Literature DB >> 12616351

Accuracy of three-dimensional simulation in the sizing of aortic endoluminal devices.

Ihab Aziz1, Jason Lee, James T Lee, Carlos E Donayre, Irwin Walot, George Kopchok, S Mirahashemi, H Esmailzadeh, Rodney A White.   

Abstract

The purpose of this study is to examine the accuracy of a 3D simulation generated by inclusion of various intensity-selected portions of spiral CT data into a proprietary software program (Preview, Medical Media Systems, MMS) in preoperative and postoperative assessment of the anatomical features of abdominal aortic aneurysm (AAA). The accuracy of this software was measured against two other modalities-intravascular ultrasound (IVUS) and axial CT scan-using the IVUS as the reference. Eighty-five patients were included; 43 underwent AAA endovascular exclusion with Talent devices, and 42 with Aneurx devices. Measurement of proximal neck diameter was performed using IVUS, Preview software, and axial CT scan with manual calipers. Measurement of the AAA maximum diameter was performed using Preview software and axial CT scan; 253 measurements in the 85 patients were included. These measurements were compared by means of both linear regression and Bland-Altman agreement analysis. Our results showed that the 95% confidence interval between the Preview software and mean IVUS measurement of proximal AAA neck (3.1 and 2.5) is narrow enough for the software to be used in sizing AAA. This would be especially important for having the properly sized devices available preoperatively. The Preview software tended to be more accurate than CT scans although it was not statistically significant.

Entities:  

Mesh:

Year:  2003        PMID: 12616351     DOI: 10.1007/s10016-001-0398-8

Source DB:  PubMed          Journal:  Ann Vasc Surg        ISSN: 0890-5096            Impact factor:   1.466


  4 in total

1.  Sizing for endovascular aneurysm repair: clinical evaluation of a new automated three-dimensional software.

Authors:  Adrien Kaladji; Antoine Lucas; Gaëlle Kervio; Pascal Haigron; Alain Cardon
Journal:  Ann Vasc Surg       Date:  2010-10       Impact factor: 1.466

2.  Abdominal aortic aneurysms: virtual imaging and analysis through a remote web server.

Authors:  Emanuele Neri; Irene Bargellini; Michael Rieger; Andrea Giachetti; Claudio Vignali; Massimiliano Tuveri; Werner Jaschke; Carlo Bartolozzi
Journal:  Eur Radiol       Date:  2004-10-16       Impact factor: 5.315

3.  Morphometric analysis of anatomic variables affecting endovascular stent design in patients undergoing elective and emergency repair of endovascular abdominal aortic aneurysm.

Authors:  Michael Kilian; Wilfred Dang; Claudio S Cinà
Journal:  Can J Surg       Date:  2010-02       Impact factor: 2.089

4.  Measuring of Abdominal Aortic Aneurysm with Three-Dimensional Computed Tomography Reconstruction before Endovascular Aortic Aneurysm Repair.

Authors:  Yoona Chung; Jin Hyun Joh; Ho-Chul Park
Journal:  Vasc Specialist Int       Date:  2017-03-31
  4 in total