Literature DB >> 24500244

Effect of phase-encoding scheme on the relationship between contrast agent concentration and signal intensity on inversion recovery turbo fast low-angle shot T1-weighted images.

Mahmood Nazarpoor1.   

Abstract

Previous studies have shown that the image parameters such as the repetition time and inversion time (TI) and image sequences can have an effect on the maximum linearity between signal intensity (SI) and concentration. Our aim in this study was to investigate the effect of a phase-encoding scheme (linear phase-encoding and center out phase-encoding) at different TIs on the maximum linear relationship between contrast agent concentration and SI using inversion recovery TurboFLASH (turbo fast low angle shot) T1-weighted images in MRI. A phantom was designed to hold 25 vials which contained either different (between 0 and 19.77 mmol/L) or constant (1.20 mmol/L) concentrations of contrast agent. The vials of constant concentration were used for measurement of coil non-uniformity. The vials of different concentrations were used for the measurement of the maximum linear relationship between SI and concentration and the effect of a phase-encoding scheme on the linearity, where the squared correlations (R2) between the corrected SI and the concentration were equal to 0.95 and 0.99. The results showed that the linear relationship between SI and concentration was dependent on the phase-encoding scheme and on the TIs. The results also showed that the maximum linearity with the linear phase-encoding acquisition was higher than that with the center out phase-encoding acquisition at the same R2. This study shows that the phase-encoding scheme is an important parameter when the SI is measured. These schemes can have an effect on the maximum linearity between SI and concentration.

Mesh:

Substances:

Year:  2014        PMID: 24500244     DOI: 10.1007/s12194-014-0260-7

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  14 in total

1.  Effects of inversion and saturation times on relationships between contrast agent concentrations and signal intensities of T1-weighted magnetic resonance images.

Authors:  Mahmood Nazarpoor
Journal:  Radiol Phys Technol       Date:  2010-02-27

2.  Cerebral hemodynamics and cerebral blood volume: MR assessment using gadolinium contrast agents and T1-weighted Turbo-FLASH imaging.

Authors:  B L Dean; C Lee; J E Kirsch; V M Runge; R M Dempsey; L C Pettigrew
Journal:  AJNR Am J Neuroradiol       Date:  1992 Jan-Feb       Impact factor: 3.825

3.  Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths.

Authors:  Martin Rohrer; Hans Bauer; Jan Mintorovitch; Martin Requardt; Hanns-Joachim Weinmann
Journal:  Invest Radiol       Date:  2005-11       Impact factor: 6.016

4.  Dynamic T1 measurement using snapshot-FLASH MRI.

Authors:  A Jivan; M A Horsfield; A R Moody; G R Cherryman
Journal:  J Magn Reson       Date:  1997-07       Impact factor: 2.229

Review 5.  Contrast agents for cerebral perfusion MR imaging.

Authors:  E C Unger; K Ugurbil; R E Latchaw
Journal:  J Magn Reson Imaging       Date:  1994 May-Jun       Impact factor: 4.813

6.  Quantification of myocardial perfusion with FAST sequence and Gd bolus in patients with normal cardiac function.

Authors:  J P Vallée; F Lazeyras; L Kasuboski; P Chatelain; N Howarth; A Righetti; D Didier
Journal:  J Magn Reson Imaging       Date:  1999-02       Impact factor: 4.813

7.  Influence of bolus volume and dose of gadolinium chelate for first-pass myocardial perfusion MR imaging studies.

Authors:  E Canet; P Douek; M Janier; K Bendid; J Amaya; P Millet; D Revel
Journal:  J Magn Reson Imaging       Date:  1995 Jul-Aug       Impact factor: 4.813

8.  Quantification of gadolinium-DTPA concentrations for different inversion times using an IR-turbo flash pulse sequence: a study on optimizing multislice perfusion imaging.

Authors:  T Fritz-Hansen; E Rostrup; P B Ring; H B Larsson
Journal:  Magn Reson Imaging       Date:  1998-10       Impact factor: 2.546

9.  Does gadolinium-diethylene triamine pentaacetic acid enhanced MRI of kidney represent tissue concentration of contrast media in the kidney? In vivo and in vitro study.

Authors:  M Takeda; Y Katayama; T Tsutsui; T Komeyama; T Mizusawa
Journal:  Magn Reson Imaging       Date:  1994       Impact factor: 2.546

10.  Comparison of maximum signal intensity of contrast agent on t1-weighted images using spin echo, fast spin echo and inversion recovery sequences.

Authors:  Mahmood Nazarpoor; Masoud Poureisa; Mohammad Hossein Daghighi
Journal:  Iran J Radiol       Date:  2012-12-27       Impact factor: 0.212

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.