PURPOSE: To examine if 3-dimensional (3D) reconstructions of computed tomographic (CT) data, by imaging perpendicular to blood flow, can improve aortic diameter measurement accuracy over axial (2D) CT.
METHODS: Two independent, blinded observers used electronic calipers to measure the minor axis and the line perpendicular to it on 40 2.5-mm 2D CT scans from 31 patients. A circular electronic tool was used to estimate diameters on 3D reconstructions from the same 40 scans. Measurements of the aortic neck were obtained 5 mm below the renal arteries and the widest slice of the aneurysm was used to measure sac diameter. Only the minor axis was measured at the iliac arteries immediately above the left (LI) and right (RI) iliac bifurcations. Datasets were compared with an intraclass correlation coefficient (ICC), Bland and Altman variation assessments, and absolute differences.
RESULTS: ICC between 2D and 3D scans demonstrated high correlation with 2D minor axis measurements (neck=0.9282, sac=0.8956, RI=0.8755, LI=0.7381). 3D to 2D major axis correlation was lower (neck=0.6388, sac=0.8995). Variation between 3D and 2D minor axis measurements was low (0.51-mm average variation from the mean for the minor axis and 1.30-mm variation for the major axis). Average absolute difference between 3D and 2D diameters was 1.01 mm (minor axis) versus 2.61 mm (major axis). Interobserver correlation was highest for sac measurements both in 2D minor axis (ICC=0.8990) and 3D (ICC=0.9518).
CONCLUSIONS: Minor axis measurements on axial CT scan can substitute for diameters obtained from 3D reconstructions in most clinical situations.

Entities:  

Mesh:

Year:  2003        PMID: 12932165     DOI: 10.1177/152660280301000319

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  4 in total

1.  Sizing for endovascular aneurysm repair: clinical evaluation of a new automated three-dimensional software.

Authors:  Adrien Kaladji; Antoine Lucas; Gaëlle Kervio; Pascal Haigron; Alain Cardon
Journal:  Ann Vasc Surg       Date:  2010-10       Impact factor: 1.466

2.  On growth measurements of abdominal aortic aneurysms using maximally inscribed spheres.

Authors:  H Gharahi; B A Zambrano; C Lim; J Choi; W Lee; S Baek
Journal:  Med Eng Phys       Date:  2015-05-23       Impact factor: 2.242

3.  Quantitative Micro-CT Analysis of Aortopathy in a Mouse Model of β-aminopropionitrile-induced Aortic Aneurysm and Dissection.

Authors:  Brittany O Aicher; Subhradip Mukhopadhyay; Xin Lu; Selen C Muratoglu; Dudley K Strickland; Areck A Ucuzian
Journal:  J Vis Exp       Date:  2018-07-16       Impact factor: 1.355

Review 4.  Imaging for surveillance and operative management for endovascular aortic aneurysm repairs.

Authors:  Christopher Lau; Dmitriy N Feldman; Leonard N Girardi; Luke K Kim
Journal:  J Thorac Dis       Date:  2017-04       Impact factor: 2.895

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.