Manabu Nakata; Masahiro Hiraoka
Journal:  Radiol Phys Technol       Date:  2014-06-13

8.  Accelerating dynamic magnetic resonance imaging (MRI) for lung tumor tracking based on low-rank decomposition in the spatial-temporal domain: a feasibility study based on simulation and preliminary prospective undersampled MRI.

Authors:  Manoj Sarma; Peng Hu; Stanislas Rapacchi; Daniel Ennis; Albert Thomas; Percy Lee; Patrick Kupelian; Ke Sheng
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-01-09       Impact factor: 7.038

9.  Radiosurgery technology development and use.

Authors:  Sanford L Meeks; Jason Pukala; Naren Ramakrishna; Twyla R Willoughby; Francis J Bova
Journal:  J Radiosurg SBRT       Date:  2011

10.  Semi-robotic 6 degree of freedom positioning for intracranial high precision radiotherapy; first phantom and clinical results.

Authors:  Jürgen Wilbert; Matthias Guckenberger; Bülent Polat; Otto Sauer; Michael Vogele; Michael Flentje; Reinhart A Sweeney
Journal:  Radiat Oncol       Date:  2010-05-26       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.