Dynamic particle image velocimetry flow analysis of the flow field immediately downstream of bileaflet mechanical mitral prostheses.

Toshinosuke Akutsu1, Jun Saito.   

Abstract

New dynamic particle image velocimetry (PIV) technology was applied to the study of the flow field associated with prosthetic heart valves. Four bileaflet prostheses, the St. Jude Medical (SJM) valve, the On-X valve with straight leaflets, the Jyros (JR) valve, and the Edwards MIRA (MIRA) valve with curved leaflets, were tested in the mitral position under pulsatile flow conditions to find the effect of the leaflet shape and overall valve design on the flow field, particularly in terms of the turbulent stress distribution, which may influence hemolysis, platelet activation, and thrombus formation. Comparison of the time-resolved flow fields associated with the opening, accelerating, peak, and closing phases of the diastolic flow revealed the effects of the leaflet shape and overall valve design on the flow field. Anatomically and antianatomically oriented bileaflet valves were also compared in the mitral position to study the effects of the orientation on the downstream flow field. The experimental program used a dynamic PIV system utilizing a high-speed, high-resolution video camera to map the true time-resolved velocity field inside the simulated ventricle. Based on the experimental data, the following general conclusions can be made. High-resolution dynamic PIV can capture true chronological changes in the velocity and turbulence fields. In the vertical measuring plane that passes the centers of both the aortic and mitral valves (A-A section), bileaflet valves show clear and simple circulatory flow patterns when the valve is installed in the antianatomical orientation. The SJM, the On-X, and the MIRA valves maintain a relatively high velocity through the central orifice. The curved leaflets of the JR valve generate higher velocities with a divergent flow during the accelerating and peak flow phases when the valve is installed in the anatomical orientation. In the velocity field directly below the mitral valve and normal to the previous measuring plane (B-B section), where characteristic differences in valve design on the three-dimensional flow should be visible, the symmetrical divergent nature of the flow generated by the two inclined half-disks installed in the antianatomical orientation was evident. The SJM valve, with a central downward flow near the valve, is contrasted with the JR valve, which has a peripherally strong downward circulation with higher turbulent stresses. The On-X valve has a strong central downward flow attributable to its large opening angle and flared inlet shape. The MIRA valve also has a relatively strong downward central flow. The MIRA valve, however, diverts the flow three-dimensionally due to its peripherally curved leaflets.

Entities:  

Mesh:

Year:  2006        PMID: 16998702     DOI: 10.1007/s10047-006-0340-5

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  7 in total

1.  Three-dimensional flow analysis of a mechanical bileaflet mitral prosthesis.

Authors:  Toshinosuke Akutsu; Takashi Masuda
Journal:  J Artif Organs       Date:  2003       Impact factor: 1.731

2.  THE ANATOMY OF THE MITRAL VALVE AND ITS ASSOCIATED STRUCTURES.

Authors:  L A DUPLESSIS; P MARCHAND
Journal:  Thorax       Date:  1964-05       Impact factor: 9.139

3.  Surgical correction of aortic insufficiency.

Authors:  C A HUFNAGEL; W P HARVEY; P J RABIL; T F McDERMOTT
Journal:  Surgery       Date:  1954-05       Impact factor: 3.982

4.  Time-resolved particle image velocimetry and laser doppler anemometry study of the turbulent flow field of bileaflet mechanical mitral prostheses.

Authors:  Toshinosuke Akutsu; Takamasa Fukuda
Journal:  J Artif Organs       Date:  2005       Impact factor: 1.731

5.  Unsteady fluid dynamics of several mechanical prosthetic heart valves using a two component laser Doppler anemometer system.

Authors:  T Akutsu; V J Modi
Journal:  Artif Organs       Date:  1997-10       Impact factor: 3.094

6.  An artificial arterial system for pumping hearts.

Authors:  N Westerhof; G Elzinga; P Sipkema
Journal:  J Appl Physiol       Date:  1971-11       Impact factor: 3.531

7.  A 5 1/2 year experience with the St. Jude Medical cardiac valve prosthesis. Early and late results of 737 valve replacements in 671 patients.

Authors:  E M Baudet; C C Oca; X F Roques; M N Laborde; A S Hafez; M A Collot; I M Ghidoni
Journal:  J Thorac Cardiovasc Surg       Date:  1985-07       Impact factor: 5.209

  7 in total
  6 in total

1.  Flow visualization for different port angles of a pulsatile ventricular assist device.

Authors:  Eiki Akagawa; Hwansung Lee; Eisuke Tatsumi; Akihiko Homma; Tomonori Tsukiya; Yoshiyuki Taenaka
Journal:  J Artif Organs       Date:  2011-10-30       Impact factor: 1.731

2.  Influence of three mechanical bileaflet prosthetic valve designs on the three-dimensional flow field inside a simulated aorta.

Authors:  Toshinosuke Akutsu; Akira Matsumoto
Journal:  J Artif Organs       Date:  2010-10-07       Impact factor: 1.731

3.  Journal of Artificial Organs 2006: the year in review.

Authors:  Y Sawa; T Horiuchi; A Kishida; T Masuzawa; M Nishimura; E Tatsumi; Y Tomizawa; H Watanabe
Journal:  J Artif Organs       Date:  2007-06-20       Impact factor: 1.731

4.  Correlation between ventricular flow field and valve closing sound of mechanical mitral prostheses.

Authors:  Toshinosuke Akutsu; Ryota Imai; Jun Saito; Tomoyuki Suzuki
Journal:  J Artif Organs       Date:  2008-07-06       Impact factor: 1.731

5.  Effects of leaflet geometry on the flow field in three bileaflet valves when installed in a pneumatic ventricular assist device.

Authors:  Hwansung Lee; Yoshiaki Ikeuchi; Eiki Akagawa; Eisuke Tatsumi; Yoshiyuki Taenaka; Takao Yamamoto
Journal:  J Artif Organs       Date:  2009-06-18       Impact factor: 1.731

6.  Effects of Bileaflet Mechanical Mitral Valve Rotational Orientation on Left Ventricular Flow Conditions.

Authors:  John C Westerdale; Ronald Adrian; Kyle Squires; Hari Chaliki; Marek Belohlavek
Journal:  Open Cardiovasc Med J       Date:  2015-06-26
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.