Time-resolved particle image velocimetry and laser doppler anemometry study of the turbulent flow field of bileaflet mechanical mitral prostheses.

Toshinosuke Akutsu1, Takamasa Fukuda.   

Abstract

Dynamic particle image velocimetry (PIV) was applied to the study of the flow field associated with prosthetic heart valves. The results were compared with those of laser Doppler anemometry (LDA). Anatomically and antianatomically oriented Jyros (JR) and St. Jude Medical (SJM) valves were compared in the mitral position to study the effects of valve design on the downstream flow field. The experimental program used a dynamic PIV system utilizing high-speed, high-resolution video to map the true time-resolved velocity field inside the simulated ventricle. This system was complemented by a study using the more traditional LDA system for comparison. Based on the experimental data, the following general conclusions can be made. High-resolution dynamic PIV can capture true chronological changes in the velocity and turbulence fields. It also produces very detailed velocity and turbulence information comparable to the LDA results. In the vertical measuring plane that passes both the center of the aortic and mitral valves (A-A section), the two valves (the SJM and the JR) show distinct circulatory flow patterns when the valve is installed in the antianatomical orientation. Small differences in valve design can generate noticeable differences, particularly during the accelerating flow phase. The SJM valve maintains a relatively high velocity through the central orifice; the curved leaflets of the JR valve generate higher velocities with a divergent flow during the accelerating and peak flow phases. In the velocity field directly below the mitral valve and normal to the previous measuring plane (B-B section), where characteristic differences in valve design will be visible, symmetrical twin circulations were observed because of the divergent nature of the flow generated by the two inclined half-disks installed in the antianatomical orientation. The SJM valve, with a central downward flow near the valve, is contrasted with the JR valve, which has a peripheral downward circulation with higher, turbulent stresses.

Entities:  

Mesh:

Year:  2005        PMID: 16235034     DOI: 10.1007/s10047-005-0298-8

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  7 in total

1.  Three-dimensional flow analysis of a mechanical bileaflet mitral prosthesis.

Authors:  Toshinosuke Akutsu; Takashi Masuda
Journal:  J Artif Organs       Date:  2003       Impact factor: 1.731

2.  THE ANATOMY OF THE MITRAL VALVE AND ITS ASSOCIATED STRUCTURES.

Authors:  L A DUPLESSIS; P MARCHAND
Journal:  Thorax       Date:  1964-05       Impact factor: 9.139

3.  Surgical correction of aortic insufficiency.

Authors:  C A HUFNAGEL; W P HARVEY; P J RABIL; T F McDERMOTT
Journal:  Surgery       Date:  1954-05       Impact factor: 3.982

4.  Unsteady fluid dynamics of several mechanical prosthetic heart valves using a two component laser Doppler anemometer system.

Authors:  T Akutsu; V J Modi
Journal:  Artif Organs       Date:  1997-10       Impact factor: 3.094

5.  Turbulent stress measurements downstream of six mechanical aortic valves in a pulsatile flow model.

Authors:  J M Hasenkam; H Nygaard; M Giersiepen; H Reul; H Stødkilde-Jørgensen
Journal:  J Biomech       Date:  1988       Impact factor: 2.712

6.  An artificial arterial system for pumping hearts.

Authors:  N Westerhof; G Elzinga; P Sipkema
Journal:  J Appl Physiol       Date:  1971-11       Impact factor: 3.531

7.  A 5 1/2 year experience with the St. Jude Medical cardiac valve prosthesis. Early and late results of 737 valve replacements in 671 patients.

Authors:  E M Baudet; C C Oca; X F Roques; M N Laborde; A S Hafez; M A Collot; I M Ghidoni
Journal:  J Thorac Cardiovasc Surg       Date:  1985-07       Impact factor: 5.209

  7 in total
  4 in total

1.  Influence of three mechanical bileaflet prosthetic valve designs on the three-dimensional flow field inside a simulated aorta.

Authors:  Toshinosuke Akutsu; Akira Matsumoto
Journal:  J Artif Organs       Date:  2010-10-07       Impact factor: 1.731

2.  Dynamic particle image velocimetry flow analysis of the flow field immediately downstream of bileaflet mechanical mitral prostheses.

Authors:  Toshinosuke Akutsu; Jun Saito
Journal:  J Artif Organs       Date:  2006       Impact factor: 1.731

3.  Correlation between ventricular flow field and valve closing sound of mechanical mitral prostheses.

Authors:  Toshinosuke Akutsu; Ryota Imai; Jun Saito; Tomoyuki Suzuki
Journal:  J Artif Organs       Date:  2008-07-06       Impact factor: 1.731

4.  Dynamic particle image velocimetry study of the aortic flow field of contemporary mechanical bileaflet prostheses.

Authors:  Toshinosuke Akutsu; Jun Saito; Ryota Imai; Tomoyuki Suzuki; Xiu Dong Cao
Journal:  J Artif Organs       Date:  2008-07-06       Impact factor: 1.731

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.