Literature DB >> 20924771

Influence of three mechanical bileaflet prosthetic valve designs on the three-dimensional flow field inside a simulated aorta.

Toshinosuke Akutsu1, Akira Matsumoto.   

Abstract

The current design of the bileaflet valve, the leaflets of which open outside first, differs significantly from the natural valve whose leaflets open center first. This difference generates a completely different flow field in the bileaflet valve compared to that in the natural heart valve. In a previous study, it was demonstrated that the valve design greatly affects the aortic flow field as well as the circulatory flow inside sinuses of Valsalva, using saline solution as a working fluid. A limited discussion on the turbulence flow field that could be generated by the valve was provided. In this continuation of that study, therefore, a dynamic PIV study was conducted to analyze the influence of the heart valve design on the aortic flow field, and particularly on the turbulent profile. This study also aimed to determine the influence of the viscosity of the testing fluid. Three bileaflet prostheses-the St. Jude Medical (SJM), the On-X, and the MIRA valves-were tested under pulsatile flow conditions. Flow through the central orifice of the SJM valve was slower than that through the newer designs. The newer designs tend to show strong flow through all orifices. The On-X valve generates simple jet-type flow while the MIRA valve with circumferentially curved leaflets generates a strong but three-dimensionally diffuse flow, resulting in a more complex flow field downstream of the aortic valve with higher turbulence. A 180° orientation that is more popular clinically seems to provide a less diffuse flow than a 90° orientation. The effect of increasing the viscosity was found to be an increase in the flow velocity through the central orifice and a more organized flow field for all of the valves tested.

Entities:  

Mesh:

Year:  2010        PMID: 20924771     DOI: 10.1007/s10047-010-0519-7

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  8 in total

1.  THE ANATOMY OF THE MITRAL VALVE AND ITS ASSOCIATED STRUCTURES.

Authors:  L A DUPLESSIS; P MARCHAND
Journal:  Thorax       Date:  1964-05       Impact factor: 9.139

2.  Surgical correction of aortic insufficiency.

Authors:  C A HUFNAGEL; W P HARVEY; P J RABIL; T F McDERMOTT
Journal:  Surgery       Date:  1954-05       Impact factor: 3.982

3.  Time-resolved particle image velocimetry and laser doppler anemometry study of the turbulent flow field of bileaflet mechanical mitral prostheses.

Authors:  Toshinosuke Akutsu; Takamasa Fukuda
Journal:  J Artif Organs       Date:  2005       Impact factor: 1.731

4.  Two-dimensional dynamic simulation of platelet activation during mechanical heart valve closure.

Authors:  S Krishnan; H S Udaykumar; J S Marshall; K B Chandran
Journal:  Ann Biomed Eng       Date:  2006-09-30       Impact factor: 3.934

5.  Dynamic particle image velocimetry flow analysis of the flow field immediately downstream of bileaflet mechanical mitral prostheses.

Authors:  Toshinosuke Akutsu; Jun Saito
Journal:  J Artif Organs       Date:  2006       Impact factor: 1.731

6.  Dynamic particle image velocimetry study of the aortic flow field of contemporary mechanical bileaflet prostheses.

Authors:  Toshinosuke Akutsu; Jun Saito; Ryota Imai; Tomoyuki Suzuki; Xiu Dong Cao
Journal:  J Artif Organs       Date:  2008-07-06       Impact factor: 1.731

7.  Unsteady fluid dynamics of several mechanical prosthetic heart valves using a two component laser Doppler anemometer system.

Authors:  T Akutsu; V J Modi
Journal:  Artif Organs       Date:  1997-10       Impact factor: 3.094

8.  Shear-induced activation of platelets.

Authors:  J M Ramstack; L Zuckerman; L F Mockros
Journal:  J Biomech       Date:  1979       Impact factor: 2.712

  8 in total
  4 in total

Review 1.  Journal of Artificial Organs 2010: the year in review.

Authors: 
Journal:  J Artif Organs       Date:  2011-03-16       Impact factor: 1.731

2.  Reduction of aberrant aortic haemodynamics following aortic root replacement with a mechanical valved conduit.

Authors:  Eric J Keller; S Chris Malaisrie; Jane Kruse; Patrick M McCarthy; James C Carr; Michael Markl; Alex J Barker; Jeremy D Collins
Journal:  Interact Cardiovasc Thorac Surg       Date:  2016-05-30

3.  Integrated strategy for in vitro characterization of a bileaflet mechanical aortic valve.

Authors:  Francesca Maria Susin; Stefania Espa; Riccardo Toninato; Stefania Fortini; Giorgio Querzoli
Journal:  Biomed Eng Online       Date:  2017-02-16       Impact factor: 2.819

4.  On-X versus St Jude Medical Regent mechanical aortic valve prostheses: early haemodynamics.

Authors:  Robert Xu; Mohammad Rahnavardi; Bradley Pitman; Masoumeh Shirazi; Robert Stuklis; James Edwards; Michael Worthington
Journal:  Open Heart       Date:  2017-02-23
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.