Literature DB >> 8007771

Does gadolinium-diethylene triamine pentaacetic acid enhanced MRI of kidney represent tissue concentration of contrast media in the kidney? In vivo and in vitro study.

M Takeda1, Y Katayama, T Tsutsui, T Komeyama, T Mizusawa.   

Abstract

Although Gadolinium-diethylene triamine pentaacetic acid (Gd-DTPA) has been used as a contrast material in magnetic resonance imaging (MRI), it is known that contrast enhancement effect is not uniform if the concentration of Gd-DTPA increases beyond some levels. In this study, to evaluate the proper pulse sequences for dynamic MRI in the human kidney, the concentration of Gd-DTPA was quantitatively measured by inductively coupled plasma (ICP) emission spectrometry in human biological samples after administration of Gd-DTPA. The signal intensity of MRI in the solutions of several concentrations of Gd-DTPA was measured. The results were that in using a low magnetic field apparatus, signal intensity linearly correlated with the concentration of Gd-DTPA between 0 and 2.0 mumol/g under saturation recovery sequences (flip angle = 60 degrees or 90 degrees). Using a high magnetic field apparatus, signal intensity linearly correlated with the concentration of Gd-DTPA between 0 and 2.0 or 3.0 mumol/g under spin-echo or gradient-echo sequences. Gd-DTPA concentration of the renal cortex ranged from 0.132 to 0.152 mumol/g tissue at 5 min after IV injection of Gd-DTPA 0.05 mmol/kg body weight in six patients with adrenal tumor or renal cell cancer, and one patient with both urinary bladder cancer and prostatic cancer. Six of the patients showed normal renal function and the other had renal insufficiency (GFR = 25 ml/min/1.48 m2).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8007771     DOI: 10.1016/0730-725x(94)92535-6

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  5 in total

1.  Effects of inversion and saturation times on relationships between contrast agent concentrations and signal intensities of T1-weighted magnetic resonance images.

Authors:  Mahmood Nazarpoor
Journal:  Radiol Phys Technol       Date:  2010-02-27

2.  Evaluation of glomerular function in individual kidneys using dynamic magnetic resonance imaging.

Authors:  Y Fukuda; H Watanabe; T Tomita; H Katayama; T Miyano; K Yabuta
Journal:  Pediatr Radiol       Date:  1996

3.  Effect of phase-encoding scheme on the relationship between contrast agent concentration and signal intensity on inversion recovery turbo fast low-angle shot T1-weighted images.

Authors:  Mahmood Nazarpoor
Journal:  Radiol Phys Technol       Date:  2014-02-06

4.  Intra-arterial delivery of AAV vectors to the mouse brain after mannitol mediated blood brain barrier disruption.

Authors:  Conor P Foley; David G Rubin; Alejandro Santillan; Dolan Sondhi; Jonathan P Dyke; Ronald G Crystal; Y Pierre Gobin; Douglas J Ballon
Journal:  J Control Release       Date:  2014-09-28       Impact factor: 9.776

5.  Evaluation of Maximum and Minimum Signal Intensity and the Linear Relationship between Concentration and Signal Intensity in Saturation Recovery T1-weighted Images by use of a Turbo Fast Low-Angle Shot Sequence.

Authors:  Nazarpoor M
Journal:  J Biomed Phys Eng       Date:  2020-08-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.