Literature DB >> 26119344

Evaluation of the effective dose of cone beam CT and multislice CT for temporomandibular joint examinations at optimized exposure levels.

N Kadesjö1,2, D Benchimol1, B Falahat3, K Näsström1, X-Q Shi1.   

Abstract

OBJECTIVES: To compare the effective dose to patients from temporomandibular joint examinations using a dental CBCT device and a multislice CT (MSCT) device, both before and after dose optimization.
METHODS: A Promax(®) 3D (Planmeca, Helsinki, Finland) dental CBCT and a LightSpeed VCT(®) (GE Healthcare, Little Chalfont, UK) multislice CT were used. Organ doses and effective doses were estimated from thermoluminescent dosemeters at 61 positions inside an anthropomorphic phantom at the exposure settings in clinical use. Optimized exposure protocols were obtained through an optimization study using a dry skull phantom, where four observers rated image quality taken at different exposure levels. The optimal exposure level was obtained when all included criteria were rated as acceptable or better by all observers.
RESULTS: The effective dose from a bilateral examination was 184 µSv for Promax 3D and 113 µSv for LightSpeed VCT before optimization. Post optimization, the bilateral effective dose was 92 µSv for Promax 3D and 124 µSv for LightSpeed VCT.
CONCLUSIONS: At optimized exposure levels, the effective dose from CBCT was comparable to MSCT.

Entities:  

Keywords:  cone beam computed tomography; temporomandibular joint; thermoluminescent dosimetry

Mesh:

Year:  2015        PMID: 26119344      PMCID: PMC4628419          DOI: 10.1259/dmfr.20150041

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  18 in total

1.  Optimization of cone beam CT exposure for pre-surgical evaluation of the implant site.

Authors:  A Dawood; J Brown; V Sauret-Jackson; S Purkayastha
Journal:  Dentomaxillofac Radiol       Date:  2011-12-19       Impact factor: 2.419

2.  Evaluation of subjective image quality in relation to diagnostic task for cone beam computed tomography with different fields of view.

Authors:  Sara Lofthag-Hansen; Anne Thilander-Klang; Kerstin Gröndahl
Journal:  Eur J Radiol       Date:  2010-10-20       Impact factor: 3.528

3.  Effective dose range for dental cone beam computed tomography scanners.

Authors:  Ruben Pauwels; Jilke Beinsberger; Bruno Collaert; Chrysoula Theodorakou; Jessica Rogers; Anne Walker; Lesley Cockmartin; Hilde Bosmans; Reinhilde Jacobs; Ria Bogaerts; Keith Horner
Journal:  Eur J Radiol       Date:  2010-12-31       Impact factor: 3.528

4.  Response functions for computing absorbed dose to skeletal tissues from photon irradiation--an update.

Authors:  Perry B Johnson; Amir A Bahadori; Keith F Eckerman; Choonsik Lee; Wesley E Bolch
Journal:  Phys Med Biol       Date:  2011-03-22       Impact factor: 3.609

Review 5.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

6.  Ultra-high resolution flat-panel volume CT: fundamental principles, design architecture, and system characterization.

Authors:  Rajiv Gupta; Michael Grasruck; Christoph Suess; Soenke H Bartling; Bernhard Schmidt; Karl Stierstorfer; Stefan Popescu; Tom Brady; Thomas Flohr
Journal:  Eur Radiol       Date:  2006-03-10       Impact factor: 5.315

Review 7.  Conebeam CT of the head and neck, part 1: physical principles.

Authors:  A C Miracle; S K Mukherji
Journal:  AJNR Am J Neuroradiol       Date:  2009-05-13       Impact factor: 3.825

8.  ICRP Publication 110. Realistic reference phantoms: an ICRP/ICRU joint effort. A report of adult reference computational phantoms.

Authors:  Hans-Georg Menzel; Christopher Clement; Paul DeLuca
Journal:  Ann ICRP       Date:  2009

9.  Cone-beam computed tomography to detect erosions of the temporomandibular joint: Effect of field of view and voxel size on diagnostic efficacy and effective dose.

Authors:  Zachary T Librizzi; Aditya S Tadinada; Jayasanker V Valiyaparambil; Alan G Lurie; Sanjay M Mallya
Journal:  Am J Orthod Dentofacial Orthop       Date:  2011-07       Impact factor: 2.650

10.  Low-dose dental computed tomography: significant dose reduction without loss of image quality.

Authors:  P Rustemeyer; U Streubühr; J Suttmoeller
Journal:  Acta Radiol       Date:  2004-12       Impact factor: 1.990

View more
  4 in total

1.  Initial evaluation of image performance of a 3-D x-ray system: phantom-based comparison of 3-D tomography with conventional computed tomography.

Authors:  Robyn Melanie Benz; Meritxell Alzamora Garcia; Felix Amsler; Johannes Voigt; Andreas Fieselmann; Anna Lucja Falkowski; Bram Stieltjes; Anna Hirschmann
Journal:  J Med Imaging (Bellingham)       Date:  2018-03-06

2.  Dosimetry of Critical Organs in Maxillofacial Imaging with Cone-beam Computed Tomography.

Authors:  R Ghanbarnezhad Farshi; A Mesbahi; M Johari; Ü Kara; N Gharehaghaji
Journal:  J Biomed Phys Eng       Date:  2019-02-01

3.  Evaluation of a low-dose protocol for cone beam computed tomography of the temporomandibular joint.

Authors:  Durer Iskanderani; Mats Nilsson; Per Alstergren; Xie-Qi Shi; Kristina Hellen-Halme
Journal:  Dentomaxillofac Radiol       Date:  2020-04-09       Impact factor: 2.419

4.  Controversial Aspects of Diagnostics and Therapy of Arthritis of the Temporomandibular Joint in Rheumatoid and Juvenile Idiopathic Arthritis-An Analysis of Evidence- and Consensus-Based Recommendations Based on an Interdisciplinary Guideline Project.

Authors:  Christopher Schmidt; Rudolf Reich; Bernd Koos; Taila Ertel; Marcus Oliver Ahlers; Martin Arbogast; Ima Feurer; Mario Habermann-Krebs; Tim Hilgenfeld; Christian Hirsch; Boris Hügle; Thekla von Kalle; Johannes Kleinheinz; Andreas Kolk; Peter Ottl; Christoph Pautke; Merle Riechmann; Andreas Schön; Linda Skroch; Marcus Teschke; Wolfgang Wuest; Andreas Neff
Journal:  J Clin Med       Date:  2022-03-22       Impact factor: 4.241

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.