Literature DB >> 29851353

Comparison of the accuracy of full head cone beam CT images obtained using a large field of view and stitched images.

Mehmet Ozgur Ozemre1, Ayse Gulsahi1.   

Abstract

OBJECTIVE: : The aim of this study was to investigate the accuracy of the new stitching feature of the Morita 3D Accuitomo device by comparing it with the I-CAT device and real measurements.
METHODS: : Eight dry skulls were used in this study. The full scan mode of an I-CAT device and the new stitching feature of the Morita 3D Accuitomo device were used to obtain full head cone beam CT (CBCT) images, and the linear distances between the selected anatomical sites were measured by two observers. The real distances were measured directly on the skulls using digital calipers. Statistical analyses were performed using the intraclass correlation coefficient and Bland-Altman Limits of Agreement.
RESULTS: : High or perfect agreement was detected between the CBCT images and real measurements. The Bland-Altman Limits of Agreement analysis revealed that the stitched coronal and sagittal images of the Morita might differ by >1.54-1.67 or <0.01 mm from the real measurements.
CONCLUSIONS: : The stitched images of the Morita CBCT device showed perfect agreement with both real measurements and the images of an I-CAT full head scan. After the evaluation of the radiation doses received from stitching sectional images, this device may be used to obtain full head images.

Mesh:

Year:  2018        PMID: 29851353      PMCID: PMC6196062          DOI: 10.1259/dmfr.20170454

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  27 in total

Review 1.  Maxillofacial cone beam computed tomography: essence, elements and steps to interpretation.

Authors:  William C Scarfe; Z Li; W Aboelmaaty; S A Scott; A G Farman
Journal:  Aust Dent J       Date:  2012-03       Impact factor: 2.291

2.  Accuracy and validity of stitching sectional cone beam computed tomographic images.

Authors:  Moon-Key Kim; Sang-Hoon Kang; Eun-Ha Lee; Sang-Hwy Lee; Wonse Park
Journal:  J Craniofac Surg       Date:  2012-07       Impact factor: 1.046

3.  Reduction of the negative influence of patient motion on quality of CBCT scan.

Authors:  Tomáš Hanzelka; René Foltán; Edita Horká; Jiří Sedý
Journal:  Med Hypotheses       Date:  2010-08-30       Impact factor: 1.538

4.  Dimensional stability in composite cone beam computed tomography.

Authors:  S Kopp; P Ottl
Journal:  Dentomaxillofac Radiol       Date:  2010-12       Impact factor: 2.419

5.  Clinical applications of cone-beam computed tomography in dental practice.

Authors:  William C Scarfe; Allan G Farman; Predag Sukovic
Journal:  J Can Dent Assoc       Date:  2006-02       Impact factor: 1.316

Review 6.  Cone-beam computed tomography of the maxillofacial region--an update.

Authors:  Chung How Kau; Marko Bozic; Jeryl English; Robert Lee; Harry Bussa; Randy K Ellis
Journal:  Int J Med Robot       Date:  2009-12       Impact factor: 2.547

7.  Effect of changing the head position on accuracy of transverse measurements of the maxillofacial region made on cone beam computed tomography and conventional posterior-anterior cephalograms.

Authors:  Abbas Shokri; Amirfarhang Miresmaeili; Nasrin Farhadian; Sepideh Falah-Kooshki; Payam Amini; Najmeh Mollaie
Journal:  Dentomaxillofac Radiol       Date:  2017-04-12       Impact factor: 2.419

8.  Cone beam CT image artefacts related to head motion simulated by a robot skull: visual characteristics and impact on image quality.

Authors:  R Spin-Neto; J Mudrak; L H Matzen; J Christensen; E Gotfredsen; A Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2012-07-27       Impact factor: 2.419

9.  Accuracy of three-dimensional measurements obtained from cone beam computed tomography surface-rendered images for cephalometric analysis: influence of patient scanning position.

Authors:  Bassam Hassan; Paul van der Stelt; Gerard Sanderink
Journal:  Eur J Orthod       Date:  2008-12-23       Impact factor: 3.075

10.  Linear accuracy and reliability of cone beam CT derived 3-dimensional images constructed using an orthodontic volumetric rendering program.

Authors:  Danielle R Periago; William C Scarfe; Mazyar Moshiri; James P Scheetz; Anibal M Silveira; Allan G Farman
Journal:  Angle Orthod       Date:  2008-05       Impact factor: 2.079

View more
  1 in total

1.  Quantitative assessment of variation in CBCT image technical parameters related to CBCT detector lateral-offset position.

Authors:  Gustavo Machado Santaella; Pedro Luiz Rosalen; Polyane Mazucatto Queiroz; Francisco Haiter-Neto; Ann Wenzel; Rubens Spin-Neto
Journal:  Dentomaxillofac Radiol       Date:  2019-09-06       Impact factor: 2.419

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.