Effects of inversion and saturation times on relationships between contrast agent concentrations and signal intensities of T1-weighted magnetic resonance images.

Mahmood Nazarpoor1.   

Abstract

The present study was an attempt to investigate the effect of variation of inversion time (T (I)) and saturation time (T (S)) on the linear relationship between contrast agent concentration and signal intensity (SI) on Turbo Fast Low Angle Shot (TurboFLASH) T (1)-weighted images in MRI. For this purpose, inversion recovery (IR) and saturation recovery (SR) sequences (Center out Phase-Encoding acquisition) were used. A phantom was designed to hold 25 vials which contained either different (between 0 and 19.77 mmol/L) or constant (1.20 mmol/L) concentrations of contrast agent. The vials of constant concentration were used for the measurement of coil non-uniformity, which was normalized to give a correction factor. The vials of different concentrations were used to measure the SI by using different sequences and different T (I) and T (S) values. To calculate the corrected SI for different concentrations, we multiplied the SI of each vial by its correction factor. The relationships between the corrected SI and the concentration [were evaluated], where the threshold of (R (2) = 0.95 and 0.99) was maintained. This study shows that different sequences and different T (I) and T (S) values can have an effect on the correlation between the SI and concentration. Regardless of the values of T (I), T (S), and the different IR and SR sequences chosen, the linear relationship between the SI and concentration was about twice that previously reported (i.e., 0.8 mmol/L, R (2) = 0.95).

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20821085     DOI: 10.1007/s12194-010-0087-9

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  14 in total

1.  Contrast-reduced imaging of tissue concentration and arterial level (CRITICAL) for assessment of cerebral hemodynamics in acute stroke by magnetic resonance.

Authors:  A R Moody; A Martel; A Kenton; S Allder; M A Horsfield; G Delay; P Morgan
Journal:  Invest Radiol       Date:  2000-07       Impact factor: 6.016

2.  Cerebral hemodynamics and cerebral blood volume: MR assessment using gadolinium contrast agents and T1-weighted Turbo-FLASH imaging.

Authors:  B L Dean; C Lee; J E Kirsch; V M Runge; R M Dempsey; L C Pettigrew
Journal:  AJNR Am J Neuroradiol       Date:  1992 Jan-Feb       Impact factor: 3.825

3.  Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths.

Authors:  Martin Rohrer; Hans Bauer; Jan Mintorovitch; Martin Requardt; Hanns-Joachim Weinmann
Journal:  Invest Radiol       Date:  2005-11       Impact factor: 6.016

4.  Sources of intensity nonuniformity in spin echo images at 1.5 T.

Authors:  A Simmons; P S Tofts; G J Barker; S R Arridge
Journal:  Magn Reson Med       Date:  1994-07       Impact factor: 4.668

Review 5.  Contrast agents for cerebral perfusion MR imaging.

Authors:  E C Unger; K Ugurbil; R E Latchaw
Journal:  J Magn Reson Imaging       Date:  1994 May-Jun       Impact factor: 4.813

6.  Quantification of myocardial perfusion with FAST sequence and Gd bolus in patients with normal cardiac function.

Authors:  J P Vallée; F Lazeyras; L Kasuboski; P Chatelain; N Howarth; A Righetti; D Didier
Journal:  J Magn Reson Imaging       Date:  1999-02       Impact factor: 4.813

7.  Influence of bolus volume and dose of gadolinium chelate for first-pass myocardial perfusion MR imaging studies.

Authors:  E Canet; P Douek; M Janier; K Bendid; J Amaya; P Millet; D Revel
Journal:  J Magn Reson Imaging       Date:  1995 Jul-Aug       Impact factor: 4.813

8.  Quantification of gadolinium-DTPA concentrations for different inversion times using an IR-turbo flash pulse sequence: a study on optimizing multislice perfusion imaging.

Authors:  T Fritz-Hansen; E Rostrup; P B Ring; H B Larsson
Journal:  Magn Reson Imaging       Date:  1998-10       Impact factor: 2.546

9.  Does gadolinium-diethylene triamine pentaacetic acid enhanced MRI of kidney represent tissue concentration of contrast media in the kidney? In vivo and in vitro study.

Authors:  M Takeda; Y Katayama; T Tsutsui; T Komeyama; T Mizusawa
Journal:  Magn Reson Imaging       Date:  1994       Impact factor: 2.546

10.  Equilibrium signal intensity mapping, an MRI method for fast mapping of longitudinal relaxation rates and for image enhancement.

Authors:  Pál Surányi; Pál Kiss; Balazs Ruzsics; Brigitta C Brott; Tamás Simor; Gabriel A Elgavish
Journal:  Magn Reson Imaging       Date:  2006-11-21       Impact factor: 2.546

View more
  8 in total

1.  Effect of phase-encoding scheme on the relationship between contrast agent concentration and signal intensity on inversion recovery turbo fast low-angle shot T1-weighted images.

Authors:  Mahmood Nazarpoor
Journal:  Radiol Phys Technol       Date:  2014-02-06

2.  Effect of concentration of contrast agent on the inflow effect for measuring absolute perfusion by use of inversion recovery T₁-weighted TurboFLASH images.

Authors:  Mahmood Nazarpoor
Journal:  Radiol Phys Technol       Date:  2011-11-24

3.  Clinical application of pharmacokinetic analysis as a biomarker of solitary pulmonary nodules: dynamic contrast-enhanced MR imaging.

Authors:  Hatsuho Mamata; Junichi Tokuda; Ritu R Gill; Robert F Padera; Robert E Lenkinski; David J Sugarbaker; James P Butler; Hiroto Hatabu
Journal:  Magn Reson Med       Date:  2012-01-09       Impact factor: 4.668

4.  Evaluation of Maximum and Minimum Signal Intensity and the Linear Relationship between Concentration and Signal Intensity in Saturation Recovery T1-weighted Images by use of a Turbo Fast Low-Angle Shot Sequence.

Authors:  Nazarpoor M
Journal:  J Biomed Phys Eng       Date:  2020-08-01

5.  The effect of inversion times on the minimum signal intensity of the contrast agent concentration using inversion recovery t1-weighted fast imaging sequence.

Authors:  Mahmood Nazarpoor
Journal:  Med J Islam Repub Iran       Date:  2014-11-11

6.  Effect of Flip Angle on the Correlation Between Signal Intensity and Different Concentrations of Iron Oxide Nanoparticles Using T1-Weighted Turbo-FLASH Inversion Recovery Sequence.

Authors:  Nahideh Gharehaghaji; Mahmood Nazarpoor; Hodaiseh Saharkhiz
Journal:  Iran J Radiol       Date:  2015-04-22       Impact factor: 0.212

7.  Effect of iron oxide nanoparticles coating type on the relationship between nanoparticles concentration and signal intensity in inversion recovery T1-weighted MRI.

Authors:  Nahideh Gharehaghaji; Mahmood Nazarpoor; Hodaiseh Saharkhiz
Journal:  Med J Islam Repub Iran       Date:  2015-05-06

8.  Comparison of maximum signal intensity of contrast agent on t1-weighted images using spin echo, fast spin echo and inversion recovery sequences.

Authors:  Mahmood Nazarpoor; Masoud Poureisa; Mohammad Hossein Daghighi
Journal:  Iran J Radiol       Date:  2012-12-27       Impact factor: 0.212

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.