Literature DB >> 21053003

Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): Evaluation of image noise reduction in 32 patients.

François Pontana1, Julien Pagniez, Thomas Flohr, Jean-Baptiste Faivre, Alain Duhamel, Jacques Remy, Martine Remy-Jardin.   

Abstract

OBJECTIVE: To assess noise reduction achievable with an iterative reconstruction algorithm.
METHODS: 32 consecutive chest CT angiograms were reconstructed with regular filtered back projection (FBP) (Group 1) and an iterative reconstruction technique (IRIS) with 3 (Group 2a) and 5 (Group 2b) iterations.
RESULTS: Objective image noise was significantly reduced in Group 2a and Group 2b compared with FBP (p < 0.0001). There was a significant reduction in the level of subjective image noise in Group 2a compared with Group 1 images (p < 0.003), further reinforced on Group 2b images (Group 2b vs Group 1; p < 0.0001) (Group 2b vs Group 2a; p = 0.0006). The overall image quality scores significantly improved on Group 2a images compared with Group 1 images (p = 0.0081) and on Group 2b images compared with Group 2a images (p < 0.0001). Comparative analysis of individual CT features of mild lung infiltration showed improved conspicuity of ground glass attenuation (p < 0.0001), ill-defined micronodules (p = 0.0351) and emphysematous lesions (p < 0.0001) on Group 2a images, further improved on Group 2b images for ground glass attenuation (p < 0.0001), and emphysematous lesions (p = 0.0087).
CONCLUSION: Compared with regular FBP, iterative reconstructions enable significant reduction of image noise without loss of diagnostic information, thus having the potential to decrease radiation dose during chest CT examinations.

Entities:  

Mesh:

Year:  2010        PMID: 21053003     DOI: 10.1007/s00330-010-1990-5

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  16 in total

1.  Diffuse lung disease: CT of the chest with adaptive statistical iterative reconstruction technique.

Authors:  Priyanka Prakash; Mannudeep K Kalra; Jeanne B Ackman; Subba R Digumarthy; Jiang Hsieh; Synho Do; Jo-Anne O Shepard; Matthew D Gilman
Journal:  Radiology       Date:  2010-07       Impact factor: 11.105

Review 2.  Radiation dose reduction in chest CT: a review.

Authors:  Takeshi Kubo; Pei-Jan Paul Lin; Wolfram Stiller; Masaya Takahashi; Hans-Ulrich Kauczor; Yoshiharu Ohno; Hiroto Hatabu
Journal:  AJR Am J Roentgenol       Date:  2008-02       Impact factor: 3.959

3.  A three-dimensional statistical approach to improved image quality for multislice helical CT.

Authors:  Jean-Baptiste Thibault; Ken D Sauer; Charles A Bouman; Jiang Hsieh
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

Review 4.  Radiation dose in cardiac CT.

Authors:  John R Mayo; Jonathon A Leipsic
Journal:  AJR Am J Roentgenol       Date:  2009-03       Impact factor: 3.959

5.  Dual-source chest CT angiography with high temporal resolution and high pitch modes: evaluation of image quality in 140 patients.

Authors:  Nunzia Tacelli; Martine Remy-Jardin; Thomas Flohr; Jean-Baptiste Faivre; Valérie Delannoy; Alain Duhamel; Jacques Remy
Journal:  Eur Radiol       Date:  2009-11-05       Impact factor: 5.315

Review 6.  Management of suspected acute pulmonary embolism in the era of CT angiography: a statement from the Fleischner Society.

Authors:  Martine Remy-Jardin; Massimo Pistolesi; Lawrence R Goodman; Warren B Gefter; Alexander Gottschalk; John R Mayo; H Dirk Sostman
Journal:  Radiology       Date:  2007-09-11       Impact factor: 11.105

7.  Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: initial experience.

Authors:  Priyanka Prakash; Mannudeep K Kalra; Subba R Digumarthy; Jiang Hsieh; Homer Pien; Sarabjeet Singh; Matthew D Gilman; Jo-Anne O Shepard
Journal:  J Comput Assist Tomogr       Date:  2010-01       Impact factor: 1.826

8.  The 15-Country Collaborative Study of Cancer Risk among Radiation Workers in the Nuclear Industry: estimates of radiation-related cancer risks.

Authors:  E Cardis; M Vrijheid; M Blettner; E Gilbert; M Hakama; C Hill; G Howe; J Kaldor; C R Muirhead; M Schubauer-Berigan; T Yoshimura; F Bermann; G Cowper; J Fix; C Hacker; B Heinmiller; M Marshall; I Thierry-Chef; D Utterback; Y-O Ahn; E Amoros; P Ashmore; A Auvinen; J-M Bae; J Bernar; A Biau; E Combalot; P Deboodt; A Diez Sacristan; M Eklöf; H Engels; G Engholm; G Gulis; R R Habib; K Holan; H Hyvonen; A Kerekes; J Kurtinaitis; H Malker; M Martuzzi; A Mastauskas; A Monnet; M Moser; M S Pearce; D B Richardson; F Rodriguez-Artalejo; A Rogel; H Tardy; M Telle-Lamberton; I Turai; M Usel; K Veress
Journal:  Radiat Res       Date:  2007-04       Impact factor: 2.841

9.  Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults.

Authors:  Aaron Sodickson; Pieter F Baeyens; Katherine P Andriole; Luciano M Prevedello; Richard D Nawfel; Richard Hanson; Ramin Khorasani
Journal:  Radiology       Date:  2009-04       Impact factor: 11.105

10.  Whole-body PET/CT scanning: estimation of radiation dose and cancer risk.

Authors:  Bingsheng Huang; Martin Wai-Ming Law; Pek-Lan Khong
Journal:  Radiology       Date:  2009-02-27       Impact factor: 11.105

View more
  59 in total

1.  Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose.

Authors:  Eun-Ah Park; Whal Lee; Kwang Woo Kim; Kwang Gi Kim; Allmendinger Thomas; Jin Wook Chung; Jae Hyung Park
Journal:  Int J Cardiovasc Imaging       Date:  2011-12-21       Impact factor: 2.357

2.  Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults.

Authors:  Gaurav S Desai; Raul N Uppot; Elaine W Yu; Avinash R Kambadakone; Dushyant V Sahani
Journal:  Eur Radiol       Date:  2012-04-19       Impact factor: 5.315

3.  Low-dose CT of the lung: potential value of iterative reconstructions.

Authors:  Stephan Baumueller; Anna Winklehner; Christoph Karlo; Robert Goetti; Thomas Flohr; Erich W Russi; Thomas Frauenfelder; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2012-06-15       Impact factor: 5.315

4.  Quantifying the potential for dose reduction with visual grading regression.

Authors:  O Smedby; M Fredrikson; J De Geer; L Borgen; M Sandborg
Journal:  Br J Radiol       Date:  2012-06-20       Impact factor: 3.039

5.  Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patients.

Authors:  François Pontana; Alain Duhamel; Julien Pagniez; Thomas Flohr; Jean-Baptiste Faivre; Anne-Lise Hachulla; Jacques Remy; Martine Remy-Jardin
Journal:  Eur Radiol       Date:  2010-11-16       Impact factor: 5.315

6.  Computational and human observer image quality evaluation of low dose, knowledge-based CT iterative reconstruction.

Authors:  Brendan L Eck; Rachid Fahmi; Kevin M Brown; Stanislav Zabic; Nilgoun Raihani; Jun Miao; David L Wilson
Journal:  Med Phys       Date:  2015-10       Impact factor: 4.071

Review 7.  Paediatric cardiac computed tomography: a review of imaging techniques and radiation dose consideration.

Authors:  Carolyn Young; Andrew M Taylor; Catherine M Owens
Journal:  Eur Radiol       Date:  2010-12-28       Impact factor: 5.315

8.  Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations.

Authors:  Angeliki Neroladaki; Diomidis Botsikas; Sana Boudabbous; Christoph D Becker; Xavier Montet
Journal:  Eur Radiol       Date:  2012-08-15       Impact factor: 5.315

9.  Optimization-based image reconstruction with artifact reduction in C-arm CBCT.

Authors:  Dan Xia; David A Langan; Stephen B Solomon; Zheng Zhang; Buxin Chen; Hao Lai; Emil Y Sidky; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2016-10-03       Impact factor: 3.609

10.  Repeated head CT in the neurosurgical intensive care unit: feasibility of sinogram-affirmed iterative reconstruction-based ultra-low-dose CT for surveillance.

Authors:  I Corcuera-Solano; A H Doshi; A Noor; L N Tanenbaum
Journal:  AJNR Am J Neuroradiol       Date:  2014-02-20       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.