Effect of concentration of contrast agent on the inflow effect for measuring absolute perfusion by use of inversion recovery T₁-weighted TurboFLASH images.

Mahmood Nazarpoor1.   

Abstract

Previous studies have shown that the organ blood flow (OBF) calculated from the T₁-weighted MRI technique was lower than expected. The inflow correction was one of the main corrections for measuring the absolute OBF. Our aim in this study was to investigate the influence of the contrast agent concentration on inflow effect on signal intensity (SI) and to find the gradient of different flow rates at different concentrations by use of inversion recovery T₁-weighted turbo fast low angle shot (TurboFLASH) MRI images. We performed these studies at six different concentrations of gadolinium-diethylenetriamine-pantaacetic acid (Gd-DTPA) to find the inflow effect on the SI. A flow phantom made of Perspex was designed that produced four different flow rates at the same time. The non-uniformity of the clinical head and neck coil was measured and applied to the SI for measuring the corrected SI. The corrected SI was measured at different flow rates and concentrations. The results indicated that an increase in the flow rate and in the concentration of the contrast agent was associated with an increase in the gradient of the flow rate. The results also indicated that the inflow correction could be ignored when the concentration was low for measurement of the absolute OBF. At high concentrations, the inflow effect should be considered in calculations of the absolute OBF.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22113425     DOI: 10.1007/s12194-011-0140-3

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  12 in total

1.  Absolute renal blood flow quantification by dynamic MRI and Gd-DTPA.

Authors:  J P Vallée; F Lazeyras; H G Khan; F Terrier
Journal:  Eur Radiol       Date:  2000       Impact factor: 5.315

2.  Contrast-reduced imaging of tissue concentration and arterial level (CRITICAL) for assessment of cerebral hemodynamics in acute stroke by magnetic resonance.

Authors:  A R Moody; A Martel; A Kenton; S Allder; M A Horsfield; G Delay; P Morgan
Journal:  Invest Radiol       Date:  2000-07       Impact factor: 6.016

3.  Inflow effect correction in fast gradient-echo perfusion imaging.

Authors:  Marko K Ivancevic; Ivan Zimine; Xavier Montet; Jean-Noel Hyacinthe; François Lazeyras; David Foxall; Jean-Paul Vallée
Journal:  Magn Reson Med       Date:  2003-11       Impact factor: 4.668

4.  Effects of inversion and saturation times on relationships between contrast agent concentrations and signal intensities of T1-weighted magnetic resonance images.

Authors:  Mahmood Nazarpoor
Journal:  Radiol Phys Technol       Date:  2010-02-27

5.  Evaluation of flow measurement from the first pass bolus T1 weighted images using inversion recovery sequence.

Authors:  M Nazarpoor
Journal:  Br J Radiol       Date:  2010-10-19       Impact factor: 3.039

6.  Cerebral hemodynamics and cerebral blood volume: MR assessment using gadolinium contrast agents and T1-weighted Turbo-FLASH imaging.

Authors:  B L Dean; C Lee; J E Kirsch; V M Runge; R M Dempsey; L C Pettigrew
Journal:  AJNR Am J Neuroradiol       Date:  1992 Jan-Feb       Impact factor: 3.825

7.  Image non-uniformity in magnetic resonance imaging: its magnitude and methods for its correction.

Authors:  B R Condon; J Patterson; D Wyper; A Jenkins; D M Hadley
Journal:  Br J Radiol       Date:  1987-01       Impact factor: 3.039

8.  Sources of intensity nonuniformity in spin echo images at 1.5 T.

Authors:  A Simmons; P S Tofts; G J Barker; S R Arridge
Journal:  Magn Reson Med       Date:  1994-07       Impact factor: 4.668

9.  Noninvasive measurement of blood flow and extraction fraction.

Authors:  A M Peters; R D Gunasekera; B L Henderson; J Brown; J P Lavender; M De Souza; J M Ash; D L Gilday
Journal:  Nucl Med Commun       Date:  1987-10       Impact factor: 1.690

10.  Comparison of the added value of contrast-enhanced 3D fluid-attenuated inversion recovery and magnetization-prepared rapid acquisition of gradient echo sequences in relation to conventional postcontrast T1-weighted images for the evaluation of leptomeningeal diseases at 3T.

Authors:  H Fukuoka; T Hirai; T Okuda; Y Shigematsu; A Sasao; E Kimura; T Hirano; S Yano; R Murakami; Y Yamashita
Journal:  AJNR Am J Neuroradiol       Date:  2009-12-24       Impact factor: 3.825

View more
  5 in total

1.  Evaluation of Maximum and Minimum Signal Intensity and the Linear Relationship between Concentration and Signal Intensity in Saturation Recovery T1-weighted Images by use of a Turbo Fast Low-Angle Shot Sequence.

Authors:  Nazarpoor M
Journal:  J Biomed Phys Eng       Date:  2020-08-01

2.  The effect of inversion times on the minimum signal intensity of the contrast agent concentration using inversion recovery t1-weighted fast imaging sequence.

Authors:  Mahmood Nazarpoor
Journal:  Med J Islam Repub Iran       Date:  2014-11-11

3.  Effect of iron oxide nanoparticles coating type on the relationship between nanoparticles concentration and signal intensity in inversion recovery T1-weighted MRI.

Authors:  Nahideh Gharehaghaji; Mahmood Nazarpoor; Hodaiseh Saharkhiz
Journal:  Med J Islam Repub Iran       Date:  2015-05-06

4.  Comparison of maximum signal intensity of contrast agent on t1-weighted images using spin echo, fast spin echo and inversion recovery sequences.

Authors:  Mahmood Nazarpoor; Masoud Poureisa; Mohammad Hossein Daghighi
Journal:  Iran J Radiol       Date:  2012-12-27       Impact factor: 0.212

5.  The Effect of Inversion Time on the Relationship Between Iron Oxide Nanoparticles Concentration and Signal Intensity in T1-Weighted MR Images.

Authors:  Hodaiseh Saharkhiz; Nahideh Gharehaghaji; Mahmood Nazarpoor; Asghar Mesbahi; Masoud Pourissa
Journal:  Iran J Radiol       Date:  2014-05-15       Impact factor: 0.212

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.