Literature DB >> 20862476

Dose levels at coronary CT angiography--a comparison of Dual Energy-, Dual Source- and 16-slice CT.

J Matthias Kerl1, Ralf W Bauer, Tobias B Maurer, Rene Aschenbach, Huedayi Korkusuz, Thomas Lehnert, Simon Deseive, Hanns Ackermann, Thomas J Vogl.   

Abstract

PURPOSE: To compare the dose estimates and image quality of Dual Energy CT (DECT), Dual Source CT (DSCT) and 16-slice CT for coronary CT angiography (cCTA).
METHODS: Sixty-eight patients were examined with 16 - slice MDCT (group 1), 68 patients with DSCT (group 2) and 68 patients using DSCT in dual energy mode (DECT group 3). CT dose index volume, dose length product, effective dose, signal-to-noise, and contrast-to-noise ratio were compared. Subjective image quality was rated by two observers, blinded to technique.
RESULTS: The mean estimated radiation dose of all patients investigated on a 16 - slice MDCT was 12 ± 3.59 mSv, for DSCT in single energy 9.8 ± 4.77 mSv and for DECT 4.54 ± 1.87 mSv. Dose for CTA was significantly lower in group 3 compared to group 1 and 2. The image noise was significantly lower in Group 2 in comparison to group 1 and group 3. There was no significant difference in diagnostic image quality comparing DECT and DSCT.
CONCLUSION: cCTA shows better dose levels at both DECT and DSCT compared to 16-slice CT. Further, DECT delivers significantly less dose than regular DSCT or single source single energy cCTA while maintaining diagnostic image quality.

Entities:  

Mesh:

Year:  2010        PMID: 20862476     DOI: 10.1007/s00330-010-1954-9

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  41 in total

1.  Technique factors and image quality as functions of patient weight at abdominal CT.

Authors:  W Huda; E M Scalzetti; G Levin
Journal:  Radiology       Date:  2000-11       Impact factor: 11.105

2.  A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association.

Authors:  W G Austen; J E Edwards; R L Frye; G G Gensini; V L Gott; L S Griffith; D C McGoon; M L Murphy; B B Roe
Journal:  Circulation       Date:  1975-04       Impact factor: 29.690

Review 3.  Computed tomography coronary angiography.

Authors:  Stephan Achenbach
Journal:  J Am Coll Cardiol       Date:  2006-11-01       Impact factor: 24.094

4.  Image quality and reconstruction intervals of dual-source CT coronary angiography: recommendations for ECG-pulsing windowing.

Authors:  Sebastian Leschka; Hans Scheffel; Lotus Desbiolles; Andre Plass; Oliver Gaemperli; Ines Valenta; Lars Husmann; Thomas G Flohr; Michele Genoni; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  Invest Radiol       Date:  2007-08       Impact factor: 6.016

5.  Cardiac spiral dual-source CT with high pitch: a feasibility study.

Authors:  Dirk Ertel; Michael M Lell; Frank Harig; Thomas Flohr; Bernhard Schmidt; Willi A Kalender
Journal:  Eur Radiol       Date:  2009-06-30       Impact factor: 5.315

6.  16-MDCT angiography in living kidney donors at various tube potentials: impact on image quality and radiation dose.

Authors:  Dushyant V Sahani; Sanjeeva P Kalva; Peter F Hahn; Sanjay Saini
Journal:  AJR Am J Roentgenol       Date:  2007-01       Impact factor: 3.959

7.  Low-dose CT coronary angiography for the prediction of myocardial ischaemia.

Authors:  Paul Stolzmann; Olivio F Donati; Hans Scheffel; Naim Azemaj; Stephan Baumueller; André Plass; Sebastian Kozerke; Sebastian Leschka; Jürg Grünenfelder; Peter Boesiger; Borut Marincek; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2009-08-06       Impact factor: 5.315

8.  Radiation dose exposure of computed tomography coronary angiography: comparison of dual-source, 16-slice and 64-slice CT.

Authors:  J Rixe; G Conradi; A Rolf; A Schmermund; A Magedanz; D Erkapic; A Deetjen; C W Hamm; T Dill
Journal:  Heart       Date:  2009-05-28       Impact factor: 5.994

9.  Radiation dose of cardiac dual-source CT: the effect of tailoring the protocol to patient-specific parameters.

Authors:  Hatem Alkadhi; Paul Stolzmann; Hans Scheffel; Lotus Desbiolles; Stephan Baumüller; André Plass; Michele Genoni; Borut Marincek; Sebastian Leschka
Journal:  Eur J Radiol       Date:  2008-10-30       Impact factor: 3.528

10.  Image quality in a low radiation exposure protocol for retrospectively ECG-gated coronary CT angiography.

Authors:  Tobias Pflederer; Larissa Rudofsky; Dieter Ropers; Sven Bachmann; Mohamed Marwan; Werner G Daniel; Stephan Achenbach
Journal:  AJR Am J Roentgenol       Date:  2009-04       Impact factor: 3.959

View more
  12 in total

Review 1.  Recent advances in medical imaging: anatomical and clinical applications.

Authors:  Bruno Grignon; Laurence Mainard; Matthieu Delion; Claude Hodez; Guillaume Oldrini
Journal:  Surg Radiol Anat       Date:  2012-05-29       Impact factor: 1.246

2.  Dose levels and image quality of second-generation 128-slice dual-source coronary CT angiography in clinical routine.

Authors:  Julian L Wichmann; Xiaohan Hu; Alexander Engler; J Matthias Kerl; Martin Beeres; Claudia Frellesen; Wolfgang Luboldt; Thomas J Vogl; Ralf W Bauer; Thomas Lehnert
Journal:  Radiol Med       Date:  2015-05-16       Impact factor: 3.469

Review 3.  New Applications of Cardiac Computed Tomography: Dual-Energy, Spectral, and Molecular CT Imaging.

Authors:  Ibrahim Danad; Zahi A Fayad; Martin J Willemink; James K Min
Journal:  JACC Cardiovasc Imaging       Date:  2015-06

4.  Iterative reconstruction techniques for computed tomography Part 1: technical principles.

Authors:  Martin J Willemink; Pim A de Jong; Tim Leiner; Linda M de Heer; Rutger A J Nievelstein; Ricardo P J Budde; Arnold M R Schilham
Journal:  Eur Radiol       Date:  2013-01-12       Impact factor: 5.315

5.  Radiation dose considerations by intra-individual Monte Carlo simulations in dual source spiral coronary computed tomography angiography with electrocardiogram-triggered tube current modulation and adaptive pitch.

Authors:  Matthias S May; Paul Deak; Axel Kuettner; Michael M Lell; Wolfgang Wuest; Michael Scharf; Andrea K Keller; Lothar Häberle; Stephan Achenbach; Martin Seltmann; Michael Uder; Willi A Kalender
Journal:  Eur Radiol       Date:  2011-10-09       Impact factor: 5.315

Review 6.  Dual-energy computed tomography (DECT) in emergency radiology: basic principles, techniques, and limitations.

Authors:  Shima Aran; Khalid W Shaqdan; Hani H Abujudeh
Journal:  Emerg Radiol       Date:  2014-03-28

7.  Use of dual-energy computed tomography to measure skeletal-wide marrow composition and cancellous bone mineral density.

Authors:  Luke Arentsen; Karen E Hansen; Masashi Yagi; Yutaka Takahashi; Ryan Shanley; Angela McArthur; Patrick Bolan; Taiki Magome; Douglas Yee; Jerry Froelich; Susanta K Hui
Journal:  J Bone Miner Metab       Date:  2016-12-09       Impact factor: 2.626

8.  Dual-energy computed tomography for the assessment of early treatment effects of regorafenib in a preclinical tumor model: comparison with dynamic contrast-enhanced CT and conventional contrast-enhanced single-energy CT.

Authors:  Gesine Knobloch; Gregor Jost; Alexander Huppertz; Bernd Hamm; Hubertus Pietsch
Journal:  Eur Radiol       Date:  2014-05-29       Impact factor: 5.315

9.  The use of adaptive statistical iterative reconstruction (ASiR) technique in evaluation of patients with cervical spine trauma: impact on radiation dose reduction and image quality.

Authors:  Satya N Patro; Santanu Chakraborty; Adnan Sheikh
Journal:  Br J Radiol       Date:  2016-02-17       Impact factor: 3.039

Review 10.  Dual-energy computed tomography for detection of coronary artery disease.

Authors:  Ibrahim Danad; Bríain Ó Hartaigh; James K Min
Journal:  Expert Rev Cardiovasc Ther       Date:  2015-11-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.