Literature DB >> 9814771

Quantification of gadolinium-DTPA concentrations for different inversion times using an IR-turbo flash pulse sequence: a study on optimizing multislice perfusion imaging.

T Fritz-Hansen1, E Rostrup, P B Ring, H B Larsson.   

Abstract

The purpose of this study was to optimize an inversion-recovery (IR) turbo fast low-angle shot (FLASH) for multislice imaging by evaluating the accuracy of calculated the relaxation-rate (R1) for different inversion times (TI). This is important for tracer kinetic modeling because it requires a system responding linearly to input. R1 are linearly related to changes in the concentration of gadolinium (Gd)-diethylenetriaminepentaacetic acid (DTPA), and R1 is a parameter that can be derived from the magnetic resonance (MR) signal. The accuracy of calculated R1 using an IR turbo fast low-angle shot was evaluated in phantoms and for increasing TIs using spectroscopically measured R1 values as reference. Signal curves, obtained in vivo after a bolus injection of Gd-DTPA, were used in an analytical computer program to study the effect of different TI-values on accurate calculation of R1. Results show that TIeff should be <200 ms to measure the bolus-passage of Gd-DTPA in blood accurately, whereas the myocardial response can be measured correctly for TIeff < 870 ms at 1.5 T. The initial slope of the myocardial signal enhancement curve becomes steeper for larger TI values, whereas the calculated R1 curves were similar, indicating that these curves, rather than signal curves, are more suitable even for qualitative perfusion evaluation. It is concluded that the results can be incorporated in a multislice IR turbo fast low-angle shot using the first slice (with a short TI) for assessment of both the arterial input function and the tissue response and the second slice in another position for assessment of the tissue response alone.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9814771     DOI: 10.1016/s0730-725x(98)00103-9

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  9 in total

1.  Effects of inversion and saturation times on relationships between contrast agent concentrations and signal intensities of T1-weighted magnetic resonance images.

Authors:  Mahmood Nazarpoor
Journal:  Radiol Phys Technol       Date:  2010-02-27

2.  Determination of infarct size in ex vivo swine hearts by multidetector computed tomography using gadolinium as contrast medium.

Authors:  Akos Varga-Szemes; Balazs Ruzsics; Robert Kirschner; Satinder P Singh; Pal Kiss; Brigitta C Brott; Tamas Simor; Ada Elgavish; Gabriel A Elgavish
Journal:  Invest Radiol       Date:  2012-05       Impact factor: 6.016

3.  Effect of phase-encoding scheme on the relationship between contrast agent concentration and signal intensity on inversion recovery turbo fast low-angle shot T1-weighted images.

Authors:  Mahmood Nazarpoor
Journal:  Radiol Phys Technol       Date:  2014-02-06

4.  Evaluation of Maximum and Minimum Signal Intensity and the Linear Relationship between Concentration and Signal Intensity in Saturation Recovery T1-weighted Images by use of a Turbo Fast Low-Angle Shot Sequence.

Authors:  Nazarpoor M
Journal:  J Biomed Phys Eng       Date:  2020-08-01

5.  Combined T2* and T1 measurements for improved perfusion and permeability studies in high field using dynamic contrast enhancement.

Authors:  Cedric de Bazelaire; Neil M Rofsky; Guillaume Duhamel; Jingbo Zhang; M Dror Michaelson; Daniel George; David C Alsop
Journal:  Eur Radiol       Date:  2006-04-01       Impact factor: 5.315

6.  A simple, reproducible method for monitoring the treatment of tumours using dynamic contrast-enhanced MR imaging.

Authors:  B Morgan; J F Utting; A Higginson; A L Thomas; W P Steward; M A Horsfield
Journal:  Br J Cancer       Date:  2006-05-22       Impact factor: 7.640

7.  Measurement of myocardial blood flow by cardiovascular magnetic resonance perfusion: comparison of distributed parameter and Fermi models with single and dual bolus.

Authors:  Giorgos Papanastasiou; Michelle C Williams; Lucy E Kershaw; Marc R Dweck; Shirjel Alam; Saeed Mirsadraee; Martin Connell; Calum Gray; Tom MacGillivray; David E Newby; Scott Ik Semple
Journal:  J Cardiovasc Magn Reson       Date:  2015-02-17       Impact factor: 5.364

Review 8.  MnDPDP: Contrast Agent for Imaging and Protection of Viable Tissue.

Authors:  Per Jynge; Arne M Skjold; Ursula Falkmer; Rolf G G Andersson; John G Seland; Morten Bruvold; Viggo Blomlie; Willy Eidsaunet; Jan O G Karlsson
Journal:  Contrast Media Mol Imaging       Date:  2020-09-04       Impact factor: 3.161

9.  Advances in Myocardial Perfusion MR Imaging: Physiological Implications, the Importance of Quantitative Analysis, and Impact on Patient Care in Coronary Artery Disease.

Authors:  Hajime Sakuma; Masaki Ishida
Journal:  Magn Reson Med Sci       Date:  2021-06-09       Impact factor: 2.760

  9 in total