Literature DB >> 20831992

Sizing for endovascular aneurysm repair: clinical evaluation of a new automated three-dimensional software.

Adrien Kaladji1, Antoine Lucas, Gaëlle Kervio, Pascal Haigron, Alain Cardon.   

Abstract

BACKGROUND: To assess the reproducibility and accuracy of the sizing procedure before aortic endograft implantation using new sizing automated software as compared with standard radiological procedures.
METHODS: On the basis of original spiral-computed tomography images, the sizing of 32 patients with abdominal aortic aneurysm treated by endovascular aneurysm repair (EVAR) was retrospectively compared. The first sizing was performed by a radiologist using a standard workstation (General electrics) and software (Advanced vessel analysis). The second was performed twice by two surgeons using a personal computer with automatic three-dimensional sizing software (Endosize; Therenva, Rennes, France). All diameters and lengths required before EVAR were measured (17 items). Moreover, 13 qualitative criteria regarding EVAR feasibility, including neck length, were compared. Intra- and interobserver variability with Endosize, as well as the variability between the two measurement methods were analyzed using the intraclass correlation coefficient (ICC) and Bland and Altman's method. Qualitative variables were analyzed using Fischer's exact test and kappa coefficient.
RESULTS: Intraobserver variability with Endosize proved to be efficient. None of the ICCs were lower than 0.9, and more than 90% of the absolute differences between two measurements were less than 2 mm. Interobserver variability with Endosize was assessed in a similar manner. Measurement variability of vessel diameters was less marked than that of vessel lengths. This trend was observed for all datasets. Comparison of the two measurement methods demonstrated a good correlation (minimum ICC = 0.697; maximum ICC = 0.974), although less so than that observed using Endosize. Mean time consumption using Endosize was 13.1 ± 4.53 minutes (range: 7.2-32.7). Analysis of the alarm sets demonstrated a high agreement between observers (kappa coefficient = 0.81).
CONCLUSIONS: Sizing using the Endosize software is as reliable as conventional radiological procedures. Sizing by surgeons using an automated, user-friendly, and mobile tool appears to be reproducible.
Copyright © 2010 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20831992      PMCID: PMC3001481          DOI: 10.1016/j.avsg.2010.03.018

Source DB:  PubMed          Journal:  Ann Vasc Surg        ISSN: 0890-5096            Impact factor:   1.466


  15 in total

1.  Accuracy of three-dimensional simulation in the sizing of aortic endoluminal devices.

Authors:  Ihab Aziz; Jason Lee; James T Lee; Carlos E Donayre; Irwin Walot; George Kopchok; S Mirahashemi; H Esmailzadeh; Rodney A White
Journal:  Ann Vasc Surg       Date:  2003-03-06       Impact factor: 1.466

2.  Accuracy of computer-aided measurements in endovascular stent-graft planning: an experimental study with two phantoms.

Authors:  Juha-Matti Isokangas; Rami Hietala; Jukka Perälä; Osmo Tervonen
Journal:  Invest Radiol       Date:  2003-03       Impact factor: 6.016

3.  Two-dimensional versus three-dimensional CT scan for aortic measurement.

Authors:  Ellen D Dillavou; David G Buck; Satish C Muluk; Michel S Makaroun
Journal:  J Endovasc Ther       Date:  2003-06       Impact factor: 3.487

4.  Abdominal aortic aneurysms: virtual imaging and analysis through a remote web server.

Authors:  Emanuele Neri; Irene Bargellini; Michael Rieger; Andrea Giachetti; Claudio Vignali; Massimiliano Tuveri; Werner Jaschke; Carlo Bartolozzi
Journal:  Eur Radiol       Date:  2004-10-16       Impact factor: 5.315

5.  Can preoperative spiral CT scans alone determine the feasibility of endovascular AAA repair? A comparison to angiographic measurements.

Authors:  C K Shin; W Rodino; J D Kirwin; W Wisselink; F M Abruzzo; T F Panetta
Journal:  J Endovasc Ther       Date:  2000-06       Impact factor: 3.487

6.  Intra- and interobserver variability in the measurements of abdominal aortic and common iliac artery diameter with computed tomography. The Tromsø study.

Authors:  K Singh; B K Jacobsen; S Solberg; K H Bønaa; S Kumar; R Bajic; E Arnesen
Journal:  Eur J Vasc Endovasc Surg       Date:  2003-05       Impact factor: 7.069

7.  Is three-dimensional computed tomography reconstruction justified before endovascular aortic aneurysm repair?

Authors:  L Richard Sprouse; George H Meier; F Noel Parent; Richard J DeMasi; Gordon K Stokes; Christopher J LeSar; Michael J Marcinczyk; Bernardo Mendoza
Journal:  J Vasc Surg       Date:  2004-09       Impact factor: 4.268

8.  Variability of maximal aortic aneurysm diameter measurements on CT scan: significance and methods to minimize.

Authors:  Neal S Cayne; Frank J Veith; Evan C Lipsitz; Takao Ohki; Manish Mehta; Nick Gargiulo; William D Suggs; Alla Rozenblit; Zina Ricci; Carlos H Timaran
Journal:  J Vasc Surg       Date:  2004-04       Impact factor: 4.268

9.  Assessment of automatic vessel tracking techniques in preoperative planning of transluminal aortic stent graft implantation.

Authors:  Daniel T Boll; Jonathan S Lewin; Jeffrey L Duerk; Dava Smith; Krishna Subramanyan; Elmar M Merkle
Journal:  J Comput Assist Tomogr       Date:  2004 Mar-Apr       Impact factor: 1.826

10.  Decreased use of iliac extensions and reduced graft junctions with software-assisted centerline measurements in selection of endograft components for endovascular aneurysm repair.

Authors:  Omaida C Velazquez; Edward Y Woo; Jeffrey P Carpenter; Michael A Golden; Clyde F Barker; Ronald M Fairman
Journal:  J Vasc Surg       Date:  2004-08       Impact factor: 4.268

View more
  9 in total

Review 1.  Computer-aided surgery: concepts and applications in vascular surgery.

Authors:  Adrien Kaladji; Antoine Lucas; Alain Cardon; Pascal Haigron
Journal:  Perspect Vasc Surg Endovasc Ther       Date:  2012-04-18

2.  A versatile intensity-based 3D/2D rigid registration compatible with mobile C-arm for endovascular treatment of abdominal aortic aneurysm.

Authors:  A Duménil; A Kaladji; M Castro; C Göksu; A Lucas; P Haigron
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-05-26       Impact factor: 2.924

3.  Generic thrombus segmentation from pre- and post-operative CTA.

Authors:  Florent Lalys; Vincent Yan; Adrien Kaladji; Antoine Lucas; Simon Esneault
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-04-28       Impact factor: 2.924

4.  Validation of a Whole Heart Segmentation from Computed Tomography Imaging Using a Deep-Learning Approach.

Authors:  Sam Sharobeem; Hervé Le Breton; Florent Lalys; Mathieu Lederlin; Clément Lagorce; Marc Bedossa; Dominique Boulmier; Guillaume Leurent; Pascal Haigron; Vincent Auffret
Journal:  J Cardiovasc Transl Res       Date:  2021-08-26       Impact factor: 3.216

5.  Deep Learning to Automatically Segment and Analyze Abdominal Aortic Aneurysm from Computed Tomography Angiography.

Authors:  Francesca Brutti; Alice Fantazzini; Alice Finotello; Lucas Omar Müller; Ferdinando Auricchio; Bianca Pane; Giovanni Spinella; Michele Conti
Journal:  Cardiovasc Eng Technol       Date:  2022-01-08       Impact factor: 2.305

6.  The imaging assessment and specific endograft design for the endovascular repair of ascending aortic dissection.

Authors:  Yepeng Zhang; Hanfei Tang; JianPing Zhou; Zhao Liu; Changjian Liu; Tong Qiao; Min Zhou
Journal:  Clin Interv Aging       Date:  2016-07-14       Impact factor: 4.458

7.  Endograft Sizing for Endovascular Aortic Repair and Incidence of Endoleak Type 1A.

Authors:  Ruben V C Buijs; Clark J Zeebregts; Tineke P Willems; Tryfon Vainas; Ignace F J Tielliu
Journal:  PLoS One       Date:  2016-06-30       Impact factor: 3.240

8.  Measuring of Abdominal Aortic Aneurysm with Three-Dimensional Computed Tomography Reconstruction before Endovascular Aortic Aneurysm Repair.

Authors:  Yoona Chung; Jin Hyun Joh; Ho-Chul Park
Journal:  Vasc Specialist Int       Date:  2017-03-31

9.  Factors affecting the occurrence of proximal endoleak after endovascular abdominal aortic repair for abdominal aneurysms.

Authors:  Daniela Mazzaccaro; Girolomina Mazzeo; Gianmarco Zuccon; Alfredo Modafferi; Giovanni Malacrida; Paolo C Righini; Massimiliano M Marrocco-Trischitta; Giovanni Nano
Journal:  J Int Med Res       Date:  2020-11       Impact factor: 1.671

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.