Literature DB >> 20693612

A feasibility study using radiochromic films for fast neutron 2D passive dosimetry.

Samuel L Brady1, Rathnayaka Gunasingha, Terry T Yoshizumi, Calvin R Howell, Alexander S Crowell, Brent Fallin, Anton P Tonchev, Mark W Dewhirst.   

Abstract

The objective of this paper is threefold: (1) to establish sensitivity of XRQA and EBT radiochromic films to fast neutron exposure; (2) to develop a film response to radiation dose calibration curve and (3) to investigate a two-dimensional (2D) film dosimetry technique for use in establishing an experimental setup for a radiobiological irradiation of mice and to assess the dose to the mice in this setup. The films were exposed to a 10 MeV neutron beam via the (2)H(d,n)(3)He reaction. The XRQA film response was a factor of 1.39 greater than EBT film response to the 10 MeV neutron beam when exposed to a neutron dose of 165 cGy. A film response-to-soft tissue dose calibration function was established over a range of 0-10 Gy and had a goodness of fit of 0.9926 with the calibration data. The 2D film dosimetry technique estimated the neutron dose to the mice by measuring the dose using a mouse phantom and by placing a piece of film on the exterior of the experimental mouse setup. The film results were benchmarked using Monte Carlo and aluminum (Al) foil activation measurements. The radiochromic film, Monte Carlo and Al foil dose measurements were strongly correlated, and the film within the mouse phantom agreed to better than 7% of the externally mounted films. These results demonstrated the potential application of radiochromic films for passive 2D neutron dosimetry.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20693612      PMCID: PMC3730278          DOI: 10.1088/0031-9155/55/17/007

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  19 in total

1.  Post-irradiation colouration of Gafchromic EBT radiochromic film.

Authors:  Tsang Cheung; Martin J Butson; Peter K N Yu
Journal:  Phys Med Biol       Date:  2005-10-04       Impact factor: 3.609

2.  Characterization and real-time optical measurements of the ionizing radiation dose response for a new radiochromic medium.

Authors:  Alexandra Rink; I Alex Vitkin; David A Jaffray
Journal:  Med Phys       Date:  2005-08       Impact factor: 4.071

3.  Suitability of radiochromic medium for real-time optical measurements of ionizing radiation dose.

Authors:  Alexandra Rink; I Alex Vitkin; David A Jaffray
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

4.  The calibration of experimental self-developing Gafchromic HXR film for the measurement of radiation dose in computed tomography.

Authors:  K R Gorny; S L Leitzen; M R Bruesewitz; J M Kofler; N J Hangiandreou; C H McCollough
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

5.  Precautions and strategies in using a commercial flatbed scanner for radiochromic film dosimetry.

Authors:  L Paelinck; W De Neve; C De Wagter
Journal:  Phys Med Biol       Date:  2006-12-18       Impact factor: 3.609

6.  Dose and energy dependence of response of Gafchromic XR-QA film for kilovoltage x-ray beams.

Authors:  O Rampado; E Garelli; S Deagostini; R Ropolo
Journal:  Phys Med Biol       Date:  2006-05-24       Impact factor: 3.609

7.  Absorption spectroscopy of EBT model GAFCHROMIC film.

Authors:  Slobodan Devic; Nada Tomic; Zhiyu Pang; Jan Seuntjens; Ervin B Podgorsak; Christopher G Soares
Journal:  Med Phys       Date:  2007-01       Impact factor: 4.071

Review 8.  New developments in radiochromic film dosimetry.

Authors:  C G Soares
Journal:  Radiat Prot Dosimetry       Date:  2006       Impact factor: 0.972

9.  Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance.

Authors:  Martina Fuss; Eva Sturtewagen; Carlos De Wagter; Dietmar Georg
Journal:  Phys Med Biol       Date:  2007-06-18       Impact factor: 3.609

10.  Accurate dosimetry with GafChromic EBT film of a 6 MV photon beam in water: what level is achievable?

Authors:  L J van Battum; D Hoffmans; H Piersma; S Heukelom
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

View more
  1 in total

1.  Specific issues in small animal dosimetry and irradiator calibration.

Authors:  Terry Yoshizumi; Samuel L Brady; Mike E Robbins; J Daniel Bourland
Journal:  Int J Radiat Biol       Date:  2011-10       Impact factor: 2.694

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.